Analiza synchronizowanego generatora asynchronicznego dla wiatrowej instalacji elektrycznej
Języki publikacji
Abstrakty
Objective. Analysis of the effectiveness of the use of SAG, excited according to a fundamentally new scheme, in a wind electric installation. This article analysis the application of the efficiency of a synchronized asynchronous generator in a wind electric installation. This is natural in vibration damping, which causes gusts of wind and changes in wind speed, as well as an increase in the efficiency of the device at low wind speeds. The article shows a schematic diagram of a synchronized asynchronous generator of a wind electric installation. Some properties of the synchronized asynchronous generator that drives the circuit are also explored. The article presents the advantages of using a synchronized asynchronous generator for wind turbines. The results of calculated characteristics for the given system of values are given. The possibility of operation at cosφ =1 is considered.
Cel. Analiza efektywności wykorzystania SAG, wzbudzonego według zasadniczo nowego schematu, w wiatrowej instalacji elektrycznej. W artykule dokonano analizy zastosowania sprawności zsynchronizowanego generatora asynchronicznego w elektrowni wiatrowej. Jest to naturalne przy tłumieniu drgań, które powoduje podmuchy wiatru i zmiany prędkości wiatru oraz wzrost wydajności urządzenia przy małych prędkościach wiatru. W artykule przedstawiono schemat ideowy zsynchronizowanego generatora asynchronicznego wiatrowej instalacji elektrycznej. Badane są również niektóre właściwości zsynchronizowanego generatora asynchronicznego, który napędza obwód. W artykule przedstawiono zalety zastosowania zsynchronizowanego generatora asynchronicznego do turbin wiatrowych. Podano wyniki obliczonych charakterystyk dla zadanego systemu wartości. Rozważana jest możliwość pracy przy cosφ =1.
Wydawca
Czasopismo
Rocznik
Tom
Strony
37--40
Opis fizyczny
Bibliogr. 16 poz., rys., tab.
Twórcy
autor
- Azerbaijan State Oil and Industry University
autor
- Azerbaijan State Oil and Industry University
autor
- Azerbaijan State Oil and Industry University
Bibliografia
- [1]. Nijat, Mammadov. “Selection of the type of electric generators for a wind electric installation”. Universum journal, pp.65-67 №9(102) 022.:DOI:10.32743/UniTech.2022.102.9.14234 https://7universum.com/pdf/tech/9(102)/9(102_5).pdf
- [2]. Mammadov N.S., Ganiyeva N.A., Aliyeva G.A. “Role of Renewable Energy Sources in the World”. Journal of Renewable Energy, Electrical, and Computer Engineering. September, 2022. DOI: 10.29103/jreece.v2i2.8779 pp. 63-67 https://ojs.unimal.ac.id/jreece/issue/view/359
- [3]. Shinryo J. “Induction synchronous motor”. Mitsubishi denkigiho. 1984. Vol. 38, No. 6. P. 24-28.https://www.internauka.org/journal/science/internauka/251
- [4]. Abdulkadyrov A.I. “A new principle of synchronization of an asynchronous motor” // Elektrotekhnika. 1998. No. 4. S. 17-20.
- [5]. Abdulkadirov A.I., Kuliyev S.F. “On the effectiveness of the use of a synchronized asynchronous generator in a wind power plant” (2001). ASOA. Baku
- [6]. V.V.Shevchenko, Y.R.Kulish “Analysis of the possibility of using different types of generators for wind power plants, taking into account the power range”. Bulletin of NTU “KhPI”, № 65, pp. 107-117, Russia, 2013.
- [7]. Abdulkadyrov A.I. “On the use of a synchronized asynchronous motor to drive a drawworks” // Azerbaijan Oil Industry. 1997. No. 7. S. 28-30.
- [8]. W. Cao, Y. Xie and Z. Tan “Wind Turbine Generator Technologies”, INTECH open science/open minds, pp-44. China, 2012
- [9]. Millstein D, Solomon-Culp J, Wang M, Ullrich P, Collier C. Wind energy variability and links to regional and synoptic scale weather. Climate Dynam. 2019; 52(7-8): 4891- 4906. DOI:10.1007/s00382-018-4421-y
- [10] . Coburn J. Climatological teleconnections with wind energy in a midcontinental region. J Appl Meteorol Clim. 2021; 60(3): 305- 322. DOI:10.1175/JAMC-D-20-0203.1
- [11]. West CG, Smith RB. Global patterns of offshore wind variability. Wind Energy. 2021; 24(12): 1466- 1481. DOI:10.1002/we.2641
- [12]. Gao L, Li B, Hong J. Effect of wind veer on wind turbine power generation. Phys Fluids. 2021; 33(1):01510. DOI:10.1063/5.0033826
- [13]. Wharton S, Lundquist JK. Atmospheric stability affects wind turbine power collection. Environ Res Lett. 2012; 7(1):014005. DOI:10.1088/1748-9326/7/1/014005
- [14]. Pryor SC, Barthelmie RJ, Bukovsky MS, Leung LR, SakaguchiK. Climate change impacts on wind power generation. Nature Rev Earth Environ. 2020; 1(12): 627- 643. DOI:10.1038/s43017-020-0101-7
- [15]. H. Díaz, D. Silva, C. Bernardo, C. Guedes Soares, Micro sitting of floating wind turbines in a wind farm using a multicriteria framework, Renewable Energy, 10.1016/j.renene.2023.01.016, 204, (449-474), (2023)