Identyfikatory
Warianty tytułu
Ocena nośności i wzmacnianie konstrukcji żelbetowych pracujących w środowisku agresywnym chemicznie
Języki publikacji
Abstrakty
The paper presents a case of an industrial building in the chemical works, in which intensive production processes caused corrosion and weakened structural members. The results of investigations and static strength analysis are provided. They were necessary to assess the reliability of the structure operating under chemical corrosion conditions corresponding to the XA exposure class. The repair plan, already implemented, together with selected components of the building structural upgrade design are presented.
Czasopismo
Rocznik
Tom
Strony
224--228
Opis fizyczny
Bibliogr. 4 poz., fot., rys., tab.
Twórcy
autor
- Kielce University of Technology
autor
- Kielce University of Technology
Bibliografia
- [1] PN-EN 1990:2004 Eurocode - Basis of structural design.
- [2] PN-EN 206-1:2003 Concrete - Part 1: Requirements, properties, production and conformity.
- [3] PN-B-06265:2004 National supplements PN-EN 206-1:2003 Concrete - Part 1: Requirements, properties, production and conformity.
- [4] PN-EN 1992-1-1:2008 Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings.
Uwagi
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-d39eeb2b-3978-4f58-9f73-21569857c2a9