PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Heat transfer and friction characteristics in three-side solar air heaters with the combination of multi-v and transverse wire roughness

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The present paper describes the experimental analysis of heat transfer and friction factor for glass protected three-side artificially roughened rectangular duct solar air heaters (SAHs) having an arrangement of multiple-v and transverse wires (top wall multi-v and two side walls transverse) under the absorber plate, and compares their performance with that of one-side roughened solar air heaters under similar operating conditions. The investigated three-side solar air heaters are characterized by a larger rate of heat transfer and friction factor as compared to one-side artificially roughened SAHs by 24–76% and 4–36%, respectively, for the identical operating parameters. The air temperature below the three-side rugged duct is by 34.6% higher than that of the one-side roughened duct. Three-side solar air heaters are superior as compared to one-side artificially roughened solar air heaters qualitatively and quantitatively both.
Rocznik
Strony
63--87
Opis fizyczny
Bibliogr. 34 poz., rys., tab., wykr.
Twórcy
  • B.A. College of Engineering and Technology, Ghutia, P.O. Barakhurshi Jamshedpur, Jharkhand 832304, India
Bibliografia
  • [1] Bhatti M.S., Shah R.K.: Turbulent and Transition Flow Convective Heat Transfer Handbook of Single Phase Convective Heat Transfer. Wiley, New York 1987.
  • [2] Garg H.P., Prakash J.: Solar Energy Fundamentals and Applications (1st Edn.). Tata McGraw-Hill, New Delhi 2000.
  • [3] Kumar D., Prasad L.: Performance analysis of three side’s solar air heater having roughness elements as a combination of multiple-v and transverse wire on the absorber plate. Arch. Thermodyn. 41(2020), 3, 125–146.
  • [4] Al-Joboory H.N.S.: Experimental and theoretical investigation of an evacuated tube solar water heater incorporating wickless heat pipes. Arch. Thermodyn. 41 (2020),3, 3–31.
  • [5] Menni Y., Chamkha A.J., Zidani C., Benyoucef B.: Analysis of thermo-hydraulic performance of a solar air heater tube with modern obstacles. Arch. Thermodyn. 41(2020), 3, 33–56.
  • [6] Kumar V.: Augmentation in heat transfer and friction of three sides over one side dimple roughened solar duct. Arch. Thermodyn. 41(2020), 3, 57–89.
  • [7] Sahu M.K., Matheswaran M.M., Bishnoi P.: Experimental investigation of augmented thermal and performance characteristics of solar air heater ducts due to varied orientations of roughness geometry on the absorber plate. Arch. Thermodyn.41(2020), 3, 147–182.
  • [8] Ghritlahre H.K., Sahu P.K.: A comprehensive review on energy and exergy analysis of solar air heaters. Arch. Thermodyn. 41(2020), 3, 183–222.
  • [9] Ghritlahre H.K., Chandrakar P., Ahmad A.: Solar air heater performance prediction using artificial neural network technique with relevant input variables. Arch. Thermodyn. 41(2020), 3, 255–282.
  • [10] Ghritlahre H.K.: An experimental study of solar air heater using arc shaped wire rib roughness based on energy and exergy analysis. Arch. Thermodyn. 41(2021), 3,115–139.
  • [11] Kumar V., Prasad L.: Thermal performance investigation of three side’s concave dimple roughened solar air heaters. Sol. Energy 188(2019), 361–379.
  • [12] Kumar D., Prasad L.: Analysis on optimal thermohydraulic performance of solar air heater having multiple V-shaped wire rib roughness on absorber plate. Int. Energy J.18(2018), 153–170.
  • [13] Holman J.P.: Experimental Method for Engineers. McGraw-Hill, New York 2007.
  • [14] Prasad B.N.: Thermal performance of artificially roughened solar air heaters. Sol. Energy 91(2013), 59–67.
  • [15] Prasad B.N., Saini J.S.: Effect of artificial roughness on heat transfer and friction factor in a solar air heater. Sol. Energy 41(1988), 6, 555–60.
  • [16] Kumar D., Prasad L.: Heat transfer augmentation of various roughness geometry used in solar air heaters. Int. J. Mech. Eng. Technol. 12(2017), 8, 491–508.
  • [17] Zidani C., Benyoucef B., Didi F., Guendouz, N.: Simulation and numerical analysis of a rectangular pipe with transversal baffle – comparison between zigzag and plane baffles. Arch. Thermodyn. 41(2020), 4, 269–283.
  • [18] Kumar D., Prasad L.: Thermo-hydraulic performance of solar air heater having multiple V-shape rib on absorber plates. Carbon-Sci. Tech. 10(2018), 1, 39–50.
  • [19] Daghsen K., Lounissi, D., Bouaziz, N.: A universal model for solar radiation exergy accounting: Case study of Tunisia. Arch. Thermodyn. 43(2022), 2, 97–118.
  • [20] Kumar A., Layek A.: Energetic and exergetic performance evaluation of solar air heater with twisted rib roughness on absorber plate. J. Clean. Prod. 232 (2019),617–628.
  • [21] Behura A.K., Prasad B.N., Prasad L.: Heat transfer friction factor and thermal performance of three sides artificially roughened solar air heaters. Sol. Energy 130(2016), 46–59.
  • [22] Karwa R., Chitoshiya G.: Performance study of solar air heater having v-down discrete ribs on absorber plate. Energy 55(2013), 939–955.
  • [23] Kumar A., Saini R.P., Saini J.S.: Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having multi v-shaped with gap ribs as artificial roughness. Renew. Energ. 58(2013), 151–163.
  • [24] Maithani R., Saini J.S.: Heat transfer and friction factor correlations for a solar air heater duct artificially with v-ribs with symmetrical gaps. Exp. Therm. Fluid Sci. 70(2016), 220–227.
  • [25] Gupta D., Solanki S.C., Saini J.S.: Thermohydraulic performance of solar air heaters with roughened absorber plates. Sol. Energy 61(2000), 33–42.
  • 26] Deo N.S., Chander S., Saini J.S.: Performance analysis of solar air heater duct roughened with multigap V-down ribs combined with staggered ribs. Renew. Energ.91(2016), 484–500.
  • [27] Prasad B.N., Behura A.K., Prasad L.: Fluid flow and heat transfer analysis for heat transfer enhancement in three sided artificially roughened solar air heater. Sol. Energy 105(2014), 27–35.
  • [28] Singh S., Chander S., Saini J.S.: Thermal and effective efficiency based analysis of discrete V down rib roughened solar air heaters. J. Renew. Sust. Energ. 3(2011),023107–023126.
  • [29] American Society of Heating, Refrigerating and Air-Conditioning Engineers: Method of Testing to Determine the thermal performance of solar collectors (ASHRAE Standard 93-97). New York 1977.
  • [30] Hans V.S., Saini R.P., Saini J.S.: Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs. Sol. Energy 84(2010), 898–911.
  • [31] Kumar A., Saini R.P., Saini J.S.: Experimental Investigation on heat transfer and fluid flow characteristics of air flow in a rectangular duct with multi v-shaped rib with gap roughness on the heated plate. Sol. Energy 86(2012), 1733–1749.
  • [32] Aharwal K.R., Gandhi B.K., Saini J.S.: Experimental investigation on heat transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater. Renew. Energ. 33(2008), 585–596.
  • [33] Momin A.M.E., Saini J.S., Solanki S.C.: Heat transfer and friction in solar air heater duct with v-shaped rib roughness on absorber plate. Int. J. Heat Mass Tran. 45(2002),3383–3396.
  • [34] Kline S.J., Mcclintok F.A.: Describing uncertainties in single sample experiment. Mech. Eng. 75(1953), 1, 3–8.
Uwagi
Opracowanie rekordu ze środków MEiN, umowa nr SONP/SP/546092/2022 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2022-2023).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-de1f77a3-4ced-4862-b966-b1143f3e9bab
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.