PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Design and implementation of a vein detection system for improved accuracy in blood sampling

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Projektowanie i wdrożenie systemu detekcji żył w celu zwiększenia dokładności pobierania krwi
Języki publikacji
EN
Abstrakty
EN
Blood sampling is a routine procedure in medical diagnostics, yet precise vein visualization methods remain limited. This projectintroducesa system designed to improve vein detection during blood collection. It relies on Near-Infrared (NIR) light, which interacts with the skin and highlights veins by taking advantage of hemoglobin’s infrared absorption properties. Using a Raspberry Pi and an infrared camera, image acquisitionand processing are handled through MATLAB and Python algorithms, which allow real-time visualization of veins. The system has been testedon a database of infrared images of hands and arms, effectively enhancing vein contrast in real time. The display is connected to the Raspberry Pi, giving medical staff a visual guide. This technology aims to streamline procedures for healthcare professionals, including doctors, nurses, and medical students, particularly in high-volume settings like labs and blood transfusion centers where vein visualization is critical to patient care.
PL
Pobieranie krwi jest rutynową procedurą w diagnostyce medycznej, jednak precyzyjne metody wizualizacji żył pozostają ograniczone. Projekt ten wprowadza system mający na celu usprawnienie wykrywania żył podczas pobierania krwi. Opiera się na świetle bliskiej podczerwieni (NIR),które oddziałuje ze skórą i uwydatnia żyły, wykorzystując właściwości absorpcji podczerwieni przez hemoglobinę. Przy użyciu Raspberry Pi i kameryna podczerwień akwizycja i przetwarzanie obrazu odbywa się za pomocą algorytmów MATLAB i Python, które umożliwiają wizualizację żył w czasie rzeczywistym. System został przetestowany na bazie danych obrazów dłoni i ramion w podczerwieni, skutecznie zwiększając kontrast żył w czasie rzeczywistym. Wyświetlacz jest podłączony do Raspberry Pi, zapewniając personelowi medycznemu wizualne wskazówki. Technologiata ma na celu usprawnienie procedurstosowanych przez pracowników służby zdrowia, w tym lekarzy, pielęgniarki i studentów medycyny, szczególnie w środowiskacho dużym natężeniu ruchu, takich jak laboratoria i centra transfuzji krwi, gdzie wizualizacja żył ma kluczowe znaczenie dla opieki nad pacjentem.
Rocznik
Strony
131--134
Opis fizyczny
Bibliogr. 14 poz., fot., wykr.
Twórcy
  • Mohammed V University in Rabat, Electronic Systems, Sensors and Nanobiotechnologies (E2SN), High National School of Arts and Crafts (ENSAM), Rabat, Morocco
autor
  • Mohammed V University in Rabat, Electronic Systems, Sensors and Nanobiotechnologies (E2SN), High National School of Arts and Crafts (ENSAM), Rabat, Morocco
  • Higher Institute of Maritime Studies (ISEM), Casablanca, Morocco
Bibliografia
  • [1] Aboshosha A. et al.: Image denoising based on spatial filters, an analytical study. International Conference on Computer Engineering & Systems. IEEE, 2009, 245–250.
  • [2] Almajidy R. K. et al.: A newcomer's guide to functional near infrared spectroscopy experiments. IEEE Reviews in Biomedical Engineering 13, 2019, 292–308.
  • [3] Amritha P. P., Induja K., Rajeev K.: Active warden attack on steganography using Prewitt filter. International Conference on Soft Computing Systems. Springer, New Delhi 2016, 591–599.
  • [4] Aqrawi A. A., Boe T. H.: Improved fault segmentation using a dip guided and modified 3D Sobel filter. Society of Exploration Geophysicists Technical Program Expanded Abstracts 2011, 999–1003.
  • [5] Brownrigg D. R.: The weighted median filter. Communications of the ACM 27(8), 1984, 807–818.
  • [6] Di Franco M. et al.: Diastolic function abnormalities in rheumatoid arthritis. Evaluation by echo Doppler transmitral flow and pulmonary venous flow: relation with duration of disease. Annals of the Rheumatic Diseases 59(3), 2000, 227–229.
  • [7] Dumoulin C. L., Hart Jr. H. R.: Magnetic resonance angiography. Radiology 161(3), 1986, 717–720.
  • [8] Gomes D. M.: Contrast enhancement in digital imaging using histogram equalization. Doctoral dissertation. Université Paris-Est, 2014.
  • [9] Gómez E. et al.: Diagnosis of thoracic outlet syndrome by angio-MRI. Radiologia 48(5), 2006, 295–300.
  • [10] Kong H., Akakin H. C., Sarma S. E.: A generalized Laplacian of Gaussian filter for blob detection and its applications. IEEE Transactions on Cybernetics 43(6), 2013, 1719–1733.
  • [11] Okhnyanskaya L. G. et al.: Assessment of the human regional cerebral blood flow by venous occlusion rheoplethysmoencephalography. Bulletin of Experimental Biology and Medicine 82(5), 1976, 1755–1758.
  • [12] Thomas M. L.: Phlebography. Archives of Surgery 104(2), 1972, 145–151.
  • [13] Upton E., Halfacree G.: Raspberry Pi User Guide. John Wiley & Sons, 2014.
  • [14] Zeman R. K. et al.: CT angiography. AJR. American Journal of Roentgenology 165(5), 1995, 1079–1088.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-e2164b71-eca8-4379-a1d2-294c295da527
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.