PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Middle ear prostheses – modelling and simulations

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Konferencja
Jubilee Symposium Vibrations In Physical Systems (25 ; 15-19.05.2012 ; Będlewo koło Poznania ; Polska)
Języki publikacji
EN
Abstrakty
EN
The paper presents planar model of human middle ear, which is described by differential equations of motion and solved numerically using the MD Adams software. First, dynamic behaviour of intact ossicular chain is analysed, next, incus is removed and partial ossicular replacement prosthesis is used to reconstruct middle ear. Then, natural frequencies of the system are analysed as a function of mass and length of the prosthesis.
Rocznik
Tom
Strony
341--346
Opis fizyczny
Bibliogr. 20 poz., rys., wykr.
Twórcy
autor
  • Lublin University of Technology, 36 Nadbystrzycka St., 20-618 Lublin, Poland
Bibliografia
  • 1. A.R. Mőller, Network Model of the Middle Ear, Journal of the Acoustical Society of America 33 (1961) 168-176.
  • 2. J. Zwislocki, Analysis of the Middle-Ear Function. Part I: Input Impedance, Journal of the Acoustical Society of America 34 (1962) 1514-1523.
  • 3. M.E. Ravicz, W.T. Peake, H.H. Nakajima, S.N. Merchant, J.J. Rosowski, Modeling Flexibility in the Human Ossicular Chain: Comparision to Ossicular Fixation Data, in: Gyo K, Wada H (Eds.), Middle Ear Mechanics in Research and Otology, Word Scientific, Singapore, 2004.
  • 4. H.H. Nakajima, M.E. Ravicz, S.N. Merchant, W.T. Peake, J.J. Rosowski, Experimental ossicular fixations and the middle ears response to sound: Evidence for a flexible ossicular chain, Hearing Research 204 (2005) 60-77.
  • 5. B. Feng, R.Z. Gan, Lumped parametric model of the human ear for sound transmission, Biomech Model Mechanobiol 3 (2004) 33-47.
  • 6. M. Iwaniec, D. Marszalik, Vibrations analysis of ossicles mechanism, Vibrations in Physical Systems XXIV (2010) 29-34.
  • 7. M. Bornitz, T. Zahnert, H.J. Hardtke, K.B. Huttenbrink, Identyfication of Parameters for the Middle Ear Model, Audiology & Neuro-Otology 4 (1999) 163-169.
  • 8. C. Dai, T. Cheng, M. W. Wood, R.Z. Gan, Fixation and detachment of superior and anterior malleolar ligaments in human middle ear: Experiment and modeling, Hearing Research 230 (2007) 24-33.
  • 9. A. Eiber, H.-G. Freitag, Burkhardt C., Hemmert W, Maassen M., J. Rodriguez Jorge, H.-P. Zenner, Dynamics of Middle Ear Prostheses - Simulations and Measurements, Audiol Neurootol 4 (1999) 178-184.
  • 10. R.Z. Gan, Q. Sun, Finite element modeling of human ear with external ear canal and middle ear cavity, Second Joint Embs-Bmes Conference 2002, Vols 1-3, Conference Proceedings (2002) 264-265.
  • 11. R.Z. Gan, Q.L. Sun, R.K. Dyer, K.H. Chang, K.J. Dormer, Three-dimensional modeling of middle ear biomechanics and its applications, Otology & Neurotology 23 (2002) 271-280.
  • 12. Q.L. Sun, K.H. Chang, K.J. Dormer, R.K. Dyer, R.Z. Gan, An advanced computeraided geometric modeling and fabrication method for human middle ear, Medical Engineering & Physics 24 (2002) 595-606.
  • 13. Q. Sun, R.Z. Gan, K.H. Chang, K.J. Dormer, Computer-integrated finite element modeling of human middle ear, Biomech Model Mechanobiol 1 (2002) 109-122.
  • 14. H. Taschke, C. Weistenhofer, H. Hudde, A full-size physical model of the human middle ear, Acustica 86 (2000) 103-116.
  • 15. M. Kringlebotn, Network Model for the Human Middle Ear, Scandinavian Audiology 17 (1988) 75-85.
  • 16. H.P. Zenner, H.-G. Freitag, C. Linti, U. Steinhardt, J.R. Jorge, S. Preyer, P.-S. Mauz, M. Surth, H. Planck, I. Baumann, R. Lehner, A. Eiber, Acoustomechanical properties of open TTP titanium middle ear prostheses, Hearing Research 192 (2004) 36-46.
  • 17. Asai M., Heiland K. E., Huber A. M., Goode R. L., Evaluation of a Cement Incus Replacement Prosthesis in a Temporal Bone Model, Acta Otolaryngol (Stockh) 119 (1999) 573-576.
  • 18. M. Asai, A.M. Huber, R.L. Goode, Analysis of the Best Site on the Stapes Footplate for Ossicular Chain Reconstruction, Acta Otolaryngol 119 (1999) 355-361.
  • 19. D.P. Morris, M. Bance, R.G. van Wijhe, M. Kiefte, R. Smith, Optimum Tension for Partial Ossicular Replacement Prosthesis Reconstruction in the Human Middle Ear, The Laryngoscope 114 (2004) 305-308.
  • 20. S. Zhao, N. Hato, R.L. Goode, Experimental study of an adjustable-length titanium ossicular prosthesis in a temporal bone model, Acta Oto-Laryngologica 125 (2005) 33-37.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-dd462401-52ac-4d7d-9757-6710c3bc7425
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.