PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Influence of the Detector Characteristic on the Result of Sky Temperature Measurement with the Use of Long-Wave Infrared Camera

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
During the temperature measurements by means of infrared camera the temperature of surrounding elements must be known. In the case of thermovision inspections of the objects exposed to open air space, the surroundings consists of two elements, it is the ground and hypothetical sky surface. The sky temperature measured by long-wave IR camera is of apparent character because it expresses the thermal radiation of the sky within the spectral operational range of this camera i.e. 7.5÷13 μm. The abovementioned spectral range is coincident with so called atmospheric window within which the thermal radiation of the sky is relatively low. The emissivity of atmosphere within this window is low in the central part and high near the limits of the aforementioned range. In relation with the detector characteristic of the IR camera it causes underestimation of the measured sky temperature. This work deals with the analysis of influence of the IR camera detector characteristic on the results of determination of sky temperature and its thermal radiation intensity.
Wydawca
Rocznik
Strony
173--175
Opis fizyczny
Bibliogr. 10 poz., tab., wykr., wzory
Twórcy
autor
  • Institute of Thermal Technology, Silesian University of Technology, Konarskiego 22, 44-100 Gliwice, Poland
Bibliografia
  • [1] Awanou C., N.: Clear sky emissivity as a function of the zenith direction. Renewable Energy, vol.13, pp. 227-248, 1998.
  • [2] Dulski R., Sosnowski T., Polakowski H.: A method for modelling IR images of sky and clouds. Infrared Physics & Technology, vol. 54, pp. 53-60, 2011.
  • [3] Kruczek T.: Conditions for the use of infrared camera diagnostics in energy auditing of the objects exposed to open air space at isothermal sky. Archives of Thermodynamics, vol. 36, pp. 67-82, 2015.
  • [4] Kruczek T.: Use of LW infrared camera for measurement of sky thermal radiation. MAaM, vol. 59, pp. 905-908, 2013, [in Polish].
  • [5] Kruczek T.: Determination of annual heat losses from heat and steam pipeline networks and economic analysis of their thermomodernisation. Energy, vol. 62, pp. 120-131, 2013.
  • [6] Minkina W., Dudzik S.: Infrared Thermography - Errors and Uncertainties. John Wiley & Sons, UK, 2009.
  • [7] Orzechowski T., Wciślik S.: Experimental analysis of the drop film boiling at ambient pressure. Energy Conversion and Management, vol. 76, pp. 918-924, 2013.
  • [8] Rothman L. S., Gordon I. E., Barber R., J. et all.: HITEMP, the high-temperature molecular spectroscopic database. Journal of Quantitative Spectroscopy & Radiative Transfer, vol. 111, pp. 2139-2150, 2010.
  • [9] Tissot J.L., Pochic D., Durand A. et al.: Latest developments in microbolometers detector technology. Proc. of VIII-th Conf.– Thermogr. and Thermometry in Infrared TTP 2009, Ustroń, pp. 35-42, 2009.
  • [10] Więcek B., De Mey G.: Thermovision in Infrared. Fundamentals and Applications. Publishing House PAK, Warsaw, 2011 [in Polish].