Environmental Pollution Monitoring on High-Voltage Insulators

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Monitorowanie zanieczyszczenia środowiska na izolatorach wysokiego napięcia
Języki publikacji
EN
Abstrakty
EN
This work is focused on environmental pollution monitoring on selected high-voltage insulators. It is well known that environmental pollution on electrical insulation is one of the problems faced by distribution utilities and electricity transmission system. Due to this reason there is a need to deal with monitoring of environmental pollution as it strongly influences their capability to withstand the high-voltage stress without the breakdown. It is the aim of present work to explain influence of morphology and chemical composition of pollutants on the surface resistance and conductivity of selected insulators.
PL
W artykule przedstawiono wyniki prac dotyczących monitorowania zanieczyszczenia środowiska na wybranych izolatorach wysokonapięciowych. Powszechnie wiadomo, że zanieczyszczenie środowiska oddziałujące na izolację elektryczną jest jednym z problemów, z którymi borykają się przedsiębiorstwa dystrybucyjne i system przesyłu energii elektrycznej. Z tego powodu istnieje potrzeba monitorowania zanieczyszczenia środowiska które silnie wpływa na ich zdolność instalacji do pracy bez awarii. Celem niniejszego artykułu jest wyjaśnienie wpływu morfologii i składu chemicznego zanieczyszczeń na oporność powierzchni i przewodnictwo wybranych izolatorów.
Rocznik
Strony
111--114
Opis fizyczny
Bibliogr. 6 poz., rys., wykr.
Twórcy
autor
  • Institute of Geotechnics, Slovak Academy of Sciences, Watsonova 45, 04001, Košice, Slovakia
autor
  • Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letná 9, 04200,Košice, Slovakia
autor
  • Institute of Geotechnics, Slovak Academy of Sciences, Watsonova 45, 04001, Košice, Slovakia
autor
  • Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letná 9, 04200,Košice, Slovakia
autor
  • Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letná 9, 04200,Košice, Slovakia
autor
  • Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letná 9, 04200,Košice, Slovakia
autor
  • Faculty of Electrical Engineering and Informatics, Technical University of Kosice, Letná 9, 04200,Košice, Slovakia
Bibliografia
  • 1. “Secure, Clean and Efficient Energy - Horizon 2020 - European Commission”, Horizon 2020. [Online]. Available at: http://ec.europa.eu/programmes/horizon2020/en/h2020- section/secure-clean-and efficient-energy. [Cit: 21-okt-2015].
  • 2. European Commission, Ed., Energy roadmap 2050. Luxembourg: Publications Office of the European Union, 2012.
  • 3. European Commission, Ed., Energy infrastructure. Priorities for 2020 and beyond - A Blueprint for an integrated European energy network. Luxembourg: Publications Office of the European Union, 2011.
  • 4. M. Amin, S. Amin, and M. Ali, “Monitoring of leakage current for composite insulators and electrical devices,” Review on Advanced Materials Science, vol. 21, no. 1, pp. 75–89, 2017.
  • 5. IEC 60071-2: 1996, Insulation co-ordination – Part 2: Application guide. International standard.
  • 6. EC 507: 1991, Artificial pollution tests on high-voltage insulators to be used on a.c. systems. International standard.
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-f0c24ea0-9069-4b39-a392-123a2a85602f
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.