Experimental Tests of the Vector II Slab in Field Conditions, Slab and Strip Model

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Vector II slab was tested on a natural scale (a slab with a dimension of 6.30 × 6.30 m) and a strip 6.30 m long and 1.20 m wide. The Vector II slab is built by precast panel 60 cm wide, 4 cm thick and 14-20 cm thick concrete overtopping on the construction site. The main purpose of the slab tests on a natural scale was to observe the "faulting" effect and temporary deflections. During the tests, the displacements in the area of the panel joints in the middle of the slab span were recorded. The maximum difference in displacement between adjacent panels of the slab model was 0.16 mm, and the vertical displacement was 1.9 mm. The strip model had no cracks that could indicate a interface cracks between the precast element and the concrete overlay. After completion of the field tests, the load was left on the slab model to verify long-term effects.
Rocznik
Strony
54--69
Opis fizyczny
Bibliogr. 9 poz., fot., rys., wykr.
Twórcy
autor
  • Silesian University of Technology, Gliwice, Poland
  • Silesian University of Technology, Gliwice, Poland
  • Silesian University of Technology, Gliwice, Poland
  • Silesian University of Technology, Gliwice, Poland
  • Wielkopolska Higher School of Social Sciences and Economics, Środa Wielkopolska, Poland
Bibliografia
  • 1. Drobiec, Ł., 2018. VECTOR ceilings concept, planning, designing, performance (in polish). Gliwice. Silesian University of Technology Publisher.
  • 2. Gromysz, K., 2010. Slabs, beams and composite walls of concrete - concrete type (in polish). XXV WPPK. p. 353.
  • 3. Kisiołek, A 2017. The ceiling systems market in Poland. Analysis of selected solutions over the years 2015-2016 (in polish). Środa Wielkopolska. WSSE Publisher.
  • 4. EN 1168:2007 Precast concrete products - Hollow core slabs.
  • 5. EN 13791:2007 Assessment of in-situ compressive strength in structures and precast concrete components.
  • 6. EN 1992-1-1:2005 Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings.
  • 7. Song, J., Kim, S., Ho, L. and Hyo-Gyoung, K. 2009. Load Distribution Factors for Hollow Core Slabs with In-situ Reinforced Concrete Joints. International Journal of Concrete Structures and Materials, Vol. 3, p. 63-69.
  • 8. Starosolski, W. 1998. Transverse work of 2K composite slabs and others. XVI Konferencja Naukowo-Techniczna „Jadwisin 98”, Tom. 2, s. 235-242.
  • 9. Starosolski, W. 2016. Reinforced concrete structures according to Eurocode 2 and related standards Volume 2. Gliwice. PWN Publisher.