Identyfikatory
Warianty tytułu
Konferencja
Computer Applications in Electrical Engineering 2013 (15-16.04.2013; Poznań, Polska)
Języki publikacji
Abstrakty
The paper describes an investigation of fault tolerant control strategies for permanent magnet synchronous motor (PMSM) driven by a fault-tolerant inverter. The inverter is a topology-modified inverter with fault-tolerant capability, which can be configured as the standard 3-phase 6-switch inverter and reconfigured as 3-phase 4-switch or 2-phase 4-switch inverter under the fault condition. By analyzing operating principle of a fault-tolerant inverter and the mathematical model of PMSM, fault tolerant control algorithms are investigated. There is a conclusion that three phase stator windings of PMSM can be effectively operated by controlling only two phase currents. Simulation results show the validity of the proposed methods.
Słowa kluczowe
Rocznik
Tom
Strony
165--172
Opis fizyczny
Bibliogr. 4 poz., rys., tab.
Twórcy
autor
- Poznan University of Technology
Bibliografia
- [1] Welchko, B.A., Lipo, T.A., Jahns, T.M., Schulz, S.E., Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations, IEEE Transactions on Power Electronics vol. 19 , iss.4, p. 1108 - 1116, 2004.
- [2] Doc, C., Lanfranchi, V., Friedrich, G., Inverter topology comparison for remedial solution in transistor faulty case, in Proc. Eur. Power Electron. Appl., p. 1-8, 2007.
- [3] Sun, D., Meng, J., Research on fault tolerant inverter based permanent magnet synchronous motor direct torque control drives, in Proc. IEEE Int. Conf. Ind. Electron. Appl., Singapore, p. 1-5, 2006.
- [4] Bolognani, S., Zordan, M., Zigliotto, M., Experimental fault-tolerant control of PMSM drive. IEEE Tran. Ind. Electron., vol. 47, p. 1134-1141, 2000.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-e6b67b19-7ce3-4342-b3f6-05baea87a996