PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
Tytuł artykułu

Carrying capacity of axially loaded hsc columns intersected by NSC slab

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
There are presented and commented in this paper existing code provisions and empirical relationships in a view of results of own experimental investigations. The load transmission mechanism between high strength concrete columns intersected by weaker slab concrete has been considered. Slabs of the specimens were made of normal and lightweight aggregate concrete. One of the examined parameters was an effort grade of the concrete slab in punching shear on the column load carrying capacity. No significant effect of this factor was found. However, considerable effect of concrete type of which slab was made was noted. Even similar concrete strengths of slabs and columns of models, higher load carrying capacity was obtained in case of specimen with normal concrete slab.
PL
W artykule przedstawiono i skomentowano wyniki własnych badań eksperymentalnych w świetle obowiązujących przepisów normowych i formuł empirycznych. Rozważano mechanizm przekazywania oddziaływań pomiędzy słupami z betonu o wysokiej wytrzymałości przewarstwionymi słabszym betonem płyty. Płyty badanych modeli wykonane zostały z betonu zwykłego oraz lekkiego betonu kruszywowego. Jeden z rozpatrywanych parametrów stanowił stopień wytężenia płyty stropowej na przebicie na nośność słupa w obrębie połączenia. Stwierdzono brak istotnego wpływu tego czynnika. Zauważono natomiast wpływ rodzaju betonu płyty na nośność badanych modeli. Mimo zbliżonych wytrzymałości betonów płyt i słupów modeli, większą nośność zarejestrowano w przypadku elementu z płytą z betonu zwykłego.
Rocznik
Strony
51--59
Opis fizyczny
Bibliogr. 11 poz., tab., rys., wykr.
Twórcy
autor
  • Department of Concrete Structures, Faculty of Civil Engineering, Architecture and Environmental Engineering, Łódź University of Technology, Politechniki 6, 90-924 Łódź, Poland
autor
  • Department of Concrete Structures, Faculty of Civil Engineering, Architecture and Environmental Engineering, Łódź University of Technology, Politechniki 6, 90-924 Łódź, Poland
autor
  • Department of Concrete Structures, Faculty of Civil Engineering, Architecture and Environmental Engineering, Łódź University of Technology, Politechniki 6, 90-924 Łódź, Poland
Bibliografia
  • [1] ACI 318-11: Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary, American Concrete Institute, 2011; p.154-155
  • [2] AS 3600-2001: Australian Standard, Concrete structures, Standards Australia International, 2001; p. 119
  • [3] CSA A23.3-04: Design of concrete structures, Canadian Standard Association, 2004; p. 46
  • [4] Bianchini A.C., Woods R.E., Kesler C.E.; Effect of Floor Concrete Strength on Column Strength, ACI Journal, Proceedings Vol. 31, No. 11, 1960; p. 1149-1169
  • [5] Gamble W.L., Klinar J.D.; Tests of High-Strength Concrete Columns with Intervening Floor Slabs. Journal of Structural Engineering ASCE, Vol. 117, No. 5, 1991; p. 1462-1476
  • [6] Shu C. C., Hawkins N. M.; Behavior of columns continuous through concrete floors. ACI Structural Journal, Vol. 89, No. 4, 1992; p. 405-416
  • [7] Ospina C.E., Alexander S.D.B.; Transmission of Interior Concrete Column Loads Through Floors, Structural Engineering Report No. 214. Department of Civil and Environmental Engineering University of Alberta, January 1997
  • [8] Tue, N.V., Dietz, J., Shah, A.A.; Vorschlag für die Bemessung der Deckenknoten mit Stützen aus hochfestem Beton (Design Approach for effective Strength of Column-Slab Joints between Columns of High-Strength Concrete). Beton- und Stahlbetonbau, Vol. 100, No. 2, 2005; p. 132-138 (in German)
  • [9] Lee S.C, Mendis P.; Behavior of High-Strength Concrete Corner Columns Intersected by Weaker Slabs with Different Thickness. ACI Structural Journal, Vol. 101, No. 1, 2004; p. 11-18
  • [10] Lee J-H., Yoon Y-S.; Prediction of effective compressive strength of corner columns comprising weaker slab-column joint. Magazine of Concrete Research, Vol. 64, No. 12, 2012; p. 1113-1121
  • [11] EN 1992-1-1: Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings. European Committee for Standardization, 2004; p. 174-175
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-cdb4ea24-39c2-4e17-a974-2b9f22d10f90
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.