Respiratory Disorders - Measuring Method and Equipment

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Respiratory disorders can occur from birth and accompany us throughout life. Very relevant and timely diagnosis of dysfunction is very important. Many currently performed examinations are not sufficient and do not give a full view of the cause of the disorder. In this paper the authors give several methods and pieces of equipment to do so. Furthermore, the proposed solution enables precise quantification of individual breaths, as well as their entire series. In addition to the above mentioned equipment, the authors present an example of software that works with the adopted solution. The considerations are illustrated with an example, along with calculations made using the authors’ software.
Rocznik
Strony
187--202
Opis fizyczny
Bibliogr. 25 poz., rys.
Twórcy
  • University of Warmia and Mazury in Olsztyn, Faculty of Technical Sciences, Słoneczna 46a, 10-710 Olsztyn, Poland
  • Faculty of Medical Sciences, Department of Neurology and Neurosurgery, Warszawska 30, 10-082 Olsztyn, Poland
autor
  • AGH University of Science and Technology, Faculty of Mechanical Engineering and Robotics, Al. A. Mickiewicza 30, 30-059 Cracow, Poland
autor
  • University of Warmia and Mazury in Olsztyn, Faculty of Medical Sciences, Warszawska 30, 10-082 Olsztyn, Poland
autor
  • Military University of Technology, Institute of Optoelectronics, S. Kaliskiego 2, 00-908 Warsaw, Poland
Bibliografia
  • [1] Kornacka, M. K., Tołłoczko, J. (2010). Respiratory disorders in the near term newborns. Pediatria i Medycyna Rodzinna, 6(4), 287-290.
  • [2] Gadzinowski, J., Hnatyszyn, G., Kęsiak, M., Szczapa, J. (2010). Podstawy neonatologii. Warszawa: Wydawnictwo Lekarskie PZWL.
  • [3] Kuźmińska, M., Walicka, M., Sawicka, A., Kukwa, W., Marcinowska-Suchowierska, E. (2016). Average and minimum oxygen saturation in patients with suspected OSA as a disease severity index in polysomnographic evaluation. Postępy Nauk Medycznych, 1, 64-70.
  • [4] Mikołajczyk, J., Wojtas, J., Bielecki, Z., et al. (2016). System of Optoelectronic Sensors for Breath Analysis. Metrol. Meas. Syst., 23(3), 481-489.
  • [5] Mikołajczyk, J., Bielecki, Z., Stacewicz, T., et al. (2016). Detection of Gaseous Compounds with Different Techniques. Metrol. Meas. Syst., 23(2), 205-224.
  • [6] Stacewicz, T., Bielecki, Z., Wojtas, J., et al. (2016). Detection of disease markers in human breath with laser absorption spectroscopy. Opto-Electronics Review, 24(2), 82-94.
  • [7] Hutchinson, J. (1846). On the capacity of the lungs and on the respiratory movements with the view of establishing a precise and easy method of detecting disease by the spirometer. Lancet, 1, 630-632.
  • [8] Deberry-Borowiecki, B., Kukwa, A., Blanks, R.H.I. (1988). Cephalometric analysis for diagnosis and treatment of obstructive sleep apnea. The Laryngoscope, 98, 226-234.
  • [9] Kukwa, A. Sleep Disorders - sleep apnea syndrome.
  • [10] Lyons, R.G. (2010). Understanding Digital Signal Processing. Wprowadzenie do cyfrowego przetwarzania sygnałów. Warszawa: WKŁ.
  • [11] Nawrocki, W. (2006). Sensory i systemy pomiarowe . Poznań: Wydawnictwo Politechniki Poznańskiej.
  • [12] Durst, F., Melling, A., Whitelaw, J.H. (1976). Principles and practice of laser-Doppler anemometry. London, New York: Academic Press.
  • [13] Piotrowski, J. (2009). Pomiary, czujniki i metody pomiarowe wybranych wielkości fizycznych i składu chemicznego. Warszawa: WNT.
  • [14] Sydenham, P.H. Handbook of Measurement Science . Chichester: John Wiley.
  • [15] Eguti, C.C.A., Vieira, E.D.R. (2004). Development of a Basic Circuit of a Hot-Wire Anemometer. Proc. of the 10o Brazilian Congress of Thermal Sciences and Engineering - ENCIT.
  • [16] Specifications NI DAQ USB-6002, http://www.ni.com/pdf/manuals/374371a.pdf (Jan. 2017)
  • [17] Jamróz, P. (2016). Prototyp systemu do monitorowania oddechu. Wzorcowanie i użytkowanie. Instytut Mechaniki Górotworu PAN, Kraków.
  • [18] Elsner, J.W. (1987). Turbulencja przepływów. Warszawa: PWN.
  • [19] Elsner, J.W., Drobniak, S. (1989). Metrologia przepływów turbulentnych. Ossolineum.
  • [20] The NI TDMS File Format. http://www.ni.com/white-paper/3727/en/ (Jan. 2017).
  • [21] https://www.health.ny.gov/professionals/ems/pdf/assmttools.pdf (Jan. 2017).
  • [22] Beardsell I., Hubert D., Robinson S., Bell S., Rumbold H. (2009). MCEM Part A: MCQs, p. 33, Royal Society of Medicine Pr Ltd, London.
  • [23] Tomalak, W., et al. (2004). Zalecenia polskiego towarzystwa ftyzjopneumonologicznego dotyczące wykonywania badań spirometrycznych. IGiChP Oddział w Rabce.
  • [24] Eaton, T., Withy, S., Garret, J.F., et. al. (1999). Spirometry in primary care practice. The importance of quality assurance and the impact of spirometry workshops. Chest, 116, 416-423.
  • [25] Siergiejko, Z., Siergiejko, G., Siergiejko, D., Siergiejko, P., Świebocka, E. (2013). Spirometria - samodzielne poprawne wykonanie badania. Alergia, 3, 49-56.
Uwagi
EN
This project was supported by the University of Warmia nad Mazury in Olsztyn (No. 16.610.001-300, No. 25.610.001-300) and the research council of Poland, No. 11.11.130.955.
PL
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-c2b48362-0285-4bab-b030-3a7ab61ea949
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.