Powiadomienia systemowe
- Sesja wygasła!
Identyfikatory
Warianty tytułu
Postępy w cyfrowej radiografii przemysłowej. Cz. 2, Tomografia komputerowa
Języki publikacji
Abstrakty
Part 1: Film Replacement and Backscatter Imaging. The related paper was published in Vol 1-2/2016 of this journal. Part 2: Computed tomography (CT). Applications cover the range from nano-meter to meter scale. New specialized high energy CT devices have been laid out for inspection of large building structures or complete cars before and after crash tests. The scope of typical CT applications changes from flaw detection to dimensional measurement in industry substituting coordinate measurement machines. First applications of at line or in line inspection in production lines of car industry are discussed. CT is applied for a variety of applications, where selected areas as e.g. plant and food research in outlined. Mobile computed tomography is applied for in-service radiographic crack detection and sizing of welded pipes in nuclear power plants and for NDT of large CFRP structures of airplanes. Part 3: Micro Radiography and Micro CT. To be published in this journal.
Podobnie jak w przypadku zakończonego sukcesem wdrożenia fotografii cyfrowej, bardzo istotne zmiany można zaobserwować także w cyfrowej radiologii przemysłowej. Niniejsza praca jest podzielona na 3 części: Część 1: Następca błony radiograficznej i obrazowanie za pomocą rozproszenia wstecznego – publikacja ukazała się w wydaniu Nr1-2/2016 tego czasopisma. Część 2: Tomografia komputerowa (CT). Zastosowania tomografii obejmują obiekty o wielkości od nanometrów do metrów. Nowe dedykowane urządzenia wysokoenergetycznej tomografii komputerowej skonstruowano w celu inspekcji dużych konstrukcji budowlanych czy też całych samochodów przed i po testach zderzeniowych. Cel typowego zastosowania tomografii komputerowej uległ zmianie z detekcji wad na wymiarowanie wyrobów przemysłowych, co spowodowało zastąpienie współrzędnościowych maszyn pomiarowych. W pierwszej kolejności omówiono zastosowanie tomografii komputerowej na liniach produkcyjnych w przemyśle samochodowym. Tomografia komputerowa ma wiele zastosowań, w tym np. badanie roślin i żywności. Przenośne tomografy komputerowe wykorzystywane są do wykrywania defektów i wymiarowania spawanych rur w elektrowniach jądrowych, a także do inspekcji dużych elementów konstrukcji lotniczych wykonanych z kompozytów węglowych. Część 3: Mikroradiografia i mikrotomografia komputerowa.
Czasopismo
Rocznik
Tom
Strony
7--14
Opis fizyczny
Bibliogr. 28 poz., rys.
Twórcy
autor
- BAM Bundesanstalt für Materialforschung und –prüfung, Germany
autor
- Fraunhofer Development Center X-ray Technology, Germany
Bibliografia
- [1] Kastner, 6th Conference on Industrial Computed Tomography (ICT ), 9th – 12th February 2016, Wels, Austria, http://www.ndt.net/article/ctc2016/papers/preface.pdf.
- [2] A. Chahbaz and R. Sicard, Comparitive Evaluation between Ultrasonic Phased Array and Synthetic Aperture Focusing Techniques, AIP Conference Proceedings, Volume 657, Issue 1, 10.1063/1.1570213, 2003, http://aip.scitation.org/doi/abs/10.1063/1.1570213.
- [3] D. Fratzscher, J. Beckmann, L. Von Chrzanowski, U. Ewert, Computed THz – Tomography, 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa, http://www.ndt.net/article/wcndt2012/papers/291_wcndtfinal00291.pdf.
- [4] U. Ewert, Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2009, December 10-12, 2009, Tiruchirappalli, India, http://www.ndt.net/article/ndeindia2009/pdf/31-Evert.pdf.
- [5] VDI/VDE 2630 – 1.1 Computed Tomography in dimensional measurement - Basics and Definitions (2009), https://www.vdi.de/uploads/tx_vdirili/pdf/1473751.pdf
- [6] VDI/VDE 2630 – 1.2 Computed Tomography in dimensional measurement - Influencing variables on measurement results and recommendations for computed tomography dimensional measurements (2010), https://www.vdi.de/uploads/tx_vdirili/pdf/1671067.pdf
- [7] VDI /VDE 2630 – 1.3 / VDI /VDE 2617 – 13 Computed Tomography in dimensional measurement -Guideline for the application of EN ISO 10360 for coordinate measuring machines with CT sensors (2011) https://www.vdi.de/uploads/tx_vdirili/pdf/1804694.pdf , VDI /VDE 2630 – 1.4 Computed Tomography in dimensional metrology – Measurement procedure and comparability (2010), https://www.vdi.de/uploads/tx_vdirili/pdf/1571040.pdf
- [8] VDI/VDE 2630 – 2.1 Computed Tomography in dimensional measurement - Determination of uncertainty of measurement and the test process suitability of coordinate measurement systems with CT sensors (2015), https://www.vdi.de/uploads/tx_vdirili/pdf/2283256.pdf.
- [9] O. Brunke, F. Hansen, I. Stuke, F. F. Butz, A new Concept for High-Speed at-line and in-line-CT for up to 100% Mass Production Process Control, 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa, http://www.ndt.net/article/wcndt2012/papers/460_wcndtfinal00460.pdf.
- [10] S. Oeckl, Th. Kondziolka: Gussfehler genau orten Artikel QZ - Qualität und Zuverlässigkeit, Nr. 9, 2014, Jg. 59, Seiten:56 - 57; Herausgeber: Deutsche Gesellschaft für Qualität e.V., Frankfurt, Verlag: Carl Hanser Verlag, München.
- [11] Holger Schnell, PhD thesis, University Erlangen-Nurnberg, 2011.
- [12] A. Eggert, M. Müller, F. Nachtrab, J. Dombrowski, A. Rack, S. Zabler, High-speed in-situ tomography of liquid protein foams International Journal of Materials Research, July, Vol. 105, Nr. 7, pp 632-639.
- [13] Masurements performed at the EZRT laboratory at the University of Würzburg, in close collaboration with the chair for X-ray microscopy LRM.
- [14] Precious guitar, MI 58, Germanisches Nationalmuseum, Nürnberg, Germany.
- [15] Th. Fuchs, R. Wagner, Ch. Kretzer, R. Schielein, G. Scholz, M. Zepf, F. Bar, S. Kirsch, M. Wolters-Rosbach, Development of a Standard for Computed Tomography of Historical Musical Instruments - the MUSICES project, 19th World Conference on Non-Destructive Testing, Munich 2016, http://www.ndt.net/article/wcndt2016/papers/mo2c4.pdf.
- [16] Quality assurance of radioactive waste packages by computerized tomography, Task 3 Characterization of radioactive waste forms A series of final reports (198589) No 37, http://bookshop.europa.eu/de/quality-assurance-of-radioactive-waste-packages-by-computerized-tomography-task-3-pbCDNA 13879/.
- [17] High energy CT image by VJ Technologies, http://vjt.com/vjt/technologies/high-energy-dr-ct.
- [18] U. Ewert, K. Thiessenhusen, A. Deresch, C. Bellon, S. Hohendorf, S. Kolkoori, N. Wrobel, B. Redmer, Reconstruction Methods for Coplanar Translational Laminography Applications, Digital Industrial Radiology and Computed Tomography (DIR 2015), 22-25 June 2015, Belgium, Ghent, http://www.ndt.net/events/DIR 2015/app/content/Slides/96_Ewert.pdf.
- [19] C. Schorr, M. Maisl, Ray-Length-Based ROI -Correction for Computed Laminography, 5th Conference on Industrial Computed Tomography (iCT ) 2014, 25-28 February 2014, Wels, Austria, http://www.ndt.net/article/dgzfp2014/papers/di2a3.pdf.
- [20] Baysian CT reconstruction with a priory knowledge, Eigenor, https://www.eigenor.com/products/x-ray-tomography
- [21] 3D reconstruction and 3D visualization, different algorithms inclusive FBP and ART, Volume Graphics, http://www.volumegraphics.com/de/.
- [22] U. Ewert, B. Redmer, C. Rädel, U. Schnars, R. Henrich, K. Bavendiek, M. Jahn, “Mobile Computed Tomography for Inspection of Large Stationary Components in Nuclear and Aerospace Industries”, Materials Transactions, Vol. 53, No. 2 (2012) pp. 308 to 310.
- [23] U. Ewert, B. Redmer, D. Walter, K. Thiessenhusen, C. Bellon, P. Nicholson, A. Clarke, K. Finke-Harkonen, J. Scharfschwerdt, K. Rohde, X-Ray Tomographic In-Service-Testing of Circumferential Pipe Welds - The European Project TomoWELD, 19th World Conference on Non-Destructive Testing (WCNDT 2016), 13-17 June 2016 in Munich, Germany, http://www.ndt.net/article/wcndt2016/papers/we3d5.pdf.
- [24] D. Walter, U. Zscherpel, U. Ewert, Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications, 19th World Conference on Non-Destructive Testing (WCNDT 2016), 13-17 June 2016 in Munich, Germany, http://www.ndt.net/article/wcndt2016/papers/tu2b5.pdf.
- [25] ISO 17636-2, Non-destructive testing of welds – Radiographic testing - Part 2: X- and gamma-ray techniques with digital detectors (2013), Beuth-Verlag.
- [26] Uwe Ewert, Bernhard Redmer, David Walter, Kai-Uwe Thiessenhusen, Carsten Bellon, P. Ian Nicholson, Alan L. Clarke, Klaus-Peter Finke-Harkonen, X-Ray Tomographic In-Service inspection of Girth Welds – The European Project TomoWELD, QNDE , 41st Review of Progress in Quantitative Nondestructive Evaluation, Proceedings of Conference, Boise, Idaho, USA, July 20-25, 2014, No. 525.
- [27] X-ray tube design: RTW RÖNTGEN - TECHNIK DR . WARRIKHOFF KG , http://www.rtwxray.de.
- [28] O. Bullinger, U. Schnars, D. Schulting, B. Redmer, M. Tschaikner, U. Ewert, Laminographic Inspection of Large Carbon Fibre Composite Aircraft-Structures at Airbus, 19th World Conference on Non-Destructive Testing (WCNDT 2016), 13-17 June 2016 in Munich, Germany, http://www.ndt.net/article/wcndt2016/papers/we1i3.pdf.
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-f39a307b-ce76-491c-84b3-2ec76728c535