PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Lokalizacja zwarć w linii napowietrznej z estymacją jej parametrów

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
EN
Identification of short-circuits in a power line and estimation of its parameters
Języki publikacji
PL
Abstrakty
EN
The development of GPS-synchronized distributed measurement systems caused a significant progress in the identification of short circuits in overhead power lines for the purposes of inspection and repair. The usage of voltages and currents measured on both ends of a line as inputs for a localizer enhanced the identification of short circuits as opposed to the local measurements. The innovative measurement methods allow for the identification of short-circuits without knowing line parameters and the calculated parameters can be applied, for instance, for protection relay settings management. The deployment of efficient methods of measurement signal transmission over large distances and GPS-based synchronization resulted in the implementation of wide area measurement systems (WAMS) in the power systems, with PMU (Phasor Measurement Unit) being the basic element of such measurement systems.
Rocznik
Strony
46--53
Opis fizyczny
Bibliogr. 8 poz., rys.
Twórcy
  • Politechnika Wrocławska
  • Politechnika Wrocławska
Bibliografia
  • [1] M. M. Saha, J. Iżykowski, E. Rosołowski, Fault Location on Power Networks, Springer, London, 2010.
  • [2] J. Machowski, Zastosowanie rozległych systemów pomiarowych w automatyce przeciwawaryjnej systemu elektroenergetycznego, Przegląd Elektrotechniczny, 2005, R. 81, nr 2, pp. 1–15.
  • [3] A. G. Phadke, J. S. Thorp, Synchronized phasor measurements and their applications, Springer, New York, 2008.
  • [4] Y. Liao, S. Elangovan, Unsynchronized two-terminal transmission-line fault- -location without using line parameters, IEE Proc.-Generation Transmission and Distribution, 2006, vol. 153, issue 6, pp. 639–643.
  • [5] G. Preston, Z. Radojevic, C. H. Kim, V. Terzija, New setting-free fault location algorithm based on synchronized sampling, IET Generation, Transmission & Distribution, 2011, vol. 5, nr 3, pp. 376–383.
  • [6] CPU CU1 – Measurement system for line impedances and k-factors, mutual coupling of parallel lines, ground impedances of large substations, step and touch voltages, coupling of parallel lines into signal cables, OMICRON, http://www.omicron. at/fileadmin/user_upload/files/pdf/en/CP-CU1-Brochure-ENU.pdf .
  • [7] H. W. Dommel, Electro-Magnetic Transients Program. BPA, Portland, Oregon, 1986.
  • [8] M. Zhou, V. Centeno, J. S. Thorp, A. G. Phadke, Calibrating instrument transformers with phasor measurements, electric power components and systems, 2012, 40:14, pp. 1605–1620.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-cab55ae3-50a9-434e-83ca-5ae5dd97351e
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.