Development of new fully restrained bolted bracket moment connections for strong joints

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Recently, the Double Shear Bolted Brackets (DSBB) moment connection with four-bolt configuration has been introduced as a new fully restrained moment connection for use in shallow beam-column joints. With regards to deep beam connections, it is a requirement to have stiffer and stronger connections in the DSBB connection group. Knowing that similar code-qualified bolted bracket connections, Kaiser Bolted Bracket (KBB) connections, have marginal rotational stiffness, they cannot be considered as a fully restraint moment connection in deep beam-to-column joints. Therefore, in this discourse, six-bolt and eight-bolt configurations of DSBB are developed and their design methodology is outlined. Less thickness of bracket components, less diameter of bolts used, and greater stiffness compared to KBB code-qualified (AISC 358-16 standard) connections by the (KBB connection) are the main advantages of these new connections, making them a more applicable option of fully restrained connections for deep beam joints than their counterpart KBB connection. First, the DSBB design method is developed considering all possible limit states of buckling, yield, and rupture failures for the plate components of each bracket. Then, by using a validated high fidelity finite element study, the cyclic performance of DSBB connections is obtained and successfully accepted based on the AISC 341-16 standard requirements for fully restrained connections in special moment connections. The results indicated the low risk of failure and proper relaxed stress distribution around the connection compared to the corresponding KBB connection. In addition, the material consumption of DSBB six-bolt and eight-bolts were 19.7% and 6.9% in bolts and were 19.9% and 42.9% in brackets less than that of the corresponding KBB connections. Finally, it is concluded that DSBB six-bolt and eight-bolt configurations are efficient choices of fully restrained moment connections for application in deep beam-column joints.
Rocznik
Strony
159--188
Opis fizyczny
Bibliogr. 20 poz., rys., wykr.
Bibliografia
  • [1] Mahin SA. Lessons from damage to steel buildings during the Northridge earthquake. Eng Struct. 1998;20(4–6):261–70.
  • [2] Khalili M, Sivandi-Pour A, Farsangi EN. Experimental and numerical investigations of a new hysteretic damper for seismic resilient steel moment connections. J Build Eng. 2021;102811.
  • [3] ANSI/AISC 341-16. Seismic provisions for structural steel buildings. Chicago: American Institute of Steel Construction (AISC); 2016.
  • [4] ANSI/AISC 360-16. Specification for structural steel buildings. Chicago: American Institute of Steel Construction; 2016.
  • [5] ANSI 358s-18. Prequalified connections for special and intermediate steel moment frames for seismic applications. Chicago: American Institute of Steel Construction (AISC).
  • [6] Adan SM, Gibb W. Experimental evaluation of kaiser bolted bracket steel moment-resisting connections. Eng J Am Inst Steel Constr INC. 2009;46(3):181–95.
  • [7] Kasai K, Bleiman D. January. Bolted brackets for repair of damaged steel moment frame connections. In: 7th US-Japan workshop on the improvement of structural design and construction practices: lessons learned from Northridge and Kobe. 1996.
  • [8] Abar BM, Ghobadi MS. Double shear bolted bracket moment connections part 1: our-bolt configuration design methodology. J Constr Steel Res. 2020;174:106280.
  • [9] Abar BM, Ghobadi MS, Jazany RA. Double shear bolted bracket moment connections, part 2: Four-bolt configuration response evaluation. J Constr Steel Res. 2020;174:106281.
  • [10] ABAQUS FEA. Analysis User’s Manual 6.14. Dassault Systemes Simulia Corp., Providence, RI. 2011.
  • [11] RCSC (Research Council on Structural Connections). Specification for structural joints using high-strength bolts. 2009.
  • [12] Sumner EA. Unified design of extended end-plate moment connections subject to cyclic loading. Doctoral dissertation, Virginia Tech. 2003.
  • [13] Zhang Y, Wang P, Liu M, Liu Y, Zhang B, Zhou S, Chen J. Numerical studies on yield line patterns of thread-fixed one-side bolted endplate connection to square hollow section column under tension. J Constr Steel Res. 2020;173:106262.
  • [14] Salmon CG, Johnson JE, Malhas FA. Steel structures: design and behavior emphasizing LRFD. 2008.
  • [15] ATC. Guidelines for cyclic seismic testing of components of steel structures. ATC-24, Applied Technology Council, Redwood City, CA. 1992.
  • [16] Masud M, Chen H, Wang J, Sawab J, Mo YL, Hsu TT. High-fidelity finite element simulation of non-contact splices in column-drilled shaft connections. Eng Struct. 2021;239:112186.
  • [17] Qian J, Yu H, Yan F, Dong H, Li J, Liu Y. Experimental study on full-scale steel beam-to-column moment connections. Earthq Eng Eng Vib. 2005;4(2):311–23.
  • [18] Mehr SMRF, Ghobadi MS. Seismic performance of retrofitted WFP connections joined to box column using ribs. J Constr Steel Res. 2017;137:297–310.
  • [19] Ghobadi MS, Jazany RA. Seismic demand assessment of code-designed continuity plate in panel zone. Bull Earthq Eng. 2019;17(2):891–926.
  • [20] El-Tawil S, Vidarsson E, Mikesell T, Kunnath SK. Inelastic behavior and design of steel panel zones. J Struct Eng. 1999;125(2):183–93.