Evolution of droplet size distribution in selected nebulizers

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Nebulizers are the class of atomizing devices used to disperse liquids to fine droplets. They found their application in selected technological (typically: small-scale) processes, but their most common use is related to the generation of medicinal aerosols for inhalation. In this work we present the experimental data on the evolution of the size distributions of water droplets generated by two nebulizers (pneumatic and vibrating-mesh) as a result of aerosol mixing with the ambient air. Such a process reflects the real situation, where aerosol emitted from a nebulizer is diluted by additional air sucked by a patient during inhalation. Droplet size distribution was determined by laser diffraction, and these results were further discussed including the data of the aerosol velocity measured by the Laser Doppler Anemometry (LDA). It was demonstrated – as expected - that dilution with the ambient air with moderate humidity results in the intense evaporation of the smallest droplets. However, larger droplet may be saved to a different degree depending on the velocity and geometry of the aerosol cloud emitted from the nebulizer, and on the volume of the diluting air. These parameters have an influence on the droplet coalescence which is another process shaping the droplet size distribution in the studied conditions. The results can deepen the understanding of the mist dynamics which can be applied in various fields of colloidal science and technology.
Rocznik
Strony
32--40
Opis fizyczny
Bibliogr. 39 poz., rys., tab., wykr., wz.
Twórcy
  • Faculty of Chemical and Process Engineering, Warsaw University of Technology, Waryńskiego 1, 00-645 Warsaw, Poland
  • Faculty of Chemical and Process Engineering, Warsaw University of Technology, Waryńskiego 1, 00-645 Warsaw, Poland
Bibliografia
  • AMIRAV, I., NEWHOUSE M.T., 2020. Transmission of Coronavirus by Nebulizer: A Serious, Underappreciated Risk, Can. Med. Assoc. J. 192, E346. DOI:10.1503/cmaj.75066
  • ARI, A., 2020, Practical Strategies for a Safe and Effective Delivery of Aerosolized Medications to Patients with COVID-19, Respir. Med. 167, 105987. DOI: 10.1016/j.rmed.2020.105987
  • BAŁAZY, A., TOIVOLA, M., REPONEN, T., PODGÓRSKI, A., ZIMMER, A., GRINSHPUN, S., 2006. Manikin-Based PerformanceEvaluation of N95 Filtering-Facepiece Respirators Challenged with Nanoparticles, Ann. Occup. Hyg. 50, 259-269. DOI:10.1093/annhyg/mei058
  • BECK-BROICHSITTER, M., KNUEDELER, M.-C., SEEGER, W., SCHMEHL, T., 2014. Controlling the Droplet Size of Formulations Nebulized by Vibrating – Membrane Technology, Eur. J. Pharm. Biopharm. 87, 524-529. DOI: 10.1016/j.ejpb.2014.03.006
  • BECK-BROICHSITTER, M., OESTERHELD, N., 2017, Electrolyte type and nozzle composition affect the process of vibrating-membrane nebulization, Eur. J. Pharm. Biopharm. 119, 11-16. DOI: 10.1016/j.ejpb.2017.05.004
  • BRONIARZ-PRESS, L., SOSNOWSKI, T.R., MATUSZAK, M., OCHOWIAK, M., JABŁCZYŃSKA, K., 2015. The Effect of Shear and Extensional Viscosities on Atomization of Newtonian and Non-Newtonian Fluids in Ultrasonic Inhaler, Int. J. Pharm. 485, 41–49. DOI: 10.1016/j.ijpharm.2015.02.065
  • CARVALHO, T.C., PETERS, J.I., WILLIAMS 3rd, R.O., 2011. Influence of Particle Size on Regional Lung Deposition – What Evidence is There? Int. J. Pharm. 406, 1–10. DOI: 10.1016/j.ijpharm.2010.12.040.
  • CHANDRA, S., FAUCHAIS, P. 2009. Formation of Solid Splats During Thermal Spray Deposition, J. Therm. Spray Tech. 18, 148–180. //doi.org/10.1007/s11666-009-9294-5
  • DEVI, G., SOWMIYA, N., YASODA, K., MUTHULAKSHMI, K., BALASUBRAMANIAN, K. 2020. Review on Application of Drones for Crop Health Monitoring and Spraying Pesticides and Fertilizer, J. Crit. Rev. 7. 667- 672. 10.31838/jcr.07.06.117.
  • DRZYMAŁA, J. 2007. Mineral Processing. Foundations of Theory and Practice of Minerallurgy. Publishing House of Wrocław University of Technology, Wrocław, 2007.
  • EUROPEAN PHARMACOPEIA, 2017. 9th Edition. EDQM, Council of Europe, Strassbourg.
  • FINNEY, J., BUFFO, B., REINECCIUS, C.A., 2002. Effects of Type of Spray Drying and Processing Temperatures on the Physical Properties and Stability of Spray-Dried Flavors, J. Food Sci. 67, 1108-1114. DOI: 10.1111/j.1365- 2621.2002.tb09461.x
  • GEERSTEN, V., LEMAITRE, P., TABARANT, M., CHARTIER, F., 2012. Influence of Design and Operating Parameters of Pneumatic Concentric Nebulizer on Micro-Flow Aerosol Characteristics and ICP-MS Analytical Performances, J. Anal. At. Spectrom. 27, 146-158. DOI: 10.1039/C1JA10255A
  • GHAZANFARI, T., ELHISSI, A. M. A., DING, Z., TAYLOR, K. M. G., 2006. The Influence of Fluid Physicochemical Properties on Vibrating-Mesh Nebulization, Int. J. Pharm. 339, 103-111. DOI: 10.1016/j.ijpharm.2007.02.035
  • GRIMM, 2020, Universal Aerosol Generator. Available at: www.grimm-aerosol.com/products-en/indoor-air- quality/the-aerosol-generator/7811/ (accessed on 10.07.2020).
  • GRADOŃ, L., SOSNOWSKI, T.R., 2014. Formation of Particles for Dry Powder Inhalers, Adv. Powder Technol. 25, 43- 55. DOI: 10.1016/j.apt.2013.09.012
  • GRANT, G., BRENTON, J., DRYSDALE, D., 2000. Fire Supression by Water Sprays, Prog. Energy Combust. Sci. 26, 79-130. DOI: 10.1016/S0360-1285(99)00012-X
  • HASSANI-GANGARAJ, S. M., MORIDI, A., GUAGLIANO, M., 2015. Critical Review of Corrosion Protection by Cold Spray Coatings, Surf. Eng. 31, 803-815. DOI: 10.1179/1743294415Y.0000000018
  • HEO, J., CHOI, M., HONG, J. 2019. Facile Surface Modification of Polyethylene Film via Spray-Assisted Layer-By-Layer Self-Assembly of Graphene Oxide for Oxygen Barrier Properties. Sci. Rep. 9, 2754-2762. DOI:10.1038/s41598-019- 39285-0
  • HINDS, W.C., 1999. Aerosol Technology: Properties, Behavior, and Measurements of Aerosol Particles. 2nd ed. Wiley, New York, NY, USA.
  • INTEC MEDICAL, 2015. Twister Mesh NE-105 – Operation Manual (in Polish). Available at: https://www.intecmedical.pl/inhalator-membranowy-siateczkowy-intec-twister-mesh.html (accessed on 20.07.2020).
  • KRAMEK-ROMANOWSKA, K., ODZIOMEK, M., SOSNOWSKI, T.R., GRADOŃ, L., 2011. Effects of Process Variables on the Properties of Spray-Dried Mannitol and Mannitol/Disodium Cromoglycate Powders Suitable for Drug Delivery by Inhalation, Ind. Eng. Chem. Res. 50, 13922–13931. DOI: 10.1021/ie2006998/
  • LE BRUN, P.P., DE BOER, A.H., HEIJERMAN, H.G., FRIJLINK, H.W., 2000. A Review of the Technical Aspects of Drug Nebulization, Pharm. World Sci. 22, 75-81. DOI:10.1023/a:1008786600530
  • LEFEBVRE, A.H., McDONELL, V.G., 2017. Atomization and Sprays. 2nd Ed. CRC Press, Boca Raton, FL, USA.
  • MARIANECCI, C., DI MARZIO, L., RINALDI, F., CARAFA, M., ALHAIQUE, F., 2011. Pulmonary Delivery: Innovative Approaches and Perspectives, J. Biomater. Nanobiotechnol., 2, 567-575. DOI: 10.4236/jbnb.2011.225068
  • McCALLION, O.N.M., TAYLOR, K.M.G., THOMAS, M., TAYLOR, A.J.. 1995. Nebulization of Fluids of Different Physicochemical Properties with Air-Jet and Ultrasonic Nebulizers, Pharm. Res. 12, 1682-1688. DOI: 10.1023/a:1016205520044
  • MUÑOZ, V., GONZALEZ, J.S., MARTINEZ, M.A., ALVAREZ, V.A., 2017. Functional Textiles for Skin Care by Active Substance Encapsulation, J. Textile Eng. Fashion Technol. 2, 538-545. DOI: 10.15406/jteft.2017.02.00082
  • OCHOWIAK, M., KASPERKOWIAK, A., DOLIGALSKI, M., SOSNOWSKI, T.R., MATUSZAK, M., WŁODARCZAK, S., MARKOWSKA, M., KRUPIŃSKA, K., JABŁCZYŃSKA, K., 2019. The Thermostated Medical Jet Nebulizer: Aerosol Characteristics. Int. J. Pharm. 567, 118475. DOI: 10.1016/j.ijpharm.2019.118475
  • PARI, 2011. Available at: https://www.pari.com/int/products/inhalation-devices-for-the-lungs/pari-boy-sx-int/ (accessed on: 20.07.2020).
  • PIROŻYŃSKI, M., SOSNOWSKI, T.R., 2016. Inhalation Devices: from Basic Science to Practical Use, Innovative vs Generic Products, Expert Opin. Drug Del. 13, 1559-1571. DOI: 10.1080/17425247.2016.1198774
  • PODGÓRSKI, A., GRADOŃ, L., MOSKAL, A., 2006. Evolution of the Initial Size Distribution of Aerosol Particles in a Nebulizer System Used in the Lung Therapy, Inż. Chem. Proc. 27, 519-534 (no DOI).
  • PRITCHARD, J.N., HATLEY, R.H.M., DENYER, J., VON HOLLEN, D. 2018. Mesh Nebulizers Have Become the First Choice for New Nebulized Pharmaceutical Drug Developments. Ther. Deliv. 9, 131-136. DOI: 10.4155/tde- 2017-0102
  • ROTHE, H., FAUTZ, R., GERBER, E., NEUMANN, L., RETTINGER, K., SCHUH, W., GRONEWOLD, C., 2011. Special Aspects of Cosmetic Spray Safety Evaluations: Principles on Inhalation Risk Assessment, Toxicol. Lett. 205. 97- 104. 10.1016/j.toxlet.2011.05.1038.
  • SHEEHAN, M.J., PETERS, T.M., CENA, L., O'SHAUGHNESSY, P.T., GUSSMAN, R.A., 2009. Generation of Nanoparticles with a Nebulizer-Cyclone System, Aerosol Sci. Techn. 43, 1091-1098. DOI:10.1080/02786820903173687
  • SOSNOWSKI, T.R., RAPIEJKO, P., SOVA, J., DOBROWOLSKA, K., 2020. Impact of Physicochemical Properties of Nasal Spray Products on Drug Deposition and Transport in the Pediatric Nasal Cavity Model, Int. J. Pharm. 574, 118911. DOI: 10.1016/j.ijpharm.2019.118911
  • STECKEL, H., ESKANDAR, F., 2003. Factors Affecting Aerosol Performance During Nebulization with Jet and Ultrasonic Nebulizers, Eur. J. Pharm. Sci. 19, 443-455. DOI: 10.1016/s0928-0987(03)00148-9
  • TSE SYSTEMS, 2020. Liquid Aerosol Generator. Available at: www.tse-systems.com/product-details/liquid-aerosol- generator (accessed on 15.07.2020).
  • WANG, L.K., TARICSKA, J.R., HUNG, Y.-T., ELDRIDGE, J.E., HUNG LI, K., 2004. Wet and Dry Scrubbing. In: Wang L. K., Pereira N. C., Hung Y.T. Air Pollution Control Engineering, Humana Press Inc., Totowa, NJ, USA; pp. 197- 305.
  • WOO, M.W., BHANDARI, B., 2013. Spray Drying for Food Powder Production. In: Handbook of Food Powders. Woodhead Publishing Series in Food Science, Technology and Nutrition; pp. 29-56. DOI: 10.1533/9780857098672.1.29
Uwagi
Work supported by NCN project No. 2018/29/B/ST8/00273.