Bacterial aerosol occurring in atmospheric air in Gliwice, Upper Silesia, Poland

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The aim of this work is to present the results of qualitative and quantitative analysis of airborne bacteria in the polluted urban atmosphere in Gliwice. The samples of airborne bacteria were collected using 6-stage Andersen cascade impactor (with aerodynamic cutoff diameters 7.0; 4.7; 3.3; 2.1; 1.1; and 0.65 μm). Additionally, the mean level of concentration of airborne solid particles was determined using the particle counter. The size distribution of the bacteria aerosol in winter and spring was also obtained. It has been found that the averaged airborne bacteria level in Gliwice in winter was 89 CFU/m3m (geometric mean) and was elevated in spring more than five times. The main peak of the size-distributions in winter was located in the bacteria size range from 1.1 to 2.1 μm while in the spring the peak was shifted into larger bacterial particles. Concentration of coarse bacterial particles was highly correlated with the concentration of coarse particles of atmospheric particulate matter. The dominant groups of bacteria isolated from the atmospheric air in Gliwice were nonsporing Grampositive rods.
PL
Celem pracy jest przedstawienie wyników analizy jakościowej i ilościowej bakterii zawieszonych w powietrzu zanieczyszczonej atmosfery miejskiej w Gliwicach. Próbki obecnych w powietrzu bakterii były pobierane przy pomocy 6-stopniowego impaktora kaskadowego Andersena (o średnicach odcięcia na poszczególnych stopniach wynoszących odpowiednio 7.0; 4.7;3.3; 2.1; 1.1; oraz 0.65 μm). Ponadto, przy pomocy licznika cząstek, wyznaczono średnią wartość stężenia zawieszonych w powietrzu cząstek pyłu. Otrzymano także rozkłady ziarnowe aerozolu bakteryjnego w zimie i na wiosnę. Wykazano, że średni poziom bakterii w powietrzu Gliwic (średnia geometryczna) wynosił w zimie 89 CFU/m3, a w lecie wzrósł ponad pięciokrotnie. W zimie główny pik stężeń rozkładu ziarnowego znajdował się w przedziale wielkości bakterii od 1.1 do 2.1 μm, a okresie wiosny był przesunięty w stronę większych cząstek bakteryjnych. Stężenie grubych cząstek bakteryjnych było silnie skorelowane ze stężeniem grubych cząstek pyłu w atmosferze. Dominującą grupą bakterii wyizolowanych z powierza atmosferycznego w Gliwicach były niezarodnikujące pałeczki Gram-dodatnie.
Rocznik
Strony
61--66
Opis fizyczny
Bibliogr. 11 poz.
Twórcy
  • Faculty of Energy and Environmental Engineering, Silesian University of Technology, 2 Akademicka St., 44-100 Gliwice, Poland
autor
  • Faculty of Energy and Environmental Engineering, Silesian University of Technology, 2 Akademicka St., 44-100 Gliwice, Poland
autor
  • Faculty of Energy and Environmental Engineering, Silesian University of Technology, 2 Akademicka St., 44-100 Gliwice, Poland
Bibliografia
  • [1] Nevalainen A., Willeke K., Liebhaber F., Pastuszka J., Burge H., Henningson E.; Bioaerosol sampling. (In:) Aerosol Measurement:Principles, Techniques and Applications (Editors: K. Willeke and P. Baron), Van Nostrand Reinhold, New York, N.Y., 1993; p.471-492.
  • [2] Libudzisz Z. Kowal K.; Mikrobiologia techniczna (Technical microbiology). Wydawnictwo Politechniki Łódzkiej, 2000 (in Polish).
  • [3] Kołwzan B., Adamiak W., Grabas K., Pawełczyk A.; Podstawy mikrobiologii w ochronie środowiska (Fundamentals of microbiology in environmental protection). Oficyna Wydawnicza Politechniki Wrocławskiej, Wrocław, 2006 (in Polish).
  • [4] Nevalainen A., Pastuszka J., Liebhaber F., Willeke K.; Performance of bioaerosol samplers: collection char acteristics and sampler design consideration. Atmospheric Environment, Vol.26A, 1992; p.531-540.
  • [5] Seedorf J., Hartung J., Schröder M., Linkert K.H., Metz J.H.M., Groot Koerkamp P.W.G., Uenk G.H.; Concentrations and emissions of airborne endotoxins and microorganisms in livestock buildings in Northern Europe. Journal of Agricultural Engineering Research Vol.70, No.1, 1998; p.97-109.
  • [6] Haas D., Galler H., Luxner J., Zarfel G., Buzina W., Friedl H., Marth E., Habib J., Reinthaler F. F.; The concentrations of culturable microorganisms in relation to particulate matter in urban air. Atmospheric Environment Vol.65, 2013; p.215-222.
  • [7] Pastuszka J.S., Paw U K.T., Lis D.O., Wlazło A., Ulfig K.; Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland. Atmospheric Environment, Vol.34, 2000; p.3833-3842.
  • [8] Owen M.K., Ensor D.S., Sparks L.E.; Airborne particle sizes and sources found in indoor air. Atmospheric Environment, Vol.26A, 1992; p.2149-2162.
  • [9] Chanda S.; Implications of aerobiology in respiratory allergy. Annals of Agricultural and Environmental Medicine, Vol.3, 1996; p.157-164.
  • [10] Chi M.-Ch., Li Ch.-Sh.; Fluorochrome in monitoring atmospheric bioaerosol and correlations with meteorological factors and air pollutants. Aerosol Science and Technology, Vol.41, 2007; p.672-678.
  • [11] Fang Z., Quyang Z., Zheng H., Wang X.; Concentration and size distribution of culturable airborne microorganisms in outdoor environment in Beijing, China. Aerosol Science and Technology, Vol.42, 2008; p.325-334.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-d622af48-370a-4d77-b07e-c5549dc49877
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.