PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Kinematic Design of the Manipulator for the Upper Limb Rehabilitation

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The article presents the kinematic structure of the manipulator for upper limb rehabilitation. Rehabilitation includes exercises arm, forearm and hand in a range of activities of muscles and joints. The assumptions were prepared on the basis of the analysis of the literature describing the current solutions and suggestions of patients and therapists and the data on the rehabilitation and anthropometry depends on the age and sex. Based on this information as well as having additional interdisciplinary skills, several concepts of kinematic structure of the new rehabilitation device were proposed. This device is the possibility to perform the entire left or right upper limb (arm, forearm and hand) rehabilitation. With this solution it is possible to conduct exercises passively and actively in transverse, sagittal and intermediate surface and biofeedback software.
Rocznik
Strony
107--112
Opis fizyczny
Bibliogr. 8 poz., il.
Twórcy
autor
  • Rzeszów University of Technology. Department of Applied Mechanics and Robotics
Bibliografia
  • 1. Bochenek A., Reicher M. 2009, Human Anatomy Volume I. (original title in Polish: Anatomia człowieka tom I.), Wydaw. Lek. PZWL, Warszawa.
  • 2. Buerger S.P., Krebs H.I., Ferraro M. 2004, Rehabilitation robotics: pilot trial of a spatial extension for MIT-Manus, Journal of NeuroEngineering and Rehabilitation 2004, 1:5.
  • 3. Coote S., Stokes E.K. 2003, The GENTLE/s clinical trial: effect of treatment on maximal voluntary isometric contraction, Proceedings 7th Conference AAATE Dublin.
  • 4. Gedliczka A., Pochopień P., Szklarska A., Welon Z. 2001, Atlas of human measure. Data for the ergonomic design and evaluation (original title in Polish: Atlas miar człowieka. Dane do projektowania i oceny ergonomicznej), Centralny Instytut Ochrony Pracy, Warsaw.
  • 5. Pąchalska M. 2007, Clinical Neuropsychology Volume II (original title in Polish: Neuropsychologia kliniczna tom II), Wydaw. Naukowe PWN.
  • 6. Tutak J. 2012, Manipulator for Upper limb rehabilitation, (original title in Polish: Manianipulator do rehabilitacji kończyny górnej), PhD Thesis.
  • 7. Winkler T. 2005, Computer aided design systems anthropotechnical (original title in Polish: Komputerowo wspomagane projektowanie systemów antropotechnicznych), Wydaw. Naukowo-Techniczne, Warsaw.
  • 8. Wolański N., Niemiec S., Pyżuk M. 1975, Engineering anthropometry (original title in Polish: Antropometria inżynieryjna), Wydaw. Książka i Wiedza, Warsaw.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-ec4b0caa-f111-44bd-858e-e024949d646f
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.