Occupational radiation exposures for medical workers in Pakistan – An overview

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The imperative use of ionizing radiation in medicine causes the inevitable occupational exposure of the medical workers during the course of routine duties. The magnitude of health risk due to such radiation exposures has been described in terms of occupational radiation doses. In this context, it is obligatory to monitor, measure and document the radiation dose of occupationally exposed medical workers. This study aims to review the whole-body occupational radiation exposures of medical workers in Pakistan. Specifically, online literature published during 2000-2018 was reviewed for the occupational radiation exposures of Pakistani medical workers. Analysis of the extracted personal dosimetry data revealed that the total number of monitored medical occupational workers was 26046. The range of total cumulative and annual average effective doses was 94-15785 Person-mSv and 0.66-7.37 mSv, respectively. A significant number of the workers (25477; ~98%) received an annual dose below 5 mSv, while only 18 workers received an occupational exposure exceeding the annual dose limit of 20 mSv. It is expected that this study will provide a useful reference for evaluating and improving radiation protection and safety policies in the country.
Rocznik
Strony
45--53
Opis fizyczny
Bibliogr. 60 poz., rys., tab.
Twórcy
autor
  • Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar, Pakistan
autor
  • Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar, Pakistan
  • Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar, Pakistan
  • Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar, Pakistan
  • Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar, Pakistan
autor
  • Department of Chemistry, Hazara University, Mansehra, Pakistan
Bibliografia
  • [1] Yuan T, Liang Z, Yongjian J. Dose level of occupational expo-sure in China. Radiat Prot Dosimetry. 2008;128(4):491-495.
  • [2] Jabeen A, Munir M, Khalil A, et al. Occupational exposure from external radiation used in medical practices in Pakistan by film badge dosimetry. Radiat Prot Dosimetry. 2010;140(4):396-401.
  • [3] Motevalli SM, Borhanazad AM. Assessment of occupational exposure in medical practice in Tehran, Iran. Rom Reports Phys. 015;67(2):431-438.
  • [4] Wakeford R. Radiation in the workplace—a review of studies of the risks of occupational exposure to ionising radiation. J Radiol Prot. 2009;29:A61–79.
  • [5] Ali NM. Evolution of Radiation Protection Trends – the Malaysian Perspective. Prog Nucl Sci Technol. 2011;1:14-19.
  • [6] Muhogora WE, Byorushengo E, Lema US, et al. Occupational radiation exposure in Tanzania (1996-2010): status and trends. Radiat Prot Dosimetry. 2012;153(4):403-410.
  • [7] Rahman MS, Begum A, Hoque A, et al. Assessment of whole-body occupational radiation exposures in nuclear medicine practices of Bangladesh during 2010-2014. Iran J Nucl Med. 2016;24(1):51-58.
  • [8] Rahman MS, Begum A, Hoque A, et al. Assessment of whole-body occupational radiation exposure in industrial radiography practices in Bangladesh during 2010-2014. Brazilian J Radiat Sci. 2016;4(2):1-17.
  • [9] Linet MS, Kim KP, Miller DL, et al. Historical review of occupational exposures and cancer risks in medical radiation workers. Radiat Res. 2010;174(6):793-808.
  • [10] Pakistan Nuclear Regulatory Authority (PNRA). Regulations on Radiation Protection (PAK/904). 2004.
  • [11] International Atomic Energy Agency (IAEA). International Basic Safety Standards for protection against ionizing radiation and for the safety of radiation sources, Safety Series No. 115. 1996.
  • [12] International Atomic Energy Agency (IAEA). Assessment of Occupational Exposure Due to External Sources of Radiation, Safety Guide No. RS-G-1.3. 1999.
  • [13] International Atomic Energy Agency (IAEA). Occupational Radiation Protection, Safety Guide No. RS-G-1.1. 1999.
  • [14] International Atomic Energy Agency (IAEA). Occupational Radiation Protection in the Mining and Processing of Raw Materials, Safety Standards Series No. RS-G-1.6. 2004.
  • [15] International Atomic Energy Agency (IAEA). Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards (GSR Part 3). 2014.
  • [16] International Commission on Radiological Protection (ICRP). 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 1991;21(1-3).
  • [17] International Commission on Radiological Protection (ICRP). The 2007 Recommendations of the International Commission on Radiological Protectiin: ICRP Publication 103. Ann ICRP. 2007;37:1-332.
  • [18] Khan SH, Ahmad SM. Whole Body Dose to Radiation Workers at a Tertiary Care Hospital in Kashmir: Analysis and Comparison with Naional Multi-Institutional Pool of Medical Radiation Workers. Indian J Nucl Med. 2003;18(3):57-61.
  • [19] Zeyrek CT, Gunduz H. Occupational exposure to ionizing radiation with thermoluminescence dosimetry system in Turkey, in 2003. Radiat Prot Dosimetry. 2005;113(4):374-380.
  • [20] Gunduz H, Zeyrek CT, Aksu L, Isak S. Occupational exposure to ionizing radiation in the region of Anatolia, Turkey for the period 1995-1999. Radiat Prot Dosimetry. 2004;108(4):293-301.
  • [21] Samerdokiene V, Atkocius V, Ofomala R. Radiation exposure recieved by the medical radiation workers in Lithuania at the institute of oncology, Vilnius university, 2004-2011. Radiat Prot Dosimetry. 2013;157(1):152-157.
  • [22] Valuckas KP, Atkocius V, Samerdokiene V. Occupational exposure of medical radiation workers in Lithuania, 1991–2003. Acta Medica Litu. 2007;14(3):155-159.
  • [23] Samerdokiene V, Atkocius V, Kurtinaitis J, Valuckas KP. Occupational exposure of medical radiation workers in Lithuania, 1950-2003. Radiat Prot Dosimetry. 2008;130(2):239-243.
  • [24] Park M, Kim G, Ji YH, et al. Trends of the effective dose distribution of occupational exposures in medical and research departments for KIRAMS in Republic of Korea. Radiat Prot Dosimetry. 2014;158(2):241-245.
  • [25] Korir GK, Wambani JS, Korir IK. Estimation of annual occupational effective doses from external ionising radiation at medical institutions in Kenya. SA J Radiol. 2011;15(4):116-119.
  • [26] Almasri HY, Kakinohana Y, Yogi T. Occupational radiation monitoring at a large medical center in Japan. Radiol Phys Technol. 2014;7(2):271-276.
  • [27] Colgan PA, Currivan L, Fenton D. An assessment of annual whole-body occupational radiation exposure in Ireland (1996-2005). Radiat Prot Dosimetry. 2008;128(1):12-20.
  • [28] Kamenopoulou V, Drikos G, Dimitriou P. Occupational exposure to ionizing radiation in Greece (1994-1998). Radiat Prot Dosimetry. 2000;91(4):385-389.
  • [29] Hasford F, Owusu-Banahen J, Amoako JK, et al. Assessment of annual whole-body occupational radiation exposure in medical practice in Ghana (2000-09). Radiat Prot Dosimetry. 2012;149(4):431-437.
  • [30] Alramlawi SA, Alsaqr AS, Zayat DMA, Galal M. Assessing the occupational radiation doses for medical workers at Cairo university hospital based on job categories. Arab J Nucl Sci Appl. 2015;48(1):40-43.
  • [31] Weizhang W, Wenyi Z, Ronglin C, Liang’an Z. Occupational exposures of Chinese medical radiation workers in 1986 – 2000. Radiat Prot Dosimetry. 2005;117(4):440-443.
  • [32] Behroozi H. Occupational exposure and mistakes in the wearing of film badges in computed tomography staff (1990-2009). Radiography. 2014;20(1):33-35.
  • [33] Basić B, Beganović A, Samek D, et al. Ten years of monitoring the occupational radiation exposure in Bosnia and Herzegovina. Radiat Prot Dosimetry. 2010;139(1):400-402.
  • [34] Banu H, Alam MN, Chowdhury MI, et al. Assessment of occupational and patient dose from diagnostic and therapeutic radiation exposure using thermoluminescent dosimetry. Health Phys. 1998;74(4):478-480.
  • [35] UNSCEAR. Sources and Effects of Ionizing Radiation, United Nations Scientific Committee on the Effects of Atomic Radiation UNSCEAR 2000 Report to the General Assembly, with Scientific Annexes [Internet]. Vol. I. 2000. 1-17 p. Available from: http://www.unscear.org/docs/publications/2000/UNSCEAR_2000_Report_Vol.I.pdf
  • [36] The pakistan atomic energy commission ordinance, 1965. Gazette of Pakistan, No: XVII of 1965.
  • [37] Hussain M, Khan RA, Nasim B. Regulatory Framework for Occupational Exposure Management in Pakistan. 2009;1-5. Available from: http://www.isoe-network.net/publications/pub-proceedings/symposia/international-symposia/vienna-austria-october-2009/papers-5/session-4-occupational-exposure-in-npps-1/1304-nasim2009-pdf/file.html
  • [38] Fazal-e-Rahim, Shah AS, Rahim I. Trends in occupational radiation exposures at IRNUM (2000-2008). Pakistan J Radiol. 2011;21(2):59-62.
  • [39] Masood K, Ahmad M, Zafar J, et alH. Assessment of occupational exposure among Pakistani medical staff during 2007-2011. Australas Phys Eng Sci Med. 2012;35(3):297-300.
  • [40] Memon SA, Laghari NA, Cheema AA. Evaluation of radiation workers’ occupational doses working at NIMRA Jamshoro. J Liaquat Univ Med Heal Sci. 2012;11(3):190-194.
  • [41] Zafar T, Masood K, Zafar J. Assessment of personal occupational radiation exposures received by nuclear medicine and oncology staff in Punjab (2003–2012). Australas Phys Eng Sci Med. 2015;38(3):473-478.
  • [42] Younas S, Yar A, Qadir E, Nawaz K. Radiation dose management of 18FDG for occupational workers and comforters. Pakistan J Nucl Med. 2015;5(1):58-66.
  • [43] Gadhi MA, Fatmi S, Gadhi MS, et al. Variation of annual effective dose from external ionizing radiation among radiation workers of Bahawalpur Institute of Nuclear Medicine and Oncology (BINO). Pakistan. Int J Radiat Res. 2016;14(3):229-235.
  • [44] Razaq A, Waqar M, Soomro Q, Javed MA. Evaluation of radiation workers occupational doses for newly established medical center NORIN Nawabshah in Pakistan. J Med Phys Biophys. 2016;3(1):61-65.
  • [45] Ahmad M, Ahmad H, Khattak MR, et al. Assessment of Occupational Exposure From External Radiation to Workers at IRNUM, Pakistan (2009-2016). Iran J Med Phys. 2017;14(4):197-202.
  • [46] Carreiro JV, Avelar R. Occupational exposure in medical and paramedical professions in Portugal. Radiat Prot Dosimetry. 1991;36(2):233-236.
  • [47] Koczynski A, Chec A, Lach D, Dabek M. Occupational exposure to external ionizing radiation in Poland, 1999. Radiat Prot Dosimetry. 2001;96(1-3):61-62.
  • [48] El-din MME, Mahmoud RMM, Abaza A, et al. Occupational Radiation Exposure in Pet/Ct Units. Arab J Nucl Sci Appl. 2017;50(3):58-65.
  • [49] Seierstad T, Stranden E, Bjering K, et al. Doses to nuclear technicians in a dedicated PET/CT centre utilising 18F flurodeoxyglucose (FDG). Radiat Prot Dosimetry. 2007;123(2):246-249.
  • [50] Roberts FO, Gunawardana DH, Pathmaraj K, et al. Radiation Dose to PET Technologists and Strategies to Lower Occupational Exposure. J Nucl Med Technol. 2005;33(1):44-47.
  • [51] Antic V, Ciraj-Bjelac O, Stankovic J, et al. Radiation exposure to nuclear medicine staff involved in PET/CT practice in Serbia. Radiat Prot Dosimetry. 2014;162(4):577-585.
  • [52] Castrillo SV, Henriquez FC. A study on occupational exposure in a PET/CT facility. Radiat Prot Dosimetry. 2011;147(1):247-249.
  • [53] Dalianis K, Kollias G, Malamitsi J, et al. Doses to medical workers operating in a PET/CT department after the use of new dynamic techniques. J Phys Conf Ser. 2015;637(1):12003.
  • [54] Demir M, Demir B, Yaşar D, et al. Radiation doses to technologists working with 18 F-FDG in a PET center with high patient capacity. Nukleonika. 2010;55(1):107-112.
  • [55] Cronin B, Marsden PK, Doherty MJO. Are restrictions to behaviour of patients required following fluorine-18 fluorodeoxyglucose positron emission tomographic studies ? Eur J Nucl Med. 1999;26(2):121-128.
  • [56] Biran T, Weininger J, Malchi S, et al. Measurement of occupational exposure for 18F FDG PET scans. Health Phys. 2004;87(5):539-544.
  • [57] Zeff BW, Yester M V. Patient self-attenuation and technologist dose in positron emission tomography. Med Phys. 2005;32(4):861-865.
  • [58] Benator NA, Cronin BF, O’Doherty MJ. Radiation dose rates from patients undergoing PET: Implications for technologists and waiting areas. Eur J Nucl Med. 2000;27(5):583-589.
  • [59] Chiesa C, Sanctis V De, Crippa F, et al. Radiation dose to technicians per nuclear medicine procedure : comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose. Eur J Nucl Med. 1997;24(11):1380-1389.
  • [60] UNSCEAR. Sources and Effects of Ionizing Radiation, United Nations Scientific Committee on the Effects of Atomic Radiation UNSCEAR 2008 Report to the General Assembly, with Scientific Annexes. Vol. I. 2008. 1-683 p.
Uwagi