Metrological aspects of international intercomparison of passive radon detectors under field conditions in Marie Curie’s tunnel in Lurisia

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
International Conference „Radon in the Environment” (2nd ; 25-29.05.2015 ; Kraków, Poland)
Języki publikacji
EN
Abstrakty
EN
In 2014, an intercomparison exercise of passive radon detectors under field conditions in the Marie Curie’s tunnel belonging to the Lurisia spas complex (Lurisia, Piedmont, Italy) has been held. Radon activity concentration in the tunnel was measured with six radon active monitors, previously calibrated at ENEA-INMRI facilities. In the present paper, a synthesis of the metrological aspects of the intercomparison is given. Indeed particular attention was paid to metrological characterization of radon monitors and their response upon ambient conditions. Correction factors have been defined to be applied when measurements are performed in severe environmental conditions. In particular, it has been found that monitors are particularly sensitive to the effect of air density: the AlphaGUARD (AG-SAPHYMO, GmbH) effi ciency decreases with the air density, while for the MR1 PLUS (Tesys, Italy), the opposite applies. When the reference monitors were placed into the Marie Curie’s tunnel, to the recorded average radon concentrations correction factors were applied. After the correction the difference between data coming from AG and MR1 PLUS is within the 1.7%.
Słowa kluczowe
Czasopismo
Rocznik
Strony
257--261
Opis fizyczny
Bibliogr. 2 poz., rys.
Twórcy
  • ENEA-INMRI, Rome, Italy
autor
  • Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
autor
  • Politecnico di Milano, Milano, Italy
autor
  • Federal Authority for Nuclear Regulation (FANR), United Arab Emirates
autor
  • Italian National Workers Compensation Authority (INAIL), Department of Medicine, Epidemiology, Occupational and Environmental Hygiene, Via Fontana Candida 1, 00040 Monteporzio Catone (Rome) Italy, Tel.: + 39 06 94181 265
autor
  • Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
autor
  • Joint Research Centre (JRC), Ispra, Italy
  • Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
autor
  • Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
autor
  • Italian National Workers Compensation Authority (INAIL), Department of Medicine, Epidemiology, Occupational and Environmental Hygiene, Via Fontana Candida 1, 00040 Monteporzio Catone (Rome) Italy, Tel.: + 39 06 94181 265
autor
  • Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
autor
  • Italian National Workers Compensation Authority (INAIL), Department of Medicine, Epidemiology, Occupational and Environmental Hygiene, Via Fontana Candida 1, 00040 Monteporzio Catone (Rome) Italy, Tel.: + 39 06 94181 265
Bibliografia
  • 1. De Felice, P., & Myteberi, X. (1996). The 222Rn reference measurement system developed at ENEA. Nucl. Instrum. Methods Phys. Res. Sect. A-Accel. Spectrom. Dect. Assoc. Equip., 369(2/3), 445–451.
  • 2. Picolo, J. L. (1996). Absolute measurement of radon 222 activity. Nucl. Instrum. Methods Phys. Res. Sect. A-Accel. Spectrom. Dect. Assoc. Equip., 369(2/3), 452–457.
Uwagi
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-ed3f1014-c267-4fd1-b980-c0eba7e0f467
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.