PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Wiek wody w sieci wodociągowej jako czynnik ryzyka zdrowotnego związanego ze zbiorowym zaopatrzeniem w wodę

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The correct operation of collective water supply system requires continuous monitoring of water quality at various stages (collection, treatment, pumping and distribution). An important parameter associated with water quality is water age – the time from the moment of pumping the water into water supply system to its collection by people. In the case of water contamination at the exit of the water treatment plant, water age is exual to contamination time spread in the water supply network. The length of contamination time spread determines how many people will be affected by the bad water quality which can affect health or life. The paper presents a methodology for determining the risks associated with the appearance of water contamination using hydraulic model, as well as application case for selected collective water supply system.
PL
Poprawna eksploatacja systemu zbiorowego zaopatrzenia w wodę wymaga ciągłego monitoringu jakości wody na różnych etapach (ujmowania, uzdatniania, pompowania, dystrybucji). Istotnym parametrem związanym z jakością wody jest wiek wody, czyli czas od momentu wpompowania wody do sieci wodociągowej do jej pobrania przez odbiorców. W przypadku skażenia wody na wyjściu ze stacji uzdatniania wody wiek wody jest tożsamy z czasem rozprzestrzeniania się zanieczyszczenia w sieci wodociągowej. Od długości czasu rozprzestrzeniania zależy, ile osób korzystających z wodociągu będzie narażonych za spożycie wody o jakości zagrażającej zdrowiu lub życiu. W pracy przedstawiono metodykę określania ryzyka związanego z pojawieniem się w sieci wodociągowej zanieczyszczonej wody wykorzystującą model hydrauliczny, a także przykład aplikacyjny dla wybranego systemu zbiorowego zaopatrzenia w wodę.
Rocznik
Strony
33--43
Opis fizyczny
Bibliogr. 21 poz., wykr., rys., tab.
Twórcy
autor
  • Department of Water Supply and Sewage Disposal, Rzeszow University of Technology, al. Powstańców Warszawy 12, 35–959 Rzeszów, Poland, phone: +48 17 865 14 27
Bibliografia
  • [1] Szpak D, Tchórzewska-Cieślak B. Analysis and assessment of the security method against incidental contamination in the collective water supply system, J Konbin. 2015;2:49-58. DOI: 10.1515/jok-2015-023.
  • [2] Rak J, Boryczko K. The Issue of Water Resources Diversification in Water Supply Systems. J Konbin. 2015;35:157-168. DOI: 10.1515/jok-2015-0049.
  • [3] Piegdoń I, Tchórzewska-Cieślak B. The Use of Fuzzy Set Theory in Exploitation Management Process on the Water Supply Network. J Konbin. 2015;35:109-118. DOI: 10.1515/jok-2015-0044.
  • [4] Zimoch I, Szymura E, Moraczewska-Majkut K. Event tree analysis application in industrial object exploitation safety. Chem Industry. 2015;94:196-200. DOI: 10.15199/62.2015.2.13.
  • [5] Tchórzewska-Cieślak B. Fuzzy Model for Failure Risk in Water-pipe Networks Analysis. Ochr Środ. 2011;33:35-40. www.os.not.pl/docs/czasopismo/2011/1-2011/Tchorzewska_1-2011.pdf.
  • [6] Sadiq R, Rodriguez M, Imran SA, Najjaran H. Communicating human health risks associated with disinfection byproducts in drinking water supplies: a fuzzy-based approach. Stoch Environ Res Risk Assess. 2007;21:341-353. www.link.springer.com/content/pdf/10.1007%2Fs00477-006-0069-y.pdf.
  • [7] Sadiq R, Kleiner Y, Rajani B. Water quality failures in distribution networks-risk analysis using fuzzy logic and evidentail reasoning. Risk Anal. 2007;27:1381-1394. www.onlinelibrary.wiley.com/doi/10.1111/j.1539-6924.2007.00972.x/epdf.
  • [8] Boryczko K, Piegdoń I, Eid M. Collective water supply systems risk analysis model by means of RENO software: Safety, Reliability and Risk Analysis: Beyond the Horizon. London: Taylor Francis Group, 2014, pp. 1987-1992.
  • [9] Boryczko K, Tchórzewska-Cieślak B. Analysis of risk of failure in water main pipe network and of developing poor quality water. Environ Prot Eng. 2014;40:77-92. DOI: 10.5277/epe140407.
  • [10] Lindhe A, Norberg T, Rosen L. Approximate dynamic fault tree calculations for modelling water supply risks. Reliab Eng Syst Safe. 2012;106:61-71. DOI: 10.1016/j.ress.2012.05.003.
  • [11] Khan F, Ferdous R, Sadiq R, Amyotte P, Veitch B. Fault and Event Tree Analyses for Process Systems Risk Analysis: Uncertainty Handling Formulations. Risk Anal. 2011;31:86-107. DOI: 10.1111/j.1539-6924.2010.01475.
  • [12] Petkovic S, Gregoric E, Slepcevic V, Blagojevic S, Gajic B, Kljujev I, et al. Contamination of local water supply systems in suburban Belgrade. Urban Water J. 2011;8:79-92. DOI: 10.1080/1573062x.2010.546862.
  • [13] Debon A, Carrion A, Cabrera E, Solano H. Comparing risk of failure models in water supply networks using ROC curves. Reliab Eng Syst Safe. 2010;95:43-48. DOI: 10.1016/j.ress.2009.07.004.
  • [14] Dadic Z, Ujevic M, Vitale K. Integral Management of Water Resources in Croatia: Step Towards Water Security and Safety for All. Threats Food Water Chain Infrastruct. 2010;131-140. DOI: 10.1007/978-90-481-3546-2_9.
  • [15] Rabczak S, Proszak-Miasik D. Critical flow factor of refrigerants: Environmental Engineering IV. London: Taylor Francis Group, 2013, pp. 381-385.
  • [16] Szymura E, Zimoch I. Operator reliability in risk assessment of industrial systems function. Przem Chem. 2014;93:111-116. DOI:10.12916/przemchem.2014.111.
  • [17] Kowalski D, Miszta-Kruk K. Failure of water supply networks in selected Polish towns based on the field reliability tests. Eng Fail Anal. 2013;12:736-742. DOI: 10,1016/j.engfailanal. 2013.07.017.
  • [18] Bajer J. Reliability analysis of variant solutions for water pumping stations: Environmental Engineering. New York, Singapore: Taylor Francis Group, 2007, pp. 253-261.
  • [19] Tchórzewska-Cieślak B, Szpak D. A Proposal of a Method for Water Supply Safety Analysis and Assessment. Ochr Środ. 2015;37:43-47 www.os.not.pl/docs/czasopismo/2015/3-2015/Tchorzewska_3-2015.pdf.
  • [20] Haimes YY. Risk analysis of fracture and failure. Mater Res Innov. 1998;2:16-21. DOI: 10.1007/s100190050055.
  • [21] Studzinski A. Amount of labour of water conduit repair: Safety, Reliability and Risk Analysis: Beyond the Horizon. London: Taylor Francis Group, 2014, pp. 2081-2084.
Uwagi
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-f3a1b1c1-3e98-4203-9d62-4cc8d8009977
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.