Tytuł artykułu
Autorzy
Treść / Zawartość
Pełne teksty:
Identyfikatory
Warianty tytułu
Mikroklimat budynku dla bydła w ujęciu dobowym
Języki publikacji
Abstrakty
The size of all sensible heat balance components in livestock building varies in time, because it depends on time-varying weather factors. On the example of two buildings, sensible heat balance was shown on a daily basis. Measurements carried out in winter and spring in two livestock buildings with usable attics included measurements of air temperature and humidity inside and outside, air velocity in ventilation channels, and wind speed. Measuring devices were designed to record the results of measurements at intervals of 300s. During each such time interval, sensible heat losses by ventilation, heat losses by permeation through the barrier construction, and the amount of sensible heat produced by the animals were calculated. The results of measurements were shown in graphs. The study is important for the development of animal livestock building.
Wielkość wszystkich składników bilansu ciepła jawnego w budynku inwentarskim jest zmienna w czasie ponieważ zależy od zmiennych w czasie czynników pogodowych. Na przykładzie dwóch budynków przedstawiono bilans ciepła jawnego w ujęciu dobowym. Pomiary przeprowadzone w zimie i na wiosnę w dwóch budynkach dla bydła z poddaszem użytkowym obejmowały pomiary temperatury i wilgotności powietrza wewnętrznego i zewnętrznego, prędkości przepływu powietrza w kanałach wentylacyjnych oraz ciśnienia atmosferycznego i prędkości wiatru. Urządzenia pomiarowe zostały zaprojektowane na rejestrację wyników pomiarów w odstępach co 300 s. W każdym z takim przedziale czasowym obliczone zostały straty ciepła jawnego drogą wentylacji, straty ciepła drogą przenikania przez przegrody budowlane oraz ilości ciepła jawnego produkowanego przez zwierzęta. Wyniki pomiarów i obliczeń przedstawiono na wykresach.
Czasopismo
Rocznik
Tom
Strony
41--49
Opis fizyczny
Bibliogr. 12 poz., tab., wykr.
Twórcy
autor
- Department of Environment Shaping and Geodesy, University of Life Sciences in Lublin, Poland
autor
- Department of Environment Shaping and Geodesy, University of Life Sciences in Lublin, Poland
autor
- Department of Agricultural and Transport Machines and Devices, University of Life Sciences in Lublin, Poland
autor
- Department of Agricultural and Transport Machines and Devices, University of Life Sciences in Lublin, Poland
autor
- Department of Biosystem Engineering, Opole University of Technology, Poland
autor
- Department of Biosystem Engineering, Opole University of Technology, Poland
Bibliografia
- Dolezal, P., Dvoracek, J., Dolezal, J., Cermakova, J., Zeman, L., Szwedziak, K. (2011). Effect of feeding yeast culture on ruminal fermentation and blood indicators of Holstein dairy cows. Acta Veterinaria Brno, 80, 139-145.
- Głuski, T. (2007). Designing the microclimate in buildings for cattle. 3rd International Conference TAE 2007. TiAE 2007. Czech University of Life Sciences Prague, 112-114.
- Głuski, T. (2008). Metody określania temperatury wewnętrznej w budynkach dla bydła. Inżynieria Rolnicza, 2(100), 31-36.
- Głuski, T., Nalepa, T., Marczuk, A. (2014). Analysis of the ventilation air stream size in cattle buildings. Agricultural Engineering, 4(152), 61-70.
- Jones, W.P. (2000). Air Conditioning Engineering. Transferred to Taylor & Francis as of 2012. ISBN: 978-0-7506-5074-8.
- Pedersen, S., Sällvik, K. (2002). Heat and moisture production at animal and house levels. The 4th Report of Working Group on Climatization of Animal Houses. CIGR. Horsens.
- Pedersen, S., Morsing, S., Strom, J. (2005). Simulation of Heat Requirement and Air Quality in Weaner for Three Climate Regions Using CIGR 2002 Heat Production Equations. International Commission of Agricultural Engineering, VII. Manuscript BC 05 001.
- PN-82/B-02402. Ogrzewnictwo - Temperatury obliczeniowe zewnętrzne.
- PN-EN ISO 12831:2006. Instalacje ogrzewcze w budynkach – Metoda obliczania projektowego obciążenia cieplnego.
- Siarkowski, Z., Głuski, T. (2000). Obliczeniowe temperatury zewnętrzne i ich wpływ na bilans cieplny budynku inwentarskiego. Inżynieria Rolnicza, 8(19), 243-248.
- Siarkowski, Z., Głuski, T. (2004). Software for helping the designing of livestock buildings. Part 1. Program fundamentals. Proceeding of the International Conference. Praga 10-11.06.2004, 228-233.
- Wolski, L. (2001). Wymiarowanie termiczne obiektów w zabudowie rozproszonej. Warszawa, Oficyna Wydawnicza Politechniki Warszawskiej. ISBN 83-7207-252-3.
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-d624e5ba-a63f-479e-8a59-b93df930939d