PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Behavioural assessment on influence of adjacently placed strip footings at different embedment level

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The footings laid in close proximity imposes a definite change in the behaviour of the adjacent footing, subsequently changing the behaviour of the nearby footings. The present study emphasises the behaviour of the nearby strip footings embedded at a different level by adopting the commercially available finite element analysis program, ABAQUS. The load-settlement behaviour, ultimate bearing capacity (UBC), and the failure patterns of adjacent strip footings are assessed by considering the Mohr-Coulomb failure criterion. The UBC is of the nearby footings (left and right) are estimated and represented in terms of interference factors (ξξL/ξξR) defined as the UBC of a footing in the presence of adjacent footing to that of same considered for equivalent isolated footing. The results reveal that a significant influence of the adjacent footing is experienced when the spacing between the footings (S/B) is lesser, and they behave as the single footing of greater width at S/B = 0.25 irrespective of the level of embedment depth. Furthermore, the influence of interference increases with the increase in the embedment depth of adjacent footing. It is found that the ξξL is significantly more for a lower level of embedment depth, and the same increases with an increase in the embedment depth of the right footing but on the contrary ξξR decreases. The increase in the peak interference factor, ξξL-max for DL/B = 0.5 is 2.1% and 4.2% when DR/B = 0.75 and DR/B = 1.0, respectively.
Rocznik
Strony
93--103
Opis fizyczny
Bibliogr. 36 poz.
Twórcy
  • Assistant Prof.; Department of Civil Engineering, BMS Institute of Technology and Management, Bengaluru-560064, Karnataka, India
  • Assistant Prof.; Department of Civil Engineering, Indian Institute of Technology (ISM), Dhanbad, Dhanbad, Jharkhand, India
autor
  • Assistant Prof.; Department of Civil and Environmental Engineering, Birla Institute of Technology, Mesra, Ranchi-835215, Jharkhand, India
autor
  • Assistant Prof.; Department of Civil Engineering, BMS Institute of Technology and Management, Bengaluru-560064, Karnataka, India
Bibliografia
  • [1] Stuart, J.G. (1962). interference between foundations, with special reference to surface footings in sand, Geotechnique, 12(1), 15-22.
  • [2] Kumar, J. and Bhattacharya, P. (2013). Bearing capacity of two interfering strip footings from lower bound finite elements limit analysis, International Journal for Numerical and Analytical Methods in Geomechanics, 37(5), 441-452.
  • [3] Yang, F., Zheng, X. C., Sun, X. L., and Zhao, L. H. (2017). Upper-bound analysis of N and failure mechanisms of multiple equally spaced strip footings. International Journal of Geomechanics, 17(9), 06017016.
  • [4] Biswas, N. and Ghosh, P. (2018). Interaction of adjacent strip footings on reinforced soil using upperbound limit analysis, Geosynthetics International 25(6), 599-611.
  • [5] Schmüdderich, C., Alimardani Lavasan, A., Tschuchnigg, F., and Wichtmann, T. (2020). Behavior of nonidentical differently loaded interfering rough footings. Journal of Geotechnical and Geoenvironmental Engineering, 146(6), 04020041.
  • [6] Das, S., Halder, K., & Chakraborty, D. (2021). Bearing capacity of interfering strip footings on rock mass. Geomechanics and Geoengineering, 1-13.
  • [7] Shamloo, S., & Imani, M. (2021). Upper bound solution for the bearing capacity of two adjacent footings on rock masses. Computers and Geotechnics, 129, 103855.
  • [8] Ghazavi, M. and Lavasan, A.A. (2008). Interference effect of shallow foundations constructed on sand reinforced with geosynthetics, Geotextiles and Geomembranes, 26(5), 404-415.
  • [9] Mabrouki, A., Benmeddour, D., Frank, R. and Mellas, M. (2010). Numerical Study of the bearing capacity for two interfering strip footings on sands, Computers and Geotechnics, 37(4), 431-439.
  • [10] Lavasan, A.A., Ghazavi, M. and Schanz, T. (2017). Analysis of interfering circular footings on reinforced soil by physical and numerical approaches considering strain-dependent stiffness, International Journal of Geomechanics, 17(11), 04017096.
  • [11] Nainegali, L.S., Basudhar, P.K. and Ghosh, P. (2018). Interference of strip footings resting on nonlinearly elastic foundation bed: a finite element analysis, Iranian Journal of Science and Technology, Transactions of Civil Engineering, 42(2), 199-206.
  • [12] Nainegali, L.S., Basudhar, P.K. and Ghosh, P. (2019). Interference of proposed footing with an existing footing resting on nonlinearly elastic dense and loose cohesionless soil bed, European Journal of Environmental and Civil Engineering, 1-18.
  • [13] Zidan, A.F. and Mohamed, M. (2019). Numerical analysis of bearing capacity of multiple strip footing on unreinforced and reinforced sand beds, SN Applied Sciences, 1(11), 1499.
  • [14] Fuentes, W., Duque, J., Lascarro, C. and Gil, M. (2019). Study of the bearing capacity of closely spaced square foundations on granular soils, Geotechnical and Geological Engineering, 37(3), 1401-1410.
  • [15] Ekbote, A.G. and Nainegali, L. (2019). interference of two closely spaced footings embedded in unreinforced and reinforced soil medium: a finite element approach using ABAQUS, Arabian Journal of Geosciences 12(22), 683.
  • [16] Sekhar, J.C., Sasmal, S.K. and Behera, R.N. (2020). Effect of interference on ultimate bearing capacity of strip footings resting over multi-layered-reinforced soil, Australian Journal of Multi-Disciplinary Engineering, 1-12.
  • [17] Ekbote, A.G. and Nainegali, L. (2021). Finite element analysis of two nearby interfering asymmetric footings embedded in cohesionless foundation medium, Geomechanics and Geoengineering, 16(4), 263-276.
  • [18] Alzabeebee, S. (2021). Interference of Surface and Embedded Three Strip Footings in Undrained Condition. Transportation Infrastructure Geotechnology, 1-18.
  • [19] Kumar, A. and Saran, S. (2004). Closely spaced rectangular footings on reinforced sand, Geotechnical and Geological Engineering, 22(4), 497-524.
  • [20] Ghosh, P., Rajesh, S. and Chand, J.S. (2017). Linear and nonlinear elastic analysis of closely spaced strip foundations using Pasternak model, Frontiers of Structural and Civil Engineering, 11(2), 228-243.
  • [21] Griffiths, D.V., Fenton, G.A. and Manoharan, N. (2006). Undrained bearing capacity of two-strip footings on spatially random soil. International Journal of Geomechanics, 6(6), 421-427.
  • [22] Zheng, G., Zhao, J., and Zhou, H. (2021). Ultimate bearing capacity of two interfering strip footings on sand overlying clay. Acta Geotechnica, 16(7), 2301-2311.
  • [23] Ghosh, P., Basudhar, P. K., Srinivasan, V., and Kunal, K. (2015). Experimental studies on interference of two angular footings resting on surface of two-layer cohesionless soil deposit. International Journal of Geotechnical Engineering, 9(4), 422-433.
  • [24] Gupta, A., and Sitharam, T. G. (2018). Experimental and numerical investigations on interference of closely spaced square footings on sand. International Journal of Geotechnical Engineering, 14(2), 142-150.
  • [25] Saha Roy, S., and Deb, K. (2018). Interference effect of closely spaced footings resting on granular fill over soft clay. International Journal of Geomechanics, 19(1), 04018181.
  • [26] Salamatpoor, S., Jafarian, Y., and Hajiannia, A. (2018). Bearing capacity and uneven settlement of consecutively constructed adjacent footings rested on saturated sand using model tests. International Journal of Civil Engineering, 17(6), 737-749.
  • [27] Dehkordi, F. P., Ghazavi, M., Ganjian, N., and Karim, U. F. (2019). Parametric Study from laboratory tests on twin circular footings on geocell-reinforced sand. Scientia Iranica.
  • [28] Boufarh, R., Abbeche, K., and Abdi, A. (2019). Experimental investigation of interference between adjacent footings on layered cohesionless soil. Soil Mechanics and Foundation Engineering, 56(2), 128-135.
  • [29] Paikaray, B., Das, S. K., and Mohapatra, B. G. (2020). Effect of reinforcement layout on interference effect of square footings on reinforced crusher dust. International Journal of Geotechnical Engineering, 1-10.
  • [30] Lavasan, A. A., Gussmann, P., and Schanz, T. (2015). Assessment of bearing capacity and failure mechanism of interfering strip footings. In Proceedings of the XVI ECSMGE Geotechnical Engineering for Infrastructure and Development, 893-900.
  • [31] Lavasan, A. A., Ghazavi, M., von Blumenthal, A., and Schanz, T. (2018). Bearing capacity of interfering strip footings. Journal of Geotechnical and Geoenvironmental Engineering, 144(3), 04018003.
  • [32] Shokoohi, M., Veiskarami, M., and Hataf, N. (2019). A numerical and analytical study on the bearing capacity of two neighboring shallow strip foundations on sand. Iranian Journal of Science and Technology, Transactions of Civil Engineering, 43(1), 591-602.
  • [33] Chenari, R. J., and Mohafezatkar, A. (2010). Adjacent Building Induced Settlement Reduction in Residential Constructions. Forensic Approach to Analysis of Geohazard Problems.
  • [34] Jayamohan, J., Aishwarya, S., Soorya, S. R., and Balan, K. (2020). Additional Settlement of Footing Due to Loads Acting on Adjacent Foundation. In Geotechnics for Sustainable Infrastructure Development. Springer, Singapore, 1143-1149.
  • [35] Eslami, A., and Moghaddasi, H. (2018). Complications Caused by Neighboring and Building Construction in Urban AreasThree Case Studies. Civil Engineering Research Journal, 5(4), 00143-00152.
  • [36] Shahein, M., and Hefdhallah, A. (2013). Effect of neighboring footings on single footing settlement. In Seventh International Conference on Case Histories in Geotechnical Engineering, 1-9.
Uwagi
PL
Opracowanie rekordu ze środków MEiN, umowa nr SONP/SP/546092/2022 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2022-2023).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-d1aabb74-8f25-4662-841c-a9f5fe803a58
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.