Charged projectile spectrometry using solid-state nuclear track detector of the PM-355 type

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
International Conference on Development and Applications of Nuclear Technologies NUTECH 2014 (21-24.09.2014, Warsaw, Poland)
Języki publikacji
EN
Abstrakty
EN
To use effectively any radiation detector in high-temperature plasma experiments, it must have a lot of benefits and fulfill a number of requirements. The most important are: a high energy resolution, linearity over a wide range of recorded particle energy, high detection efficiency for these particles, a long lifetime and resistance to harsh conditions existing in plasma experiments and so on. Solid-state nuclear track detectors have been used in our laboratory in plasma experiments for many years, but recently we have made an attempt to use these detectors in spectroscopic measurements performed on some plasma facilities. This paper presents a method that we used to elaborate etched track diameters to evaluate the incident projectile energy magnitude. The method is based on the data obtained from a semiautomatic track scanning system that selects tracks according to two parameters, track diameter and its mean gray level.
Czasopismo
Rocznik
Strony
591--596
Opis fizyczny
Bibliogr. 23 poz., rys.
Twórcy
  • National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock/Swierk, Poland, Tel.: +48 22 718 0417, Fax: +48 22 779 3481
autor
  • National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock/Swierk, Poland, Tel.: +48 22 718 0417, Fax: +48 22 779 3481
autor
  • National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock/Swierk, Poland, Tel.: +48 22 718 0417, Fax: +48 22 779 3481
  • National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock/Swierk, Poland, Tel.: +48 22 718 0417, Fax: +48 22 779 3481
  • Institute of Plasma Physics and Laser Microfusion, 23 Hery Str., 01-497 Warsaw, Poland and National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock/Swierk, Poland
autor
  • National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock/Swierk, Poland, Tel.: +48 22 718 0417, Fax: +48 22 779 3481
Bibliografia
  • 1. Silk, E. C. H., & Barnes, R. S. (1959). Examination of fission fragment tracks with an electron microscope. Philos. Mag., 4, 970–972.
  • 2. Cartwright, B. G., Shirk, E. K., & Price, P. B. (1978). A nuclear track recording polymer of unique sensitivity and resolution. Nucl. Instrum. Methods, 153, 457–460.
  • 3. Durrani, S. A., & Bull, R. K. (1987). Solid state nuclear track detection. New York: Pergamon Press.
  • 4. Malinowska, A., Szydłowski, A., Sadowski, M. J., Żebrowski, J., Scholz, M., Paduch, M., Jaskóła, M., & Korman, A. (2008). Measurements of fusion-produced protons by means of SSNTDs. Radiat. Meas., 43, S295–S299.
  • 5. Sinenian, N., Rosenberg, M. J., Manuel, M., McDuffee, S. C., Casey, D. T., Zylstra, A. B., Rinderknecht, H. G., Gatu Johnson, M., Séguin, F. H., Frenje, J. A., Li, C. K., & Petrasso, R. D. (2011). The response of CR-39 nuclear track detector to 1–9 MeV protons. Rev. Sci. Instrum., 82, 103303.
  • 6. Szydłowski, A., Malinowska, A., Sadowski, M. J., Jaskóła, M., Korman, A., Wan Wassenhove, G., Bonheure, G., Schweer, B., and TEXTOR Team, Gałkowski, A., & Małek, K. (2008). Measurement of fusion-reaction protons in TEXTOR tokamak plasma by means of solid-state nuclear track detectors of the CR-39/PM-355 type. Radiat. Meas., 43, S290–S294.
  • 7. Szydłowski, A., Badziak, J., Fuchs, J., Kubkowska, M., Parys, P., Rosiński, M., Suchańska, R., Wołowski, J., Antici, P., & Mancic, A. (2009). Application of solid-state nuclear track detectors of the CR-39/PM-355 type for measurements of energetic protons emitted from plasma produced by an ultra-intense laser. Radiat. Meas., 44, 881–885.
  • 8. England, J. B. A. (1974). Techniques in nuclear structure. New York: Wiley-Macmillan Press.
  • 9. Lück, H. B. (1974). Energy spectrometry of protons by means of a dielectric track detector. Nucl. Instrum. Methods, 119, 403–404.
  • 10. Lück, H. B. (1975). Investigations on energy resolution in detecting alpha particles using a cellulose nitrate detector. Nucl. Instrum. Methods, 124, 359–363.
  • 11. Fews, A. P. (1992). Fully automated image analysis of etched tracks in CR-39. Nucl. Instrum. Methods Phys. Res. Sect. B-Beam Interact. Mater. Atoms, 71, 465–478.
  • 12. Fews, A. P. (1992). Flexible analysis of etched nuclear particle tracks. Nucl. Instrum. Methods Phys. Res. Sect. B-Beam Interact. Mater. Atoms, 72, 91–103.
  • 13. Santos, N. F., Iunes, P. J., Paulo, S. R., Guedes, S., & Hadler, J. C. (2010). CR-39 alpha particle spectrometry for the separation of the radon decay product 214Po from the thoron decay product 212Po. Radiat. Meas., 45, 823–826.
  • 14. Immè, G., Morelli, D., Aranzulla, M., Catalano, R., & Mangano, G. (2013). Nuclear track detector characterization for alpha-particle spectroscopy. Radiat. Meas., 50, 253–257.
  • 15. Catalog Page Pershore Moulding Company. (1998).
  • 16. Szydłowski, A., Banaszak, A., Czyżewski, T., Fijał, I., Jaskóła, M., Korman, A., Sadowski, M., & Kretschmer, W. (2001). Advantage of PM-355 nuclear track detector in light-ion registration and high temperature plasma diagnostics. Radiat. Meas., 34(1/6), 325–329.
  • 17. Szydłowski, A., Sartowska, B., Banaszak, A., Choiński, J., Fijał, I., Jaskóła, M., Korman, A., & Sadowski, M. J. (2005). Calibration of PM-355 nuclear track detectors, comparison of track diameter diagrams with track depth characteristics. Radiat. Meas., 40, 401–405.
  • 18. Malinowska, A., Szydłowski, A., Jaskóła, M., Korman, A., Malinowski, K., & Kuk, M. (2012). Calibration of new batches and a study of applications of nuclear track detectors under the harsh conditions of nuclear fusion experiments. Nucl. Instrum. Methods Phys. Res. Sect. B-Beam Interact. Mater. Atoms, 281,56–60.
  • 19. Malinowska, A., Szydłowski, A., Jaskóła, M., Korman, A., Sartowska, B., Kuehn, T., & Kuk, M. (2013). Influence of high temperature on solid state nuclear track detector parameters. Rev. Sci. Instrum., 84, 073517–073521.
  • 20. Szydłowski, A., Malinowska, A., Jaskóła, M., Korman, A., Malinowski, K., & Kuk, M. (2013). Calibration studies of the application of nuclear track detectors to the detection of charged particles. Radiat. Meas., 50, 258–262.
  • 21. Malinowska, A., Szydłowski, A., Jaskóła, M., Korman, A., Żebrowski, J., Sartowska, B., Sadowski, M. J., & Badziak, J. (2008). Calibration and application of modern track detectors CR-39/PM355 in nuclear physics and high temperature plasma experiments. Nukleonika, 53(Suppl. 2), S15–S19.
  • 22. Collins, T. J. (2007). ImageJ for microscopy. BioTechniques, 43(Suppl. 1), 25.
  • 23. Dörschel, B., Bretschneiderm, R., Hermsdorf, D., Kadner, K., & Kühne, H. (1999). Measurement of the track etch rates along proton and alpha particle trajectories in CR-39 and calculation of the detection efficiency. Radiat. Meas., 31, 103–107
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-d21e4f65-c4d5-466d-8323-db7acc081251
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.