Calculating power loss in electrical steel taking into account magnetic anisotropy

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Obliczanie strat mocy w blachach elektrotechnicznych z uwzględnieniem anizotropii magnetycznej
Języki publikacji
EN
Abstrakty
EN
Study of anisotropic properties of specific total power loss under axial magnetization and at different frequencies was carried out using a non-standard SST apparatus. Analysis of the relationship between hysteresis components, additional eddy current and magnetic anisotropy justifies considering these components together. The purpose of this article is to propose a method for calculating power losses taking into account the phenomenon of magnetic anisotropy and the magnetizing frequency.
PL
Badanie właściwości anizotropowych jednostkowych strat mocy przy przemagnesowaniu osiowym i różnej częstotliwości przeprowadzono przy użyciu niestandardowego aparatu SST. Analiza zależności pomiędzy składowymi histerezową, dodatkową wiroprądową oraz anizotropią magnetyczną uzasadnia rozpatrywanie tych składowych razem. Celem niniejszego artykułu jest zaproponowanie metody obliczenia strat mocy z uwzględnieniem zjawiska anizotropii magnetycznej i częstotliwości przemagnesowania.
Rocznik
Strony
100--103
Opis fizyczny
Bibliogr. 14 poz., wykr.
Twórcy
autor
  • Politechnika Częstochowska, Instytut Elektroenergetyki, Al. Armii Krajowej 17, 42-200 Częstochowa
Bibliografia
  • [1] Pluta W.A., Angular properties of specific total loss components under axial magnetization in grain-oriented electrical steel. IEEE Trans. on Magn., Vol. 52(4), 2016, pp. 6300912
  • [2] IEC 404-3:1999; Magnetic materials. Methods of measurements of soft magnetic properties of electrical steel and type with the use of single sheet tester
  • [3] Bozorth R., Ferromagnetism. New York, D. van Nostrand Co, 1956
  • [4] Steinmetz C.P., On the law of hysteresis. Procedings of the IEEE. Vol 72, No 2 (1984), pp. 197 - 221 ((originally published in AIEE Transactions, No 9 (1892), pp. 3-51)
  • [5] Yo Sakaki , An approach estimating the number of domain walls and eddy current losses in grain-oriented 3% Si-Fe tape wound cores, IEEE Trans. Magn., 16 (1980), no 4, 569-572
  • [6] Overshoot K. J., The use of domain observations in understanding and improving the magnetic properties of transformer steels. IEEE Trans. Magn., 12 (1976), No 6, 840 - 845
  • [7] Bertotti G., General properties of power losses in soft ferromagnetic materials, IEEE Trans. Magn., vol. 24, no. 1, pp. 621 – 630, Jan. 1988
  • [8] Berttoti G., “Hysteresis in magnetism”, Academic Press, 1998
  • [9] Pluta W.A., Directional properties of loss components in electrical steel sheets, Inter. J. of Applied Electromagnetics and Mechanics, 44(3-4) (2014), pp. 379-385
  • [10] Pluta W.A., Measurements of magnetic properties of electrical steel sheets for the aim of loss separation, Journal of Electrical Engineering, 12, 2011, s. 122-127
  • [11] Chen Y., Pillay P. (2002), An Improved Formula for Lamination Core Loss Calculations in Machines Operating with High Frequency and High Flux Density Excitation, IEEE 37th IAS Annu. Meeting. Vol. 2, pp. 759–766
  • [12] Bunge H.J., Texture and magnetic properties, Textures and Microstructures, 1989, Vol. 11, pp. 75-95
  • [13] Shiozaki M. , Kurosaki Y., Anisotropy of magnetic properties in non-oriented electrical steel sheets, Texture and Microstructures, 1989, vol. 11, pp. 159-170
  • [14] de Campos M. F. , Anisotropy of steel sheets and consequence for Epstein test: I theory. XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 – 22, 2006, Rio de Janeiro, Brazil