The paper deals with economical aspects concerning the quality control of concrete. About 70% of total concrete production is connected with the structural concrete, the subject of quality control and/or conformity. When checking the conformity criteria for a compressive strength of concrete for a small number of samples, qualification errors do not affect the formation of costs associated with losses on external deficiencies. In order to avoid costs related to qualification errors and losses on external deficiencies, the number of samples should be set larger than the minimum (included in contract’s clauses). Furthermore, the designer recommendations should be indicated in the specification. In the paper the costs concerning quality control for concrete have been analyzed.
Czasopismo
Rocznik
Tom
Strony
49--56
Opis fizyczny
Bibliogr. 16 poz., fig., tab.
Twórcy
autor
- Faculty of Civil Engineering, Environmental Protection and Architecture, Rzeszow University of Technology
autor
- Faculty of Civil Engineering and Architecture, Lublin University of Technology
Bibliografia
- [1] EN 206-1:2013, Concrete – Part 1: Specification, performance, production and conformity.
- [2] Holicky, M., Vorlicek. M., Fractile estimation and sampling inspection in building, Acta Polytechnica, CVUT Praha, 1992.Vol. 32. Issue 1, 87-96.
- [3] Sual I. Gass, and Arjang A. Assad, An annotated timeline of operation research. An informal history. Springer Science and Business Media, 2005.
- [4] Harrison. T.A., Crompton, S., Eastwood. C., Richardson. G., Sym, R., Guidance on the application of the EN 206-1 conformity rules, Quarry Products Association, 2001.
- [5] Czarnecki, L. et al., Concrete according to PN EN 206-1- The comment – Collective work, Polish Cement and PKN, Cracow, Poland, 2004.
- [6] Lynch, B., Kelly, J., McGrath, M., Murphy, B., Newell, J., The new Concrete Standards, An Introduction to EN 206-1, The Irish Concrete Society, 2004.
- [7] Montgomery, D.C., Introduction to Statistical Quality Control, 5th Ed., Wiley, 2005.
- [8] Taerwe, L., Evaluation of compound compliance criteria for concrete strength, Materials and Structures, 1998, 21, pp. 13-20.
- [9] Catarino, J.M.R., Statistical criteria for acceptance of materials performance of concrete standards ENV 206;1993 and prEN206:1997. Proceedings of 12th ERMCO Congress, Vol. 1, Lisbon, 1998.
- [10] Brunarski, L., The mathematical basis for shaping the strength of materials conformity criteria, Scientific Work of the Institute of Building Technology, Publishing of the Institute of Building Technology, Warsaw 2009 (in Polish).
- [11] Szczygielska, E., Tur, V., The study of the conformity criterion for compressive strength of concrete based on order statistics, Civil Engineering and Architecture, 2013, Vol. 12, Issue 3, 223-230.
- [12] Taerwe, L., Caspeele, R., Conformity control of concrete: some basic aspects, Proceedings of 4-th International Probabilistic Symposium, Ghent, Belgium, 2006, 57-70.
- [13] Skrzypczak, I., Analysis of criteria of quality assessment for concrete and their influence on risk of the producer and the recipient, The Publisher of the Rzeszow University of Technology,, Rzeszow, Poland, 2013 (in Polish).
- [14] Evans, J., Lindsay, W., The Management and Control of Quality, West Publishing Company, 1989.
- [15] Banovac, E., Pavlovic, D., Vistica N., Mathematical aspects of acceptance sampling procedure. International Journal of Mathematical Models and Methods in Applied Sciences, 2012, Issue 5, Vol. 6, 625-633.
- [16] Dumicic, K., Bahovec, V., Kurnoga Zivadinovic, N., Studying an OC Curve of an Acceptance Sampling Plan: A Statistical Quality Control Tool, Proceedings of the 7th WSEAS International Conference on Mathematics & Computers in Business & Economics, Cavtat, Croatia, 2006, 1-6.
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-f4275f8a-79d9-401d-875f-30955f3f1ec0