Identyfikatory
Warianty tytułu
Właściwości mechaniczne wzmocnionych konsol aluminiowych
Języki publikacji
Abstrakty
The aim of the research is laboratory investigation of aluminium brackets employed to fasten lightweight curtain walls to building facilities. Tensile loads perpendicular to end plates (vertical) were applied here. The author focused on the solutions intended to increase the load-carrying capacity of aluminium brackets applying the plain washer form A (DIN 125; ISO 7089), plain washer with an outer diameter about 3d (DIN 9021; ISO 7093) and additional cover plates (straps) in the location of bolt anchoring on the base plate. The aluminium brackets were tested on a steel base and concrete substrate. The flexibility of anchoring strongly affects the increase of the end plate middle point displacement and movable crosshead displacement.
Przedmiotem przedstawionych w artykule badań są konsole aluminiowe, które są stosowane jako łączniki fasad słupowo-ryglowych z konstrukcją budynku. Konsole wykonano ze stopu aluminium AW-6060 wg PN-EN 573-3:2004, odmiana T66 wg PN-EN 515:1996. W pracy badano wpływ zastosowania w miejscu kotwieni konsol aluminiowych zwykłej stalowej podkładki (typ A), powiększonej stalowej podkładki (typ B) oraz aluminiowych nakładek (tzw. stempli, typ C). Konsole aluminiowe kotwiono do podłoża stalowego i betonowego wykorzystując śruby lub kotwy mechaniczne. Zastosowanie dwóch typów podłoża, do którego kotwiono konsole aluminiowe, umożliwiło ocenę wpływu podatności kotwienia mechanicznego na nośności i sztywności wzmacnianych konsol aluminiowych. Wyniki badań wskazują iż zastosowanie aluminiowych nakładek, usytuowanych pod nakrętkami śrub łączących je z konstrukcją budynku, zwiększa sztywności konsol aluminiowych. Nakładki wzmacniają lokalnie blachy czołowe konsol. Ich zadaniem konstrukcyjnym jest m.in. zmniejszenie ramienia „zginania” c oraz zwiększenie sztywności giętnej blachy czołowej konsoli.
Czasopismo
Rocznik
Tom
Strony
203--216
Opis fizyczny
Bibliogr. 9 poz., il., tab.
Twórcy
autor
- Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gdansk, Poland
Bibliografia
- 1. A. Ambroziak, M.T. Solarczyk, A. Biegus, “Numerical and analytical investigation of aluminium bracket strengthening.” Archives of Civil Engineering, 64(2): 37-54, 2018. DOI: 10.2478/ace-2018-0015
- 2. A. Ambroziak, M.T. Solarczyk, “Incorrect solutions in the field of anchoring in civil engineering.” Materiały Budowlane, 5: 18-19, 2017. DOI: 10.15199/33.2017.05.05
- 3. P. Zoetemeijer, “A design method for the tension side of statically loaded, bolted beam-to-column connections.” Heron 20(1) 1974, Delft University, Delft, Holland.
- 4. R.S. Nair, P.C. Birkemoe, W.H. Munse, “High Strength Bolts Subject to Tension and Prying.” Journal of the Structural Division, ASCE, 100(2): 351-372, 1974.
- 5. CEN (European Committee for Standardization) “Aluminium and aluminium alloys. Extruded rod/bar, tube and profiles. Mechanical properties.” EN 755-2, 2016 Brussels, Belgium.
- 6. EOTA (European Organisation for Technical Assessment) “Guideline for European Technical Approval of kits for external wall claddings part II: Cladding kits comprising cladding components, associated fixings, subframe and possible insulation layer.” ETAG 034, 2012, Brussels, Belgium.
- 7. CEN (European Committee for Standardization) “Concrete – Specification, performance, production and conformity.” EN 206+A1, 2013, Brussels, Belgium.
- 8. K. Kazmierczak, “Review of curtain walls, focusing on design problems and solutions.” Building Enclosure Science & Technology, Portland, April 12-14, BEST2 – Design and Rehabilitation – Session EE4-1, 1-20, 2010. https://cdn.ymaws.com/www.nibs.org/resource/resmgr/BEST/BEST2_008_EE4-1.pdf
- 9. J. Č. Tovarović, N. Šekularac, J. Ivanović-Šekularac, “Problems Associated With Curtain Walls.” Structural Engineering International, 27(3), 413-417, 2017.