PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Energy audit of refrigerated shelving

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This article describes how an energy audit of equipment and the resulting design changes can have a major impact on reducing the electricity consumption of refrigeration equipment. The legal basis introduced by legislation forcing work on the improvement of refrigeration unit is provided. Eight points detail and describe the changes applied to the construction of cooling units. Additionally, a list of the refrigerants which are used is presented, along with the essential parameters of their work. The following analysis includes a description of the research performed along with the measured and calculated results for individual optimisations. The basic parameters that were used for comparison are: daily electricity consumption [kWh/24 h] and the temperature of the packages placed in the device [°C]. Finally, the percentage differences in energy consumption for each modernisation are summarised in a tabular form. The device used for the tests was the VARNA refrigerated rack, model 900, manufactured by P.P.H.U. JUKA Sp. z o.o. sp. k.
Rocznik
Strony
art. no. e2022005
Opis fizyczny
Bibliogr. 10 poz., wykr., wz., tab., rys.
Twórcy
  • Faculty of Mechanical Engineering, Cracow University of Technology
  • Faculty of Mechanical Engineering, Cracow University of Technology
  • Faculty of Mechanical Engineering, Cracow University of Technology
autor
  • Faculty of Mechanical Engineering, Cracow University of Technology
Bibliografia
  • 1. Almogbel, A., Alkasmoul, F., Aldawsari, Z., Alsulami, J., Alsuwailem, A. (2020). Comparison of energy consumption between non-inverter and inverter-type air conditioner in Saudi Arabia. Energy Transitions, 4, 191–197. https://doi.org/10.1007/s41825-020-00033-y
  • 2. Chaomuang, N., Flick, D., Denis, A., Laguerre, O. (2017). Experimental and numerical investigation of the performance of retail refrigerated display cabinets. Trends in Food Science & Technology, 70, 95–104. https://doi.org/10.1016/j.tifs.2017.10.007
  • 3. Chaomuang, N., Flick, D., Denis, A., Laguerre, O. (2019). Influence of operating conditions on the temperature performance of a closed refrigerated display cabinet. International Journal of Refrigeration, 103, 32–41. https://doi.org/10.1016/j.ijrefrig.2019.03.031
  • 4. Heredia-Aricapaa, Y., Belman-Floresa, J.M., Mota-Babiloni, A., Serrano-Arellano, J., García-Pabón, J.J. (2020). Overview of low GWP mixtures for the replacement of HFC refrigerants: R134a, R404A and R410A. International Journal of Refrigeration, 111, 113–123. https://doi.org/10.1016/j.ijrefrig.2019.11.012
  • 5. Onuma, H., Shigeru, M., Toshi, H.A. (2020). How much household electricity consumption is actually saved by replacement with Light-Emitting Diodes (LEDs)? Economic Analysis & Policy, 68, 224–238. https://doi.org/10.1016/j.eap.2020.09.015
  • 6. PN-EN ISO 23953-2:2016-04. Refrigerated display cabinets – Part 2: Classification, requirements and test conditions.
  • 7. Regulation (EU) No 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and repealing Regulation (EC) No 842/2006.
  • 8. Rhiemeir, J.-M., Harnisch, J., Ters, C., Kauffeld, M., Leisewitz, A. (2009). Comparative Assessment of the Climate Relevance of Supermarket Refrigeration Systems and Equipment, Environmental Research of the Federal Ministry of the Environment. In Nature Conservation and Nuclear Safety Research Report 20644300 UBA-FB 001180/e. Germany.
  • 9. Skrzypulec, W., Konopka-Cupiał, G. (2008). Efektywne wykorzystanie energii i czyste środowisko – główne kierunki rozwoju w branży chłodniczej i klimatyzacyjno-wentylacyjnej. Polityka Energetyczna, 11(2), 97–106.
  • 10. Valve Shaban, N.A., Nasser, I., Asfar, J.A., Al-Qawabah, S., Olimat, A.N. (2020). Thermodynamic and Economic Analysis of a Refrigerator Display Cabinet Equipped with a DC Compressor and Electronic Expansion. International Journal of Heat and Technology, 38(2), 432–438. http://doi.org/10.18280/ijht.380219
Uwagi
Section "Mechanics"
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-eefc123c-1c4f-4807-8f5f-c004d3baa92d
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.