Tytuł artykułu
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Analiza bezpieczeństwa wybranych zabiegów kosmetycznych
Języki publikacji
Abstrakty
The paper presents the results of electromagnetic field measurements to which both the client and the staff of the equipment in beauty salons are exposed. The examined object was a device for facial beauty treatments using ultrasound. The measurements were made with a Maschek type ESM 100 meter. The maximum value of the electric component E=158 V/m was measured in the environment of the service staff (beautician) and magnetic induction B=628 nT. A statistical analysis was performed in Statistica 13.3 in order to observe the exact differences between the measurement with the device switched off (background) and the device in operation.
W pracy przedstawiono wyniki pomiarów pola elektromagnetycznego na które narażony jest zarówno klient jak i obsługa aparatury w salonach kosmetycznych. Badanym przedmiotem było urządzenie do zabiegów upiększających twarz z wykorzystaniem ultradźwięków. Pomiary wykonano miernikiem firmy Maschek typ ESM 100. Maksymalną wartość składowej elektrycznej E=158 V/m zmierzono w otoczeniu personelu obsługi (kosmetyczki) natomiast wartość indukcji magnetycznej B=628 nT. Wykonano analizę statystyczna w programie Statistica 13.3 w celu zaobserwowania dokładnych różnić miedzy pomiarem przy urządzeniu wyłączonym (tło), a pracującym.
Wydawca
Czasopismo
Rocznik
Tom
Strony
148--151
Opis fizyczny
Bibliogr. 18 poz., rys., tab.
Twórcy
autor
- Politechnika Lubelska, Wydział Elektrotechniki i Informatyki, Katedra Elektrotechniki i Elektrotechnologii, ul. Nadbystrzycka 38 A, 20-618 Lublin
autor
- Państwowa Wyższa Szkoła Zawodowa Chełmie, Instytut Nauk Technicznych i Lotnictwa, ul. Pocztowa 54, 22-100 Chełm
autor
- Politechnika Lubelska, Wydział Elektrotechniki i Informatyki, Katedra Elektrotechniki i Elektrotechnologii, ul. Nadbystrzycka 38 A, 20-618 Lublin
Bibliografia
- [1] Bieńkowski P., Optimization of radiocommunication installations for minimizing exposure the environment to the EMF, 2020, Przegląd Elektrotechniczny, 1(1), 228-231
- [2] Gas P., Modelling the temperature-dependent RF ablation produced by the multi-tine electrode, Przegląd Elektrotechniczny, 2020, vol. 96, no. 1, 48-51
- [3] Gas P., M iaskowski A., Implant Safety Tool Application to Assist the Assessment of Radio-Frequency Radiation Exposure, Journal of Ecological Engineering, 2019, vol. 20, no. 10, 24-33
- [4] Jun S., Kochan O., Chunzhi W., Kochan R., Theoretical and experimental research of error of method of thermocouple with controlled profile of temperature field, Measurement Science Review, 2015, 15(6), 304-312
- [5] Jun S., Kochan O., Common mode noise rejection in measuring channels, Instruments and Experimental Techniques, 2015, 58(1), 86-89
- [6] Liu S., Chai K., Zhang Ch., Jin L., Yang Q., Electromagnetic Acoustic Detection of Steel Plate Defects Based on High-Energy Pulse Excitation, Applied Sciences, 2020, 10 (16), 5534
- [7] Mazurek P., Michałowska J., Kozieł J., Gad R., Wdowiak A., The intensity of electromagnetic fields in the range of GSM 900, GSM 1800 DECT, UMTS, WLAN in built-up areas, Applications of Electromagnetics in Modern Techniques and Medicine (PTZE), 2018, DOI: 10.1109/PTZE.2018.8503156
- [8] Michałowska J., Tofil A., Jóźwik J., Pytka J., Legutko S., Siemiątkowski Z., Łukaszewicz A., Monitoring the risk of the electric component imposed on a pilot during light aircraft operations in a high-frequency electromagnetic field, Sensors (Switzerland), 2019
- [9] Pytka J.,Budzyński P., Łyszczyk T., Józwik J ., Michałowska J., Tofil A., Błażejczak D.,Laskowski J., Determining wheel forces and moments on aircraft landing gear with a dynamometer sensor, Sensors (Switzerland), 2020
- [10] Michałowska J., Tofil A., Jóźwik J., Pytka J., Budzyński P., Korzeniewska E., Measurement of high-frequency electromagnetic fields in CNC machine tools area, Proceedings of the 2018 IEEE 4th International Symposium on Wireless Systems within the International Conferences on Intelligent Data Acquisition and Advanced Computing Systems, IDAACS- SWS, 2018
- [11] Michałowska J., Wac-Włodarczyk A., Kozieł J., Monitoring of the Specific Absorption Rate in Terms of Electromagnetic Hazards, Journal of Ecological Engineering, 2020, 21(1), 224-230
- [12] Mika D., Michałowska J., Measurements of the level of harmful factors in the workplace of numerically operated milling machine, Przegląd Elektrotechniczny, 2016
- [13] Pater Z., Tomczak J., Bulzak T., Bartnicki J., Tofil A. Prediction of crack formation for cross wedge rolling of harrow tooth preform, Materials, 12(14), 2019
- [14] Pater Z., Tofil A., Tomczak J., Steel balls forming by cross rolling with upsetting, Metalurgija (2013) 52(1) 103-106
- [15] Pieniak D., Walczak A., Walczak M., Przystupa K., Niewczas A., Hardness and wear resistance of dental biomedical nanomaterials in a humid environment with nonstationary temperatures, Materials, 2020
- [16] Przystupa K., Pohrebennyk V., Mitryasova O., Kochan O., Assessment of the electromagnetic radiation level of vehicles, computers, household appliances, personal care products, mobile phones and smartphones, Przegląd Elekrotechniczny, 2020
- [17] Przystupa K., Pohrebennyk V., Mitryasova O., Kochan O, The influence of electromagnetic field on human health, 2019 Applications of Electromagnetics in Modern Engineering and Medicine, PTZE 2019
- [18] Rozporządzenia Ministra rodziny, pracy i polityki społecznej z dnia 30 czerwca 2016 poz. 952 w sprawie najwyższych dopuszczalnych stężeń i natężeń czynników szkodliwych dla zdrowia w środowisku pracy.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2021).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-de2942ef-d297-448a-bcd3-e0e5b288b5be