The relationship between type of cooling loads and capacity of floor cooling systems

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Floor cooling system capacity heavily depends on the type of cooling loads occurring in the room. In the case of convective cooling the load capacity of the system is small, however, when radiation flux reaches directly the floor surface the system significantly increases productivity. The paper describes results of numerical simulations that determine the system capacity depending on the type of cooling load for the fixed assumptions of utility. It also sets out the maximum system performance while maintaining a minimum temperature of the floor of 20°C.
Rocznik
Tom
Strony
117--124
Opis fizyczny
Bibliogr. 9 poz., rys.
Twórcy
autor
  • Poznan University of Technology Faculty of Civil and Environmental Engineering
Bibliografia
  • 1. CAUSONEA F., BALDINB F., OLESEN B.W., CORGNATIA S., Floor heating and cooling combined with displacement ventilation: Possibilities and limitations, Energy and Buildings 42 (2010) 2338-2352.
  • 2. Górka A., Odyjas A., Numerical model of floor cooling system, XIII International Conference : Air & Heat - Water & Energy 2011, Wrocław-Kudowa, 2011.
  • 3. ODYJAS A., GÓRKA A., Określanie obciążeń chłodniczych w radiacyjnych systemach chłodzenia pomieszczeń, XII International Conference : Air conditioning protection and district heating 2008, Wrocław-Szklarska Poręba, 2008, PZITS, 327- 332.
  • 4. ODYJAS A., The relation between type of cooling loads and capacity of cooling floor system, XIII International Conference : Air & Heat - Water & Energy 2011, Wrocław-Kudowa, 2011.
  • 5. OLESEN B.W., Possibilities and limitation of radiant floor cooling. ASHRAE Transaction: Reserch 103, 1997, 42-48.
  • 6. OLESEN B.W., Thermal comfort requirement for floors occupied by bare feet. ASHRAE Transactions 83 (2), 1977.
  • 7. SIMMONDS P., HOLST S., REUSS S., GAW W., Using radiant cooled floors to condition large spaces and maintain comfort conditions. ASHRAE Transaction 106 Pt. 1 (2000), pp. 695-701.
  • 8. SONG D., KIM T., SONG S., HWANG S., LEIGH S.B., Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation, Applied Thermal Engineering 28 (2008) 1299-1311.
  • 9. XING J., XIAOSONG Z., YAJUN L., A calculation method for the floor surface temperature in radiant floor system, Energy and Buildings 42 ( 2010) 1753-1758.