Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
The new method is proposed in the paper for determination of volume porosity of bone tissue based on histograms of 3D mCT scans and also precise defi nition of the threshold value of relative density preserving calculated volume porosity during the reconstruction of the binary image of sample. In this method the normed histogram is considered as a probability distribution of relative mass density in the bone sample. It was shown that the normed histograms of increasing 3D sample are convergent to the limit curve which can be interpreted as a representative histogram of given sample. The limit histograms have been used to determine: the distributions of relative densities in the sets of voxels of pore and skeleton type and their characteristics, the volume porosities of both samples and thresholds values of their binarisation.
Wydawca
Czasopismo
Rocznik
Tom
Strony
88--89
Opis fizyczny
wykr., rys., tab.
Twórcy
autor
- Institute of Mechanics and Applied Computer Science, Kazimierz Wielki University, Chodkiewicza 30, 85-064 Bydgoszcz
autor
autor
Bibliografia
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-e4598014-a2a9-45d4-8f07-a3df51a2a757