Background and objective: The purpose of this paper is to provide a method for supporting navigation in bronchoscopy based on measurements of absolute orientation of a tip of a bronchoscope and the length a bronchoscope is pushed in the lumen of an examined bronchial structure. Methods: A hardware solution is designed and developed for collecting the data related to the absolute orientation of a tip of a bronchoscope and the length a bronchoscope is pushed in the lumen of an examined structure. A software which processes these data and visualizes in real-time the actual location of a bronchoscope tip in the lumen of a digital model of the examined structure (i.e. virtual bronchoscopy) is also designed and implemented. Results: A calibration procedure is developed which constitutes a basis for the operation of the proposed system. A phantom of a tree-like structure is build, imitating the anatomy of a bronchial tree, and the proposed method of navigation is tested for the task of navigating in the lumen of the phantom to user-selected target locations. Conclusion: A method has been proposed and tested for Inertial Measurement Unit (IMU)- based support of navigation in bronchoscopy.
Wydawca
Czasopismo
Rocznik
Tom
Strony
273--281
Opis fizyczny
Bibliogr. 9 poz., rys., tab.
Twórcy
autor
- Faculty of Physics, Mathematics and Computer Science, Cracow University of Technology, Krakow, Poland
autor
- Faculty of Physics, Mathematics and Computer Science, Cracow University of Technology, Krakow, Poland
autor
- Faculty of Physics, Mathematics and Computer Science, Cracow University of Technology, ul. Warszawska 24, 31-155 Krakow, Poland
Bibliografia
- [1] Wang KP, Mehta AC, Turner JF, editors. Flexible Bronchoscopy. 2nd ed. Cambridge: Blackwell; 2003.
- [2] Yarmus L, Feller-Kopman D. Bronchoscopes of the twenty-first century. Clin Chest Med 2010;31:19–27.
- [3] Dooms C, Seijo L, Gasparini S, Trisolini R, Ninane V, Tournoy KG. Diagnostic bronchoscopy: state of the art. Eur Respir Rev 2010;19:229–36.
- [4] Tsushima K, Sone S, Hanaoka T, Takayama F, Honda T, Kubo K. Comparison of bronchoscopic diagnosis for peripheral pulmonary nodule under fluoroscopic guidance with CT guidance. Respir Med 2006;100:737–45.
- [5] Eberhardt R, Anantham D, Ernst A, Feller-Kopman D, Herth F. Multimodality bronchoscopic diagnosis of peripheral lung lesions: A randomized controlled trial. Am J Respir Crit Care Med 2007;176:36–41.
- [6] Schwarz Y, Mehta AC, Ernst A, Herth F, Engel A, Besser D, et al. Electromagnetic navigation during flexible bronchoscopy. Respiration 2003;70:516–22.
- [7] Becker H, Herth F, Ernst A, Schwarz Y. Bronchoscopic biopsy of peripheral lung lesions under electromagnetic guidance. J Bronchol 2005;12:9–13.
- [8] Schwarz Y, Greif J, Becker HD, Ernst A, Mehta A. Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images. Chest 2006;124:988–94.
- [9] Michalski D, Tabor Z, Zieliński B. Determining the shift of a bronchoscope catheter from the analysis of a video sequence of a bronchoscope video camera. Biocybern Biomed Eng 2017;37:630–6.