Tytuł artykułu
Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Zastosowanie woltamperometrii anodowej do oznaczania antymonu w glebach
Języki publikacji
Abstrakty
Conditions of determination of antimony(V) using anodic stripping voltammetry with differential pulse technique and hanging mercury drop electrode have been analyzed. Antimony was extracted from soils with HCl+HNO3 mixture (3:1). Deposition time was 15÷30 s, deposition potential –0.5 V and supporting electrolyte 3 M HCl. In the above conditions Sb(V) peak height vs its concentration dependence is linear up to 7·10–5 M antimony. The accuracy and precision of the proposed method is also satisfactory. The relative standard deviation for 1.5·10–7 M Sb(V) equals 7.5% and for 4·10–7 M Sb(V) equals 14.3%). The method has been applied to study the degree of contamination of soils in the vicinity of Huta Głogów copper smelter with antimony.
W pracy opracowano metodykę oznaczania Sb(V) w ekstraktach glebowych, wykorzystując w tym celu woltamperometrię anodową. Antymon z gleb ekstrahowano mieszaniną HCl+HNO3 (3:1). Pomiarów dokonano w technice różnicowej pulsowej, stosując wiszącą rtęciową kroplową elektrodę. Elektrolitem podstawowym był 3 mol·dm -3 HCl. Czas zatężania wynosił 15÷30 s, potencjał zatężania –0,5 V wzgl. NEK. W tych warunkach krzywa kalibracji ma przebieg prostoliniowy aż do 7·10–5 mol·dm–3 Sb(V). Dokładność i precyzja opracowanej metodyki są zadowalające (względne odchylenie standardowe dla 1,5·10–7 mol·dm–3 Sb(V) wynosi 7,5%, dla 4.0·10–7 mol·dm–3 Sb(V) 14,3%). Opracowaną metodykę wykorzystano do oceny stopnia zanieczyszczenia antymonem terenów usytuowanych w zagłębiu miedziowym w pobliżu Huty Głogów.
Czasopismo
Rocznik
Tom
Strony
369--372
Opis fizyczny
Bibliogr. 18 poz., rys., tab.
Twórcy
autor
- Institute of Chemistry, Poznan University of Technology, ul. Piotrowo 3, 60-965 Poznań
Bibliografia
- [1] Kabata-Pendias A. and Pendias H.: Biogeochemia pierwiastków śladowych. WN PWN, Warszawa 1995.
- [2] Capodaglio G., Van den Berg C.M.G. and Scarponi G.: J. Electroanal. Chem., 1987, 235, 275-286.
- [3] Zhang X., Ma C., Wang L. and Zhang J.: Talanta, 1995, 42, 897-900.
- [4] Wagner W., Sander S. and Henze G.: Fresenius Z. Anal. Chem., 1996, 354, 11-15.
- [5] Zhou C., Lu Y., Li X., Luo C. and Zhang Z.: Talanta, 1998, 46, 1531-1536.
- [6] Bond A.M., Kratsis S. and Newman O.M.G.: Anal. Chim. Acta, 1998, 372, 307-314.
- [7] Hofbauerova H., Labuda J., Fisera M. and Vanickova M.: Electroanalysis, 1995, 7, 788-790.
- [8] Waller P.A. and Pickering W.F.: Talanta, 1995, 42, 197-204.
- [9] Brodersen K., Hassan H.N.A., Hassouna M.E.M. and Habib I.H.I.: Fresenius Z. Anal. Chem., 1997, 358, 745-748.
- [10] Bond A.M., Kratsis S., Newman O.M.G. and Pfund B.V.: Electroanalysis, 1997, 9, 13-18.
- [11] Locatelli C.: Electroanalysis, 1997, 9, 560-563.
- [12] Bond A.M., Kratsis S. and Newman O.M.G.: Electroanalysis, 1997, 9, 681-684.
- [13] Postupolski A. and Golimowski J.: Electroanalysis, 1991, 3, 793-797.
- [14] Quentel F. and Filella M.: Anal. Chim. Acta, 2002, 452, 237-244.
- [15] Ghoneim M.M., Hassanein A.M. and Hammam E.: Fresenius Z. Anal. Chem., 2000, 367, 378-383.
- [16] Locatelli C.: J. Sci. Food Agric., 2007, 87, 305-312.
- [17] Melucci D., Torsi G. and Locatelli C.: Annali di Chimica, 2007, 97, 141-151.
- [18] Wolf A., Schramel P., Lill G. and Horn H.: Fresenius Z. Anal. Chem., 1984, 317, 512-519.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-deb562da-82c7-4e6d-bc38-1dd92c2df7a0