Powiadomienia systemowe
- Sesja wygasła!
- Sesja wygasła!
- Sesja wygasła!
- Sesja wygasła!
Tytuł artykułu
Treść / Zawartość
Pełne teksty:
Identyfikatory
Warianty tytułu
Czynniki determinujące jakość muru – różnicowanie wytrzymałości i niezawodności
Języki publikacji
Abstrakty
A house or any other building without walls is truly hard to imagine. The first thing usually associated with walls is, of course, masonry. Today, masonry walls perform a load-bearing function in buildings up to four above-ground floors, in the higher parts of the buildings they perform a protective and stiffening function. However, there is a widespread opinion that the designer does not have to check the bearing capacity of masonry structures because masonry are were stand, are standing and will stand. Not everyone, however, currently works the wall as it should. The problem is that a lot of emphasis is now placed on reducing construction times. Therefore, there are a number of factors affecting the quality of the masonry structure, which overall reduce their safety. The article presents the influence of the quality of masonry on the differentiation of bearing capacity and reliability of an example masonry structure. The analyses included various values γm of the partial factor, recommended in the national annex PN-EN 1996-1, depending on the category of masonry units, class execution of works and type of mortar. In addition, a decrease in load capacity and reliability caused by the increase of the initial eccentric resulting from the inaccuracy of the masonry wall was examined.
Ciężko wyobrazić sobie dom, budynek bez ścian. Jeżeli myślimy o ścianach, to pierwszym skojarzeniem są mury. Dziś mury pełnią funkcję nośną w budynkach do czterech kondygnacji nadziemnych, w wyższych partiach budynków pełnią funkcję osłonową i usztywniającą. Powszechnie panuje jednak jeszcze opinia, że konstruktor nie musi sprawdzać nośności konstrukcji murowych ponieważ mury stały, stoją i stać będą. Nie każdy jednak obecnie mur pracuje tak, jak powinien. Problem polega na tym, że obecnie duży nacisk kładzie się na skrócenie czasu wznoszenia budynków. W związku z tym pojawia się szereg czynników wpływających na jakość wykonania konstrukcji murowej, które sumarycznie wpływają na zmniejszenie ich bezpieczeństwa. W artykule przedstawiono wpływ jakości wykonania muru na różnicowanie nośności i niezawodności przykładowej konstrukcji murowej. W analizach uwzględniono różne wartości współczynnika bezpieczeństwa, rekomendowanego w załączniku krajowym PN-EN 1996-1 [1], uzależnione od kategorii elementów murowych, klasy robót murarskich oraz rodzaju zaprawy. Ponadto zbadano spadek nośności i niezawodności spowodowany zwiększeniem mimośrodu początkowego wynikającego z niedokładności wykonania ściany murowanej.
Czasopismo
Rocznik
Tom
Strony
139--152
Opis fizyczny
Bibliogr. 18 poz., fig., tab.
Twórcy
autor
- Department of Building Structures, Faculty of Civil and Environmental Engineering and Architecture; Rzeszow University of Technology, 2 Poznańska Street, Rzeszow 35-084; Poland
autor
- Department of Building Structures, Faculty of Civil and Environmental Engineering and Architecture; Rzeszow University of Technology, 2 Poznańska Street, Rzeszow 35-084; Poland
autor
- Department of Building Structures, Faculty of Civil Engineering Environmental Engineering and Architecture; Rzeszow University of Technology; 2 Poznańska Street; Rzeszow 35-084; Poland
Bibliografia
- 1. EN 1996-1-1:2004 Eurocode 6: Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures. 2004 CEN.
- 2. Stewart M.G., Lawrence S.J., “Model Error, Structural Reliability and Partial Safety Factors for Structural Masonry in Compression”, Masonry International, vol. 20, no. 3, 2007, pp. 107-116.
- 3. Drobiec Ł., Jasiński R., Piekarczyk A., Masonry structures according to Eurocode 6 and related standards. PWN, vol. 2, Warsaw, 2013.
- 4. EN 1996-1-2:2005 Eurocode 6: Design of masonry structures - Part 1-2: General rules - Structural fire design. 2005 CEN
- 5. EN 1996-2:2006 Eurocode 6: Design of masonry structures - Part 2: Design considerations, selection of materials and execution of masonry. 2006 CEN.
- 6. EN 1996-3:2006 Eurocode 6: Part 3: Simplified calculation methods for unreinforced masonry structures. 2006 CEN.
- 7. EN 771-1:6, Specification for masonry units. 2005 CEN.
- 8. Buda Ożóg L., Skrzypczak I., Szylak K., Raczak A., Masonry constructions – examples of calculations according to Eurocode 6 and probabilistic methods. Rzeszow University of Technology Publishing House, Rzeszow, 2017.
- 9. Rybarczyk T., „Czynniki wpływające na wytrzymałość muru na ściskanie”, Materiały Budowlane, vol. 4, 2016, pp. 74-77. https://doi.org/ 10.15199/33.2016.04.20
- 10. EN 1990:2002 Eurocode – Basis of structural design. 2002 CEN.
- 11. PN-ISO 2394: General principles of reliability of building structures. 2010 CEN.
- 12. Woliński Sz., Fundamentals of Designing Structures in General Construction. PWN, vol. 3, Warszawa, 2011, pp. 112-146.
- 13. Woliński Sz., “Calibration of partial coefficients for existing structures”, Scientific Notebooks PRz, 2011.
- 14. Nowak A., Collins K., Reliability of Structures. CRC Press, 2012.
- 15. Holicky M., Markova J., “Verification of load factors for concrete components by reliability and optimization analysis: Background documents for implementing Eurocodes”, Progress in Structural Engineering and Materials, vol. 2, no. 4, 2000, pp. 502-507.
- 16. Holicky M., Retief J. V., “Reliability assessment of alternative Eurocode and South African load combination schemes fot structural design”, Journal of and South African Institution of Civil Engineering, vol. 47, no. 1, (January 2005), pp. 15-20.
- 17. EN 772-1, Methods of test for masonry units -Part 1: Determination of compressive strength. 2005 CEN.
- 18. Ćwierz J., Cinal W., Kampczyk A., Measurement of deviations of the building facade walls from the vertical plane. https://doi.org/10.17512/znb.2016.1.04
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2020).
Typ dokumentu
Bibliografia
Identyfikator YADDA