PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
Tytuł artykułu

Production of laser-polarized 3He gas via metastability exchange optical pumping for magnetic resonance imaging

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The state-of-the-art in the production of hyperpolarized 3He gas for magnetic resonance imaging (MRI) of the human lungs is reviewed. The paper is focused on the metastability exchange optical pumping (MEOP) method, which is preferable in medical applications, because the polarized 3He gas is free of any contaminants. Two strategies, namely, “centralized” and “onsite” production, are compared from the point of view of efficiency, level of achievable polarization, and the cost. A novel design of the polarizer that is based on MEOP operating in nonstandard conditions is also presented. It is the most promising solution for the implementation of the technique in medical clinics, as it uses the magnetic field of the MRI scanner and operates at elevated 3He gas pressure.
Rocznik
Strony
129--137
Opis fizyczny
Bibliogr. 62 poz., rys.
Twórcy
autor
  • Institute of Physics, Jagiellonian University, Kraków 30-059, Poland
autor
  • Department of Chemistry and Physics, Agricultural University, Kraków, Poland
  • Institute of Physics, Jagiellonian University, Kraków, Poland; and Institute of Nuclear Physics, Polish Academy of Sciences, Kraków, Poland
Bibliografia
  • 1. Bhaskar ND, Happer W, McClelland T. Efficiency of spin exchange between rubidium spins and 129Xe nuclei in a gas. Phys Rev Lett 1982;49:25–8.
  • 2. Colegrove FD, Schearer LD, Walters GK. Polarization of He3 gas by optical pumping. Phys Rev 1963;132:2561–72.
  • 3. Flowers JL, Petley BW, Richards MG. A measurement of the nuclear magnetic moment of the helium-3 atom in terms of that of the proton. Metrologia 1993;30:75.
  • 4. Bauman G, Puderbach M, Heimann T, Kopp-Schneider A, Fritzsching E, Mall MA, et al. Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients. Eur J Radiol 2013;82:2371–7.
  • 5. Albert MS, Cates GD, Driehuys B, Happer W. Biological magnetic resonance imaging using laser-polarized 129Xe. Nature 1994;370:199–201.
  • 6. Middleton H, Black RD, Saam B, Cates GD, Cofer GP, Guenther R, et al. MR imaging with hyperpolarized 3He gas. Magn Reson Med 1995;33:271–75.
  • 7. Bidinosti CP, Choukeife J, Tastevin G, Nacher PJ, Vignaud A. MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT). Magn Reson Mater Phys Biol Med 2004;16:255–8.
  • 8. Darrasse L, Guillot G, Nacher PJ, Tastevin G. Low-field 3He nuclear magnetic resonance in human lungs. Comptes Rendus Acad Sci Ser IIB Mech-Phys-Chem-Astron 1997;324:691–700.
  • 9. Bachert P, Schad LR, Bock M, Knopp MV, Ebert M, Großmann T, et al. Nuclear magnetic resonance imaging of airways in humans with use of hyperpolarized 3He. Magn Reson Med 1996;36:192–6.
  • 10. Ebert M, Grossmann T, Heil W, Otten EW. Nuclear magnetic resonance imaging with hyperpolarised helium-3. Lancet 1996;347:1297–9.
  • 11. Kauczor HU, Hofmann D, Kreitner KF, Nilgens H, Surkau R, Heil W, et al. Normal and abnormal pulmonary ventilation: visualization at hyperpolarized He-3 MR imaging. Radiology 1996;201:564–8.
  • 12. Saam BT, Yablonskiy DA, Kodibagkar VD, Leawoods JC, Gierada DS, Cooper JD, et al. MR imaging of diffusion of 3He gas in healthy and diseased lungs. Magn Reson Med 2000;44:174–9.
  • 13. Wild JM, Fichele S, Woodhouse N, Paley MN, Kasuboski L, van Beek EJ. 3D volume-localized pO2 measurement in the human lung with 3He MRI. Magn Reson Med 2005;53:1055–64.
  • 14. Bouchiat MA, Carver TR, Varnum CM. Nuclear polarization in He3 gas induced by optical pumping and dipolar exchange. Phys Rev Lett 1960;5:373–5.
  • 15. Happer W, Miron E, Schaefer S, Schreiber D, van Wijngaarden WA, Zeng X. Polarization of the nuclear spins of noble-gas atoms by spin exchange with optically pumped alkali-metal atoms. Phys Rev A 1984;29:3092–110.
  • 16. Nacher PJ, Leduc M. Optical pumping in 3He with a laser. J Phys France 1985;46:2057–73.
  • 17. Larat C. Chapter II: Efficacité du Pompage Optique par laser dans l’hélium-3 pur et dans les mélanges hélium-3/hélium-4. PhD thesis, L’Universite Paris 6, France, 1991.
  • 18. Collier G, Palasz T, Wojna A, Glowacz B, Suchanek M, Olejniczak Z, et al. A high-field 3He metastability exchange optical pumping polarizer operating in a 1.5 T medical scanner for lung magnetic resonance imaging. J Appl Phys 2013;113:204905.
  • 19. Nacher PJ. Magnetic resonance imaging: from spin physics to medical diagnosis. In: Duplantier B, Raimond JM, Rivasseau V, editors. The Spin, volume 55 of Prog Math Phys. Birkhauser, Basel, 2009:159–93.s.
  • 20. Tastevin G, Grot S, Courtade E, Bordais S, Nacher PJ. A broadband ytterbium-doped tunable fiber laser for 3He optical pumping at 1083 nm. Appl Phys B Lasers Opt 2004;78:145–56.
  • 21. Batz M, Nacher PJ, Tastevin G. Fundamentals of metastability exchange optical pumping in helium. J Phys Conf Ser 2011;294:012002.
  • 22. Bannier E, Cieslar K, Mosbah K, Aubert F, Duboeuf F, Salhi Z, et al. Hyperpolarized 3He MR for sensitive imaging of ventilation function and treatment efficiency in young cystic fibrosis patients with normal lung function. Radiology 2010;255:225–32.
  • 23. Gast KK, Dahmen A, Heussel C, Biedermann A, Schmiederkamp J, Wild JM, et al. 3He-MRI in a European multicenter trial in COPD and emphysema “PHIL”. Poster session presented at the Proc Intl Soc Magn Reson Med, 2004.
  • 24. Gast KK, Hawig KM, Windirsch M, Markstaller K, Schreiber WG, Schmiedeskamp J, et al. Intrapulmonary 3He gas distribution depending on bolus size and temporal bolus placement. Invest Radiol 2008;43:439–46.
  • 25. Mosbah K, Stupar V, Berthezene Y, Beckmann N, Cremillieux Y. Spatially resolved assessment of serotonin-induced bronchoconstrictive responses in the rat lung using 3He ventilation MRI under spontaneous breathing conditions. Magn Reson Med 2010;63:1669–74.
  • 26. Terekhov M, Rivoire J, Scholz A, Wolf U, Karpuk S, Salhi Z, et al. Measurement of gas transport kinetics in high-frequency oscillatory ventilation (HFOV) of the lung using hyperpolarized 3He magnetic resonance imaging. J Magn Reson Imaging 2010;32:887–94.
  • 27. Wild JM, Paley MN, Kasuboski L, Swift A, Fichele S, Woodhouse N, et al. Dynamic radial projection MRI of inhaled hyperpolarized 3He gas. Magn Reson Med 2003;49:991–7.
  • 28. Beek EJ, Schmiedeskamp J, Wild JM, Paley MN, Filbir F, Fichele S, et al. Hyperpolarized 3-helium MR imaging of the lungs: testing the concept of a central production facility. Eur Radiol 2003;13:2583–6.
  • 29. Choukeife J, Maitre X, Tastevin G, Nacher PJ. On-site production of hyperpolarized helium-3 gas for lung MRI. Proceedings of the 11th ISMRM Scientific Meeting & Exhibition, July 10–16, 2003:1391.
  • 30. Suchanek K, Cieslar K, Olejniczak Z, Palasz T, Dohnalik T, Suchanek M. Hyperpolarized 3He gas production by metastability exchange optical pumping for magnetic resonance imaging. Opt Appl 2005;35:263–76.
  • 31. Gentile TR, Rich DR, Thompson AK. Compressing spin-polarized 3He with a modified diaphragm pump. J Res Natl Inst Stand Technol 2001;106:709–29.
  • 32. Becker J, Heil W, Krug B, Leduc M, Meyerhoff M, Nacher PJ, et al. Study of mechanical compression of spin-polarized 3He gas. Nucl Instrum Methods Phys Res Sect A Accel Spectrom Detect Assoc Equip 1994;346:45–51.
  • 33. Eckert G, Heil W, Meyerhoff M, Otten EW, Surkau R, Werner M, et al. A dense polarized 3He target based on compression of optically pumped gas. Nucl Instrum Methods Phys Res Sect A Accel Spectrom Detect Assoc Equip 1992;320:53–65.
  • 34. Schmiedeskamp J, Elmers HJ, Heil W, Otten EW, Sobolev Y, Kilian W, et al. Relaxation of spin polarized 3He by magnetized ferromagnetic contaminants. Eur Phys J D Atomic Mol Opt Plasma Phys 2006;38:445–54.
  • 35. Schmiedeskamp J, Heil W, Otten EW, Kremer RK, Simon A, Zimmer J. Paramagnetic relaxation of spin polarized 3He at bare glass surfaces. Eur Phys J D Atomic Mol Opt Plasma Phys 2006;38:427–38.
  • 36. Mrozik C, Endner O, Hauke C, Heil W, Karpuk S, Klemmer J, et al. Construction of a compact 3He polarizing facility. J Phys Conf Ser 2011;294:012007.
  • 37. Wild JM, Schmiedeskamp J, Paley MN, Filbir F, Fichele S, Kasuboski L, et al. MR imaging of the lungs with hyperpolarized helium-3 gas transported by air. Phys Med Biol 2002;47:N185.
  • 38. Batz M, Baeßler S, Heil W, Otten EW, Rudersdorf D, Schmiedeskamp J, et al. 3He spin filter for neutrons. J Res Natl Inst Stand Technol 2005;110:293–8.
  • 39. Karpuk S, Allmendinger F, Burghoff M, Gemmel C, Guldner M, Heil W, et al. Spin polarized 3He: from basic research to medical applications. Phys Particles Nuclei 2013;44:904–8.
  • 40. Hiebel S, Großmann T, Kiselev D, Schmiedeskamp J, Gusev Y, Heil W, et al. Magnetized boxes for housing polarized spins in homogeneous fields. J Magn Reson 2010;204:37–49.
  • 41. Thien F, Friese M, Cwin G, Maillet D, Wang D, Galloway G, et al. Feasibility of functional magnetic resonance lung imaging in Australia with long distance transport of hyperpolarized helium from Germany. Respirology 2008;13:599–602.
  • 42. Stoltz E, Meyerhoff M, Bigelow N, Leduc M, Nacher PJ, Tastevin G. High nuclear polarization in 3He and 3He–4He gas mixtures by optical pumping with a laser diode. Appl Phys B 1996;63:629–33.
  • 43. Talbot C, Batz M, Nacher PJ, Tastevin G. An accurate optical technique for measuring the nuclear polarisation of 3He gas. J Phys Conf Ser 2011;294:012008.
  • 44. Nacher PJ, Tastevin G, Maitre X, Dollat X, Lemaire B, Olejnik B. A peristaltic compressor for hyperpolarized helium. Eur Radiol 1999;9:B18.
  • 45. Nacher PJ. Peristaltic compressors suitable for relaxation-free compression of polarized gas. United States Patent n°US6655931, 2003.
  • 46. Durand E, Guillot G, Darrasse L, Tastevin G, Nacher PJ, Vignaud A, et al. CPMG measurements and ultrafast imaging in human lungs with hyperpolarized helium-3 at low field (0.1 T). Magn Reson Med 2002;47:75–81.
  • 47. Vignaud A, Maitre X, Guillot G, Durand E, de Rochefort L, Robert P, et al. Magnetic susceptibility matching at the air–tissue interface in rat lung by using a superparamagnetic intravascular contrast agent: Influence on transverse relaxation time of hyperpolarized helium-3. Magn Reson Med 2005;54:28–33.
  • 48. Collier G, Suchanek M, Wojna A, Cieslar K, Palasz T, Glowacz B, et al. Metastability exchange optical pumping low field polarizer for lung magnetic resonance imaging. Opt Appl 2012;42:223–39.
  • 49. Suchanek M, Cieslar K, Palasz T, Suchanek K, Dohnalik T, Olejniczak Z. Magnetic Resonance Imaging at Low Magnetic Field Using Hyperpolarized 3He Gas. Acta Phys Pol A 2005;107:491–506.
  • 50. Hussey DS, Rich DR, Belov AS, Tong X, Yang H, Bailey C, et al. Polarized 3He gas compression system using metastability-exchange optical pumping. Rev Sci Instrum 2005;76:053503.
  • 51. Abboud M, Sinatra A, Maitre X, Tastevin G, Nacher PJ. High nuclear polarization of 3He at low and high pressure by metastability exchange optical pumping at 1.5 tesla. Europhys Lett 2004;68:480–6.
  • 52. Courtade E, Marion F, Nacher PJ, Tastevin G, Dohnalik T, Kiersnowski K. Spectroscopy of the helium 2 3S–2 3P transition above 0.01 Tesla – application to optical pumping studies. Hyperfine Interact 2000;127:451–4.
  • 53. Nikiel A, Palasz T, Suchanek M, Abboud M, Sinatra A, Olejniczak Z, et al. Metastability exchange optical pumping of 3He at high pressure and high magnetic field for medical applications. Eur Phys J Special Top 2007;144:255–63.
  • 54. Courtade E, Marion F, Nacher PJ, Tastevin G, Kiersnowski K, Dohnalik T. Magnetic field effects on the 1083 nm atomic line of helium. Eur Phys J D Atomic Mol Opt Plasma Phys 2002;21:25–55.
  • 55. Nikiel-Osuchowska A, Collier G, Głowacz B, Pałasz T, Olejniczak Z, Węglarz W, et al. Metastability exchange optical pumping of 3He gas up to hundreds of millibars at 4.7 Tesla. Eur Phys J D 2013;67:1–29.
  • 56. Dohnalik T, Nikiel A, Palasz T, Suchanek M, Collier G, Grenczuk M, et al. Optimization of the pumping laser beam spatial profile in the MEOP experiment performed at elevated 3He pressures. Eur Phys J Appl Phys 2011;54:20802.
  • 57. McLeod JH. The axicon: a new type of optical element. J Opt Soc Am 1954;44:592.
  • 58. Güldner M, Becker S, Friesenecker A, Gast KK, Heil W, Karpuk S, et al. Realization of administration unit for 3He with gas recycling. J Phys Conf Ser 2011;294:012006.
  • 59. Shea DA, Morgan D. The helium-3 shortage: supply, demand, and options for congress. Congressional Research Service Report for Congress, 2010.
  • 60. Salhi Z, Grossmann T, Gueldner M, Heil W, Karpuk S, Otten EW, et al. Recycling of 3He from lung magnetic resonance imaging. Magn Reson Med 2012;67:1758–63.
  • 61. Moskal P, Salabura P, Silarski M, Smyrski J, Zdebik J, Zieliński M. Novel detector systems for the positron emission tomography. Bio-Algorithms Med-Syst 2011;7:73.
  • 62. Moskal P. Hybrid tomograph TOF-PET/MRI. Patent Application No. P 405 184, 2013.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-e7d405e5-c5aa-4e37-ace0-9dc3350698f9
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.