PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The effect of point emitter geometric parameters on dustfall

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Wpływ parametrów geometrycznych emitora punktowego na opad pyłu
Języki publikacji
EN
Abstrakty
EN
In this paper, the modeling results are presented of point emitter geometric parameters determining the dispersion of dust pollution in the atmospheric air and finally also dustfall. The parameters include: the height and diameter of the emitter. Using the maps generated by “Ek100w” programme of Atmoterm company from Opole, Poland, an analysis of the PM10 dustfall value distribution on the analyzed area has been made. Fraction of dust - PM10 - was emitted from emitters of various working parameters. Three situations were analyzed: emission from a one-family (detached) building, from and industrial plant and from a power plant. Different heights and diameters for the above cases were analyzed. What results from the work, is that the mentioned parameters have a significant influence on the value of dustfall on the area surface at different distances from the emitter. With the increase of the height and diameter of the emitter, the values of dustfall decrease. The distance of the maximal values occurrence also increases. Results of similar analysis and available tools allow to design emission in practice, and thus allow a maximal limitation of ambient concentration of pollution and dustfall in areas especially exposed to industrial and superficial emission.
PL
W artykule zaprezentowano wyniki modelowania parametrów geometrycznych emitora punktowego determinujących rozprzestrzenianie się zanieczyszczeń w powietrzu atmosferycznym, a w konsekwencji również opad pyłu. Do parametrów tych należą: wysokość i średnica emitora. Korzystając z map wygenerowanych przez program Ek100w firmy Atmoterm z Opola, przeprowadzono analizę rozkładu wartości opadu pyłu PM10 na analizowanym obszarze. Frakcja PM10 emitowana była z emitorów o różnych parametrach roboczych. Analizowano 3 sytuacje: emisję z gospodarstwa jednorodzinnego, z zakładu przemysłowego oraz z elektrociepłowni. Dla tych przypadków rozpatrywano różne wysokości i średnice emitora. Z artykułu wynika, że wymienione parametry mają znaczny wpływ na ilość pyłu osadzającego się na powierzchni gruntu w różnych odległościach od emitora. Wyniki podobnych analiz oraz dostępne narzędzia pozwalają na projektowanie emisji w praktyce, a tym samym maksymalne ograniczanie imisji oraz opadu zanieczyszczeń na terenach szczególnie narażonych na emisję przemysłową oraz niską emisję.
Rocznik
Strony
83--95
Opis fizyczny
Bibliogr. 7 poz., rys., tab.
Twórcy
  • Institute of Engineering and Environmental Protection, Faculty of Materials, Civil and Environmental Engineering, University of Bielsko-Biala, ul. Willowa 2, 43-300 Bielsko-Biała, Poland, phone +48 33 827 91 38
Bibliografia
  • [1] Technical Guidance Note (Monitoring) M17, Monitoring Particulate Matter in Ambient Air around Waste Facilities. Environment Agency: Version 2; July 2013. https://www.gov.uk/government/uploads/system/uploads/attachment_data/file/301206/TGN_M17_Monitoring_of_particulate_matter_in_ambient_air_around_waste_facilities.pdf
  • [2] Naddafi K, Nabizadeh R, Soltanianzadeh Z, Ehrampoosh MH. Evaluation of dustfall in the air of Yazd. Iran J Environ Health Sci Eng. 2006;3(3):161-168. http://www.bioline.org.br/pdf?se06023
  • [3] Herrick RA. Recommended standard method for continuing dust fall survey (APM-1, Revision 1). J Air Pollut Control Assoc. 2012;16(7):372-377. DOI: 10.1080/00022470.1966.10468490.
  • [4] Esmen NA. A direct measurement method for dustfall. J Air Pollut Control Assoc. 2012;23(1):34-36. DOI: 10.1080/00022470.1973.10469745.
  • [5] DzU 2001, Nr 62, poz. 627, Ustawa z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. (Act of 27th April 2001, Environmental Protection Law, J Laws No. 62, item 627). http://isap.sejm.gov.pl/DetailsServlet?id=WDU20010620627.
  • [6] Janka RM. Zanieczyszczenia pyłowe i gazowe, Podstawy obliczania i sterowania poziomem emisji. (Dust and gas pollution, rudiments of calculation and controlling the level of emissions). Warszawa: Wyd Nauk PWN; 2014.
  • [7] DzU 2010, Nr 16, poz. 87, Rozporządzenie Ministra Środowiska z dnia 26 stycznia 2010 r. w sprawie wartości odniesienia dla niektórych substancji w powietrzu. (Order of the Minister of Environment of 26 January 2010 concerning the reference values for particular substances in the air). http://isap.sejm.gov.pl/DetailsServlet?id=WDU20100160087.
Uwagi
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-f0b84ce0-bce6-4ea7-8a70-644e5a52c48f
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.