PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Experimental investigation of sandwich panels supported by thin-walled beams under various load arrangements and number of connectors

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Badania doświadczalne płyt warstwowych opartych na belkach cienkościennych dla różnych wariantów obciążenia i liczby łączników
Języki publikacji
EN
Abstrakty
EN
In the paper there the laboratory tests of interaction between thin-walled beams of the Z crosssection and the sandwich panels with PIR foam core are presented. The different numbers of connectors (0, 4, and 8) were used to connect the sandwich panels with the thin-walled beams. Furthermore, the parallel and perpendicular to the longitudinal axis of the thin-walled beam load arrangement was analysed. The research provides a qualitative and quantitative comparison of the mentioned experiments using the ultimate capacity, the deformation capacity, and the stiffness. In the second part of the paper, the numerical analysis of the thin-walled beam was also performed. The beam was modelled as a shell element and loaded in two ways, which corresponded to the loading scenario during laboratory tests (uniformly distributed and concentrated loads). The results of the numerical calculations of the beam without lateral stabilization were compared with the laboratory results of the beam stabilized by the sandwich panels.
PL
W pracy przedstawiono wyniki badan eksperymentalnych układów konstrukcyjnych składających się z płyt warstwowych i belek cienkościennych o przekroju Z ułożonych niesymetrycznie względem siebie. W oparciu o europejskie rekomendacje oraz wcześniejsze badania autorów zakłada się, że w analizowanym układzie belki są stabilizowane bocznie przez płyty warstwowe. Wykonano 11 badań laboratoryjnych, które różniły się między sobą liczbą łączników oraz sposobem przyłożenia obciążenia. W celu połączenia płyt warstwowych z belką cienkościenną użyto 0, 4 lub 8 łączników. Obciążenie przypadające na układ było przyłożone równolegle do belek cienkościennych powodując obciążenie równomiernie rozłożone a prostopadle do belek cienkościennych powodując obciążenie punktowe. Przeprowadzone badania wykazały znaczącą wrażliwość układu na sposób przyłożenia obciążenia względem analizowanych układów konstrukcyjnych. Wykazano, że obciążenie realizowane jako równoległe do długości belki podpierającej płytę pozwala analizowanemu układowi na przeniesienie ponad dwukrotnie większego obciążenia niż w przypadku obciążenia realizowanego w sposób prostopadły do długości belki. Dodatkowo omówiono w pracy mechanizmy zniszczenia układu w zależności od sposobu jego obciążenia. Zbadano również wpływ liczby łączników na całkowitą nośność analizowanego układu. Wykazano znaczący wzrost nośności układu przy zwiększającej się liczbie łączników. Zwiększenie liczby łączników łączących belki cienkościenne z płytami warstwowymi wiązało się również z powstaniem złożonym mechanizmami zniszczenia układu. Uzupełnieniem przeprowadzonych badań eksperymentalnych było wykonanie symulacji numerycznych belek cienkościennych niestężonych poszyciem. Belki zamodelowane zostały jako elementy powłokowe obciążone na dwa sposoby: obciążeniem równomiernie rozłożonym na pasie górnym belki oraz siłą skupioną w środku rozpiętości belki. Otrzymane wyniki oraz mechanizmy zniszczenia porównano z wynikami laboratoryjnymi belki stężonej płytą warstwową. Wykazano, że belka niestężona płytą warstwową wykazuje prawie dwukrotnie niższą nośność niż belka stężona.
Rocznik
Strony
389--402
Opis fizyczny
Bibliogr. 18 poz., il., tab.
Twórcy
  • Poznan University of Technology, Faculty of Civil and Transport Engineering, Poznań, Poland
  • Poznan University of Technology, Faculty of Civil and Transport Engineering, Poznań, Poland
Bibliografia
  • [1] EN 1993-1-3: Design of Steel Structures. Part 1-3: General rules - Supplementary rules for cold-formed members and sheeting. Brussels, 2001.
  • [2] S. Kaepplein, T. Misiek, T. Ummenhofer, “Aussteifung und Stabilisierung von Bauteilen und Tragwerken durch Sandwichelemente (Bracing and stabilisation by sandwich panels)”, Der Stahlbau, 2010, vol. 79, no. 5, pp. 336-344; DOI: 10.1002/stab.201001324.
  • [3] S. Kaepplein, T. Ummenhofer, “Querkraftbeanspruchte Verbindungen von Sandwichelementen (Shear loaded fastenings of sandwich panels)”, Der Stahlbau, 2011, vol. 80, no. 8, pp. 600-607; DOI: 10.1002/stab.201101454.
  • [4] M. Georgescu, V. Ungureanu, “Stabilisation of continuous Z-purlins by sandwich panels: Full-scale experimental approach”, Thin-Walled Structures, 2014, vol. 81, pp. 242-249; DOI: 10.1016/j.tws.2013.09.017.
  • [5] I. Balázs, J. Melcher, A. Belica, “Experimental Investigation of Torsional Restraint Provided to Thin-walled Purlins by Sandwich Panels under Uplift Load”, Procedia Engineering, 2016, vol. 161, pp. 818-824; DOI: 10.1016/j.proeng.2016.08.718.
  • [6] I. Balázs, J. Melcher, “Influence of Uplift Load on Torsional Restraint Provided to Steel Thin-Walled Purlins by Sandwich Panels”, Procedia Engineering, 2017, vol. 190, pp. 35-42; DOI: 10.1016/j.proeng.2017.05.304.
  • [7] G. De Matteis, R. Landolfo, “Diaphragm action of sandwich panels in pin-jointed steel structures: A seismic study”, Journal of Earthquake Engineering, 2000, vol. 4, no. 3, pp. 251-275; DOI: 10.1080/13632460009350371.
  • [8] Ch. Kunkel, J. Lange, “Beitrag zur aussteifenden Wirkung von Sandwichelementen (Diaphragm effect of sandwich panels)”, Der Stahlbau, 2017, vol. 86, no. 10, pp. 873-879; DOI: 10.1002/stab.201710528.
  • [9] K. Ciesielczyk, R. Studziński, “Experimental and numerical investigation of stabilization of thin-walled Z-beams by sandwich panels”, Journal of Constructional Steel Research, 2017, vol. 133, pp. 77-83; DOI: 10.1016/j.jcsr.2017.02.016.
  • [10] R. Studziński, K. Ciesielczyk, “Connection stiffness between thin-walled beam and sandwich panel”, Journal of Sandwich Structures and Materials, 2019, vol. 21, no. 6, pp. 2042-2056; DOI: 10.1177/1099636217750539.
  • [11] M. Górski, A. Kozłowski, “Behaviour of hot-rolled purlins connected with sandwich panels”, Archives of Civil Engineering, 2021, vol. 67, no. 1, pp. 249-267; DOI: 10.24425/ace.2021.136472.
  • [12] M. Chybiński, Ł. Polus, “Experimental and numerical investigations of aluminium-timber composite beams with bolted connections”, Structures, 2021, vol. 34, pp. 1942-1960; DOI: 10.1016/j.istruc.2021.08.111.
  • [13] M. Chybiński, Ł. Polus, “Mechanical Behaviour of Aluminium-Timber Composite Connections with Screws and Toothed Plates”, Materials, 2022, vol. 15, no. 1; DOI: 10.3390/ma15010068.
  • [14] M. Chybiński, Ł. Polus, “Withdrawal strength of hexagon head wood screws in laminated veneer lumber”, European Journal of Wood and Wood Products, 2022, vol. 80, pp. 541-553; DOI: 10.1007/s00107-022-01797-4.
  • [15] K. Ciesielczyk, R. Studziński, “Influence of type and orientation of thin-walled beams on the interaction effectiveness with sandwich panels”, in Modern Trends in Research on Steel, Aluminium and Composite Structures: Proceedings of the XIV International Conference on Metal Structures. Leiden, Netherlands: Routledge, 2021, pp. 208-214; DOI: 10.1201/9781003132134-24.
  • [16] EN 1993-1-1: Eurocode 3: Design of steel structures - Part 1-1: General rules and rules for buildings. 2005.
  • [17] European Recommendations on the Stabilization of Steel Structures by Sandwich Panels, No. 135, 1st ed. ECCS - European Convention for Constructional Steelwork, 2014, ISBN: 978-92-9147-118-8.
  • [18] prEN 14509-2:2016 Double skin metal faced insulating panels. Factory made products. Specifications. Part 2: Structural applications - fixings and potential uses of stabilization of individual structural elements.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-d7ae3315-0f46-4fa7-9495-a650b2dcec2d
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.