Influence of blocks’ topologies on endothelial shear stress observed in CFD analysis of artery bifurcation

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
It is well known that endothelial shear stress affects occurrence of plaque in arteries. Lack of a method for measuring this physical quantity limits scientific understanding of this phenomenon. Application of numerical methods in this area has considerable amount of experimental verifications in terms of quantities that can be measured (velocity, pressure). On that basis we can rely on the results of endothelial shear stress calculations. The literature mainly documents the application of numerical methods to average geometries. However, arterial bifurcations are patient-specific. Moreover, occurrence of disease significantly complicates the geometry of the arteries and bifurcations. A multiblock concept provides the necessary geometrical flexibility and computational efficiency to generate patientspecific finite element models. For a particular class of problems different topologies of blocks are possible. This paper provides an overview of the possible block topologies required in finite element modeling using multiblock approach. In order to obtain accurate results of endothelial shear stress, two most general topologies are examined by numerical calculations. Favorable topology of the blocks is implemented in in-house software stl2fem.
Rocznik
Strony
97--104
Opis fizyczny
Bibliogr. 31 poz., rys., wykr.
Twórcy
  • University of Kragujevac, Faculty of Engineering, Kragujevac, Serbia
autor
  • University of Kragujevac, Faculty of Engineering, Kragujevac, Serbia
autor
  • Belgrade University, School of Medicine, Belgrade, Serbia
autor
  • University of Kragujevac, Faculty of Engineering, Kragujevac, Serbia
autor
  • Belgrade University, School of Medicine, Belgrade, Serbia
Bibliografia
  • [1] ZHANG Y., BAJAJ C., Adaptive and quality quadrilateral/hexahedral meshing from volumetric data, Computer Methods in Applied Mechanics and Engineering, 2006, Vol. 195, 942–960.
  • [2] ZHANG Y., BAJAJ C., SOHN B.S., 3D finite element meshing from imaging data, The special issue of Computer Methods in Applied Mechanics and Engineering on Unstructured Mesh Generation, 2005, Vol. 194, 5083–5106.
  • [3] LONG Q., XUA X.Y., COLLINS M.W., BOURNE M., GRIFFITH T.M., Magnetic resonance image processing and structured grid generation of a human abdominal bifurcation, Computer Methods and Programs in Biomedicine, 1998, Vol. 56, No. 3, 249–259.
  • [4] KOJIC M., FILIPOVIC N., STOJANOVIC B., KOJIC N., Computer modeling in Bioengineering, John Wiley & Sons Ltd., 2008.
  • [5] RENEMAN R., ARTS T., HOEKS A., Wall Shear Stress – an Important Determinant of Endothelial Cell Function and Structure in the Arterial System in vivo, Journal of Vascular Research, 2006, Vol. 43, 251–269.
  • [6] MARIUNAS M., KUZBORSKA Z., Influence of load magnitude and duration on the relationship between human arterial blood pressure and flow rate, Acta of Bioengineering and Biomechanics, 2011, Vol. 13, No. 2, 67–72.
  • [7] ZARINS C.K., GIDDENS D.P., BHARADVAJ B.K., SOTTIURAI V.S., MABON R.F., GLAGOV S., Carotid bifurcation atherosclerosis. Quantitative correlation of plaque localization with flow velocity profiles and wall shear stress, Circulation Research, 1983, Vol. 53, 502–514.
  • [8] SCHULZ U.G., ROTHWELL P.M., Major Variation in Carotid Bifurcation Anatomy: A Possible Risk Factor for Plaque Development, Stroke – Journal of the American Heart Association, 2001, Vol. 32, 2522–2529.
  • [9] RINDERU P.L., RINDERU E.T., GRUIONU L., BRATIANU C., A FEM Study of Aortic Hemodynamics in the Case of Stenosis, Acta of Bioengineering and Biomechanics, 2003, Vol. 5, No. 2.
  • [10] ZHANG Y., BAJAJ C., XU G., Surface smoothing and quality improvement of quadrilateral/hexahedral meshes with geometric flow, Proceedings of 14th International Meshing Roundtable, 2005, 449–468.
  • [11] GARCIA E., SERON F., BALDASSARRI S., The challenge of hexahedral meshing of arterial geometry, Machine Graphics & Vision International Journal, 2008, Vol. 17, No. 1, 35–55.
  • [12] GEORGE P.L., Automatic mesh generation: application to finite element methods, Wiley, 1991.
  • [13] RUIZ-GIRONÉS E., Structured and Semi-Structured Algorithms for Hexahedral Mesh Generation, Universitat Politècnica de Catalunya, Barcelona, PhD Thesis, 2009.
  • [14] http://www.truegrid.com/
  • [15] GROSLAND N.M., SHIVANNA K.H., MAGNOTTA V.A., KALLEMEYN N.A., DEVRIES N.A., TADEPALLI S.C., LISLE C., IA-FEMesh: An open-source, interactive, multiblock approach to musculoskeletal finite element model development, Computer Methods and Programs in Biomedicine, 2009, Vol. 94, No. 1, 96–107.
  • [16] ZHAO S.Z., ARIFF B., LONG Q., HUGHES A.D., THOM S.A., STANTON A.V., XU X.Y., Inter-individual variations in wall shear stress and mechanical stress distributions at the carotid artery bifurcation of healthy humans, Journal of Biomechanics, 2002, Vol. 35, 1367–1377.
  • [17] SOULIS J., FARMAKIS T., GIANNOGLOU G., LOURIDAS G., Wall shear stress in normal left coronary artery tree, Journal of Biomechanics, 2006, Vol. 39, 742–749.
  • [18] NGUYEN K.T., CLARK C.D., CHANCELLOR T.J., PAPAVASSILIOU D.V., Carotid geometry effects on blood flow and on risk for vascular disease, Journal of Biomechanics, 2008, Vol. 41, 11–19.
  • [19] OWIDA A.A., DO H., MORSI Y.S., Numerical analysis of coronary artery bypass grafts: An overview, Computer Methods and Programs in Biomedicine, 2012.
  • [20] GOUBERGRITS L., AFFELD K., FERNANDEZ-BRITTOY J., FALCON L., Investigation of geometry and atherosclerosis in the human carotid bifurcations, Journal of Mechanics in Medicine and Biology, 2003, Vol. 3, No. 1, 31–48.
  • [21] SHIVANNA K.H., ADAMS B.D., MAGNOTTA V.A., GROSLAND N.M., Towards Automating Patient-Specific Finite Element Model Development, Proceedings of the Computational Biomechanics for Medicine Workshop at MICCAI, 2006.
  • [22] SHIRSAT A., GUPTA S., SHEVARE G.R., Generation of multiblock topology for discretization of three-dimensional domains, Computers & Graphics, 1999, Vol. 23, 45–57.
  • [23] BLAGOJEVIĆ M., STL2FEM – Software for automatic mesh generation of patient-specific artery bifurcations, University of Kragujevac, Faculty of Engineering, Kragujevac, Serbia, 2011.
  • [24] BLAGOJEVIĆ M., NIKOLIĆ A., ŽIVKOVIĆ M., Visualization of field of fluid flow calculated by fem software PAK-F in postprocessing software ParaView, [in:] YU INFO 2012, Kopaonik, Serbia, 2012.
  • [25] BATHE K.J., Finite element procedures in engineering analysis, Englewood Cliffs, Prentice-Hall, New Jersey, USA, 1996.
  • [26] KOJIĆ M., FILIPOVIĆ N., ŽIVKOVIĆ M., SLAVKOVIĆ R., GRUJOVIĆ N., PAK-F, Program for FE Analysis of Fluid Flow with Heat Transfer, University of Kragujevac, Faculty of Mechanical Engineering, Laboratory for Engineering Software, Kragujevac, Serbia, User’s Manual, 1999.
  • [27] KOJIĆ M., SLAVKOVIĆ R., ŽIVKOVIĆ M., GRUJOVIĆ N., Finite element method I – Linear analysis, (in Serbian), 1st ed., Kragujevac, Serbia: University of Kragujevac, Faculty of Mechanical Engineering, 1998.
  • [28] PERKTOLD K., RESCH M., FLORIAN H., Pulsatile non-Newtonian flow characteristics in a tree-dimensional human carotid bifurcation model, Journal of Biomechanical Engineering, 1991, Vol. 113, 464–475.
  • [29] PERKTOLD K., RESCH M., PETER O., Three-dimensional numerical analysis of pulsatile flow and wall shear stress in the carotid artery bifurcation mode, Journal of Biomechanics, 1991, Vol. 24, 409–420.
  • [30] STONE P.H., FELDMAN C., In vivo assessment of the risk profile of evolving individual coronary plaques: A step closer, Circulation, 2011, Vol. 124, 763–765.
  • [31] GIANNOGLOU G., ANTONIADIS A., KOSKINAS K., CHATZIZISIS Y., Flow and atherosclerosis in coronary bifurcations, EuroIntervention, 2010, Vol. 6, J:J16-J23.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-d79aebc3-152d-409a-a78c-1a11cf24b74b
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.