PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
Tytuł artykułu

A Simple Liquid Chromatographic Method for the Determination of Tenofovir in Rat Plasma and Its Application to Pharmacokinetic Studies

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The objective of this study was to develop and validate a novel, simple, and selective high-performance liquid chromatographic (HPLC) method with photodiode array detector for the estimation of tenofovir in rat plasma, which can be utilized in analyzing the pharmacokinetic samples from rats. Prior to analysis, an optimized protein precipitation technique was used to extract tenofovir from plasma. The mobile phase for this method comprised of 10 mM ammonium acetate buffer (pH 4) and methanol in the ratio of 97:3 υ/υ. Chromatographic separation of tenofovir was achieved using Spincotech C-18G enabled column (250 × 4.6 mm, 5 μm). Tenofovir was monitored at a wavelength of 260 nm, and the calibration curve was linear in the range of 250–4000 ng mL−1 (R2 = 0.999). High recovery obtained after extraction (97%–101%) of plasma samples precluded the use of an internal standard. Validation studies were performed as per the standard guidelines, and the developed method was accurate, precise, and selective for the determination of tenofovir in the rat plasma. The stability studies performed during the sample pretreatment process and sample storage conditions did not show a quantifiable degradation of tenofovir. Further, this method was able to estimate tenofovir and determine its pharmacokinetic parameters, post IV bolus administration in male Wistar rats. The pharmacokinetic profile of tenofovir followed one compartmental open model.
Rocznik
Strony
597--612
Opis fizyczny
Bibliogr. 31 poz., rys., tab.
Twórcy
autor
  • Pharmacy Department, BITS—Pilani Hyderabad Campus, Jawaharnagar, Ranga Reddy (Dist.), Andhra Pradesh, India
autor
  • Pharmacy Department, BITS—Pilani Hyderabad Campus, Jawaharnagar, Ranga Reddy (Dist.), Andhra Pradesh, India
  • Pharmacy Department, BITS—Pilani Hyderabad Campus, Jawaharnagar, Ranga Reddy (Dist.), Andhra Pradesh, India
  • Pharmacy Department, BITS—Pilani Hyderabad Campus, Jawaharnagar, Ranga Reddy (Dist.), Andhra Pradesh, India
Bibliografia
  • [1] M. Nelson, S. Portsmouth, J. Stebbing, M. Atkins, A. Barr, G. Matthews, D. Pillaya, M. Fisher, M. Bower, and B. Gazzard, AIDS, 17, F7 (2003)
  • [2] M. Foggia, S. Nappa, G. Bonadies, M. Cotugno, G. Di Filippo, F. Borrelli, R. Orlando, and G. Borgia, Anti-Infect. Agents Med. Chem., 7, 285 (2008)
  • [3] M.N. Arimilli, C.U. Kim, J. Dougherty, A. Mulato, R. Oliyai, J.P. Shaw, K.C. Cundy, and N. Bischofberger, Antivir. Chem. Chemother., 8, 557 (1997)
  • [4] H.B. Fung, E.A. Stone, and F.J. Piacenti, Clin. Ther., 24, 1515 (2002)
  • [5] M.R. Nelson, C. Katlama, J.S. Montaner, D.A. Cooper, B. Gazzard, B. Clotet, A. Lazzarin, K. Schewe, J. Lange, C. Wyatt, S. Curtis, S.S. Chen, S. Smith, N. Bischofberger, and J.F. Rooney, AIDS, 21, 1273 (2007)
  • [6] J. Van Gelder, S. Deferme, L. Naesens, E. De Clercq, G. Van Den Mooter, R. Kinget, and P. Augustijns, Drug Metab. Dispos., 30, 924 (2002)
  • [7] J. Van Gelder, M. Witvrouw, C. Pannecouque, G. Henson, G. Bridger, L. Naesens, E. De Clercq, P. Annaert, M. Shafiee, G. Van den Mooter, R. Kinget, and P. Augustijns, Int. J. Pharm., 186, 127 (1999)
  • [8] J. Van Gelder, M. Shafiee, E. De Clercq, F. Penninckx, G. Van den Mooter, R. Kinget, and P. Augustijns, Int. J. Pharm., 205, 93 (2000)
  • [9] J. Van Gelder, S. Deferme, P. Annaert, L. Naesens, E. De Clercq, G. Van den Mooter, R. Kinget, and P. Augustijns, Drug Metab. Dispos., 28, 1394 (2000)
  • [10] T.J. Johnson, K.M. Gupta, J. Fabian, T.H. Albright, and P.F. Kiser, Eur. J. Pharm. Sci., 39, 203 (2010)
  • [11] T. Zhang, T.F. Sturgis, and B.C. Youan, Eur. J. Pharm. Biopharm., 79, 526 (2011)
  • [12] J. Meng, T.F. Sturgis, and B.C. Youan, Eur. J. Pharm. Biopharm., 44, 57 (2011)
  • [13] A.S. Zidan, Z. Rahman, and M.A. Khan, Eur. J. Pharm. Biopharm., 44, 93 (2011)
  • [14] N.L. Rezk, R.D. Crutchley, and A.D.M. Kashuba, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci., 822, 201 (2005)
  • [15] S. Sentenac, C. Fernandez, A. Thuillier, P. Lechat, and G. Aymard, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci., 793, 317 (2003)
  • [16] V. Bezy, P. Morin, P. Couerbe, G. Leleu, and L. Agrofoglio, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci., 821, 132 (2005)
  • [17] V. Jullien, J. Treluyer, G. Pons, and E. Rey, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci., 785, 377 (2003)
  • [18] R.W. Sparidans, K.M.L. Crommentuyn, J.H.M. Schellens, and J.H. Beijnen, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci., 791, 227 (2003)
  • [19] M. Takahashi, Y. Kudaka, N. Okumura, A. Hirano, K. Banno, and T. Kaneda, Biol. Pharm. Bull., 30, 1784 (2007)
  • [20] C. Bennetto-Hood, M.C. Long, and E.P. Acosta, Rapid Commun. Mass Spectrom., 21, 2087 (2007)
  • [21] M.E. Barkil, M. Gagnieu, and J. Guitton, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci., 854, 192 (2007)
  • [22] T. Delahunty, L. Bushman, B. Robbins, and C.V. Fletcher, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci., 877, 1907 (2009)
  • [23] B.H. Jung, N.L. Rezk, A.S. Bridges, A.H. Corbett, and A.D.M. Kashuba, Biomed. Chromatogr., 21, 1095 (2007)
  • [24] R. Nirogi, G. Bhyrapuneni, V. Kandikere, K. Mudigonda, P. Komarneni, R. Aleti, and K. Mukkanti, Biomed. Chromatogr., 23, 371 (2009)
  • [25] N.A. Gomes, V.V. Vaidya, A. Pudage, S.S. Joshi, and S.A. Parekh, J. Pharm. Biomed. Anal., 48, 918 (2008)
  • [26] T. Delahunty, L. Bushman, B. Robbins, and C.V. Fletcher, J. Chromatogr. B Analyt. Technol. Biomed. Life Sci., 830, 6 (2006)
  • [27] D.L. Walters, D.L. Jacobs, J.E. Tomaszewski, and S. Graves, J. Pharm. Biomed. Anal., 19, 955 (1999)
  • [28] International Conference on Harmonization (ICH), Harmonized Tripartite Guideline, Guideline on, Topic Q2B, Notes for Guidelines for Validation of Analytical Procedures: Methodology, The European Agency for the Evaluation of Medicinal Products, Human Medicines Evaluation Unit, Geneva, 1996
  • [29] Guidance for Industry: Bioanalytical Method Validation, U.S. Department of Health and Human Services, Food and Drug Administration, Silver Spring, MD, 2001
  • [30] R.U.E.’t Lam, Anal. Chim. Acta, 659, 68 (2010)
  • [31] E. Schreiber-Deturmeny and B. Bruguerolle, J. Chromatogr. B Biomed. Appl., 677, 305 (1996
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-c7e140dd-b211-4194-9be9-9e3edb2a34d6
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.