PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
Tytuł artykułu

Wear of working part of surgical drills

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Zużycie części roboczej wierteł chirurgicznych
Języki publikacji
EN
Abstrakty
EN
The paper presents the results ofstudies onthe topography of surgical borers flank after their operation. The studies were carried out on borers made of X39Cr13 martensitic steel, which was subject to heat and surface (plasma nitriding) treatment. Test drilling was performed in beef bones, which were fixed in a vice to ensure appropriate stability, a borer 6 mm in diameter and 160 mm long was used. The studies on the topography of flank comprised studies on roughness, which were carried out by means of a profilographometer designed for 2D and 3D studies on the surface by means of a contact method. The studies were carried out for borers of flank formed by successive drilling cycles.
PL
W artykule przedstawiono wyniki badań topografii powierzchni przyłożenia wierteł chirurgicznych po eksploatacji. Badania przeprowadzono na wiertłach ze stali martenzytycznej X39Cr13, które poddano obróbce cieplnej oraz powierzchniowej (azotowanie jarzeniowe). Testowe wiercenia wykonywano w kościach wołowych, które mocowano w imadle, w celu zachowania odpowiedniej stabilności, użyto wierteł o średnicy 6 mm i długości 160 mm. W ramach badań topografii powierzchni przyłożenia przeprowadzono badania chropowatości, które realizowano z zastosowaniem profilografometru przeznaczonego do badań 2D i 3D powierzchni metodą stykową. Badania przeprowadzono dla wierteł o powierzchni przyłożenia ukształtowanej poprzez kolejne cykle wiercenia.
Rocznik
Strony
99--104
Opis fizyczny
Bibliogr. 15 poz., il.
Twórcy
autor
  • Institute of Materials Engineering, Faculty of Production Engineering and Materials Technology, Czestochowa University of Technology
Bibliografia
  • [1] Gwoździk M., Nitkiewicz Z., Wear resistance of steel designed for surgical instruments after heat and surface treatments, Archives of Metallurgy and Materials, 54 (1), 2009, 241-246.
  • [2] Szafarska M., Iwaszko J., Laser remelting treatment of plasma-sprayed Cr2O3 oxide coatings, Archives of Metallurgy and Materials, 57 (1), 2012, 215-221.
  • [3] Iwaszko J., Surface remelting treatment of plasma-sprayed Al2O3+13wt.% TiO2 coatings, Surface & Coatings Technology, 201, 2006, 3443-3451.
  • [4] Kulesza S., Bramowicz M., A comparative study of correlation methods for determination offractal parameters in surface characterization, Applied Surface Science, 293, 2014, 196-201.
  • [5] Labisz K., Microstructure and mechanical properties of high power diode laser (HPDL) treated cast aluminium alloys, Materials Science and Engineering Technology, 45, 2014, 314-324.
  • [6] Gwoździk M., Evaluation of the surface condition of steel used for surgical instruments by means of atomic forces microscope (AFM), Engineering of Biomaterials, 89‒91, 2009, 74-76.
  • [7] Gwoździk M., Optimization of heat and surface treatment of X39Cr13 steel designated for surgical instruments, [in:] Materials Engineering 2009, Material and exploitation problems in modern Materials Engineering, Stradomski Z. (ed.), Wydawnictwo Wydziału Inżynierii Procesowej, Materiałowej i Fizyki Stosowanej Politechniki Częstochowskiej, Częstochowa 2009, 73-93.
  • [8] Gwoździk M., Nitkiewicz Z., Topography of X39Cr13 steel surface after heat and surface treatment, Optica Applicata, 39 (4), 2009, 853-857.
  • [9] Jagielska-Wiaderek K., Depth-profiles of corrosion properties of carbonitrided AISI 405 steel, Archives of Metallurgy and Materials, 57 (2), 2012, 637-642.
  • [10] Klimecka-Tatar D., Radomska K., Pawłowska G., Corrosion Characteristics in Alkaline, and Ringer Solution of Fe68-xCoxZr10Mo5W2B15 Metalic Glasses, Journal of the Balkan Tribological Association, 21 (1), 2015, 204-210.
  • [11] Augustin G., Zigman T., Davila S., Udilljak T., Staroveski T., Brezak D., S. Babic S., Cortical bone drilling and thermal osteonecrosis, Clinical Biomechanics, 27, 2012, 313-325.
  • [12] Albertini M., Herrero-Climent M., Lázaro P., Rios J.V., Gil F.J., Comparative study on AISI 440 and AISI 420B stainless steel for dental drill performance, Materials Letters, 79, 2012, 163-165.
  • [13] Marciniak J., Biomateriały w chirurgii kostnej, Wyd. Politechniki Śląskiej, Gliwice 1992 [in Polish].
  • [14] Paszenda Z., Tyrlik-Held J., Instrumentarium Chirurgiczne, Wyd. Politechniki Śląskiej, Gliwice 2003 [in Polish].
  • [15] Liu Y., Huang J., Niinomi M., Li H., Inhibited grain growth in hydroxyapatite–graphene nanocomposites during high temperature treatment and their enhanced mechanical properties, Ceramics International, 42, 2016, 11248-11255.
Uwagi
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-d19de93d-982f-4138-ad25-e267b62ceec0
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.