Tytuł artykułu

Box coolers as an alternative to existing cooling systems

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The marine Diesel engines cooling systems and its elements were changing similarly to engines construction. Evolution of the cooling systems tends to reduce sea water pipelines inside engine room. Application of a central cooling system with box coolers completely eliminates sea water pipelines from engine room. Now that solution is rarely used on ships. It can be met on smaller ships, whose power output usually does not exceed 5000 kW, for example: tugs, dredgers, barges, supply vessels, fishing vessels, ferries, cargo freighters, reefers, ice breakers, carriers, etc. – operating inland, as well as in open sea navigation. The article presents an example of practical application of the central cooling system with box coolers on the tug running in Gdynia harbour. In author’s opinion, central cooling system with box coolers has a chance to spread out on bigger ships in the future. It will mainly depend on efficiency and reliability of box coolers secure systems. These systems ought to ensure correct operation of a cooling system between ship class dry-dockings. The box coolers used on the presented harbour tug are secured by ICAF system. The article presents also a proposition of solution to the cooling system with box coolers for merchant ship with power output higher up 5000 kW and advantages (disadvantages) of that solution.
Rocznik
Strony
131--136
Opis fizyczny
Bibliogr. 8 poz., rys., tab.
Twórcy
  • Gdynia Maritime University, Department of Marine Power Plant 81-079 Gdynia, ul. Morska 81-87
Bibliografia
  • 1. BALCERSKI A.: Siłownie okrętowe. Publishing House of Gdańsk Technical University, Gdańsk 1986.
  • 2. GIERNALCZYK M., GÓRSKI Z.: Siłownie okrętowe. Akademia Morska w Gdyni, Gdynia 2013.
  • 3. MICHALSKI R.: Siłownie okrętowe. Publishing House of Merchant Maritime University of Szczecin, Szczecin 1996.
  • 4. URBAŃSKI P.: Instalacje okrętów i obiektów oceanotechnicznych. Publishing House of Gdańsk Technical University, Gdańsk 1994.
  • 5. Manuals and project guides of the box coolers producers: GEA BLOKSMA B.V., WEKA.
  • 6. ŻYŁKA Ł.: Analiza eksploatacyjna instalacji chłodzącej statku o mocy napędu 15,000 kW. Masters thesis, Gdynia 2007.
  • 7. Instruction manual ICAF system. Langenboomseweg, 2006.
  • 8. SCHOTTEL manual, Spay/Germany, 2006.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-c944dfa0-59ec-4588-8fb2-9e5bfeaf7df8
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.