PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Lightning Induced Ventricular Fibrillation risk during wandering

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Ryzyko fibrylacji komór serca turystów pieszych wywołane wyładowaniem piorunowym
Języki publikacji
EN
Abstrakty
EN
Wandering is a popular way of spending leisure time especially for the urban population. Health problems arising from such outdoor recreational activities are better understood today and may improve survival in case of accidents if sufficient awareness of clinical staff is established. The purpose of this paper is to shed light on this physiological phenomenon by investigating the connection between the physics associated with lightning strikes and the physiological response of the human body. From the results a minimum safety-distance from different trees species is derived. Flat rooted trees are more dangerous than tap rooted trees. In the worst case it may be considered safe if a distance of at least 25 meters to tree trunks is maintained.
PL
Turystyka piesza jest popularnym sposobem spędzania wolnego czasu, szczególnie dla mieszkańców miast. Problemy zdrowotne wynikające z tej aktywności są dobrze poznane, ale w szczególnych przypadkach wiedza o zagrożeniu może być pomocna i może się przyczynić do zwiększenia szans na przeżycie. Celem tej publikacji jest pokazanie związku pomiędzy wyładowaniem piorunowym a reakcją organizmu ludzkiego. Na podstawie otrzymanych wyników wyznaczono bezpieczny odstęp od drzew podczas wyładowań piorunowych. Drzewa z systemem poziomym systemem korzeniowym stwarzają większe zagrożenie niż drzewa z systemem palowym. W najgorszym przypadku bezpieczny odstęp od pnia drzewa wynosić powinien co najmniej 25 metrów.
Rocznik
Strony
106--111
Opis fizyczny
Bibliogr. 39 poz., rys., tab., wykr.
Twórcy
autor
  • Białystok Technical University, Department of Telecommunications and Electronic Equipment, ul. Wiejska 45d, 15-351 Białystok, Poland
Bibliografia
  • [1] NLSI International Lightning Safety Initiative. 2014. http://www.lightningsafety.com/nlsi_history/intl_safety_initiative.html
  • [2] Ronald L Holle. Activities and locations of recreation deaths and injuries from lightning. Royal Aeronautical Society 2003. http://www.lightning-strike.org/Portals/20a4c8c2-6f09-4d50-a98a-08365ce9e232/library/103-77KMI-Holle.pdf
  • [3] NWS Lightning Safety Outdoors. http://www.lightningsafety.noaa.gov/outdoors.htm
  • [4] John Gookin. NOLS Backcountry Lightning Safety Guidelines. http://rendezvous.nols.edu/files/Curriculum/research_projects/Risk%20Management%20Reports/NOLS%20Backcountry%20Lightning%20Safety%20Guidelines.pdf
  • [5] Deborah R. Levy, Toshio Akiyama. Lightning-induced ventricular fibrillation. Cardiology Journal 2007, Vol. 14, No.1, pp. 91-95
  • [6] Dronacharya L, Poudel R. Lightning induced atrial fibrillation. Kathmandu University Medical Journal (2008), Vol. 6, No. 4, Issue 24, pp. 514-515
  • [7] Lichtenberg R, Dries D. Cardiovascular Effects of Lightning Strikes. JACC Vol. 21, No.2, February 1993, pp. 531-6
  • [8] Karadas S,Vurusjan E, Dursun R, Sincer I, Gonullu H, Akkaya E. Myocardial infarction due lightning strike. JPMA September 2013, pp. 1186-8
  • [9] Pfortmueller CA, Yikun Y, Haberkern M, Wuest E, Zimmermann H, Exadaktylos AK. Injuries, sequelae, and treatment of lightning induced injuries: 10 years of experience at a Swiss trauma center. Emerg Med Int 2012; 2012: Article ID167698. doi:10.1155/2012/167698
  • [10] Cooper MA. A fifth mechanism of lightning injury. Acad Emerg Med 2002; 9: 172-4
  • [11] Cooper MA, Holle RL, Andrews C. Distribution of lightning injury mechanisms. 20th International Lightning Detection Conference 2008.
  • [12] Cooray V. Lightning Protection. Institution of Engineering and Technology 2010.
  • [13] Uman MA. The Art and Science of Lightning Protection. Cambridge University Press 2008.
  • [14] DEHN + SÖHNE. Lightning Protection Guide. Neumarkt Germany 2007.
  • [15] IEC 61312-1:1995. Protection against lightning electromagnetic impulse - Part 1: General principles.
  • [16] IEC 62305-1:Ed2:2010-12. Protection against lightning – Part 1: General principles.
  • [17] Thomson EM. The dependence of lightning return stroke characteristics on latitude. Journal of Geophysical Research, 1980, 85:1050-56.
  • [18] Heidler F, Hopf C. Measurement results of the electric fields in cloud-to-ground lightning in nearby Munich, Germany. IEEE Transactions on Electromagnetic Compatibility 1998;40(4):436-43.
  • [19] Thottappillil R, Rakov VA, Uman MA, Beasley WH, Master MJ, Shelukhin DV. Lightning subsequent-stroke electric field peak greater than the first stroke peak and multiple ground teminations. Journal of Geophysical Research, 992;97(D7):7503-509.
  • [20] Cooray V, Perez H. Some features of lightning flashes observed in Sweden. Journal of Geophysical Research, 1994;99(D5): 10683-88.
  • [21] Cooray V, Jayaratne KP. Characteristics of lightning flashes observed in Sri Lanka in the tropics. Journal of Geophysical Research, 1994;99(D10): 21051-65.
  • [22] Rakov V.A., Uman M.A., Thottappillil R. Review of lightning properties from electric field and TV observations. Journal of Geophysical Research, 1994;99:10745-50.
  • [23] Qie Xiushu, Ye Yu, Daohong Wang, Huibin Wang, Rongzhong Chu. Characteristics of cloud-to-ground lightning in Chinese Inland Plateau notes and correspondence. Journal of the Meteorological Society of Japan, 2002;80(4):745-54.
  • [24] Miranda FJ, de Pinto OJr, Saba MMF. A study of the time interval between return strokes and K-changes of negative cloud-to-ground lightning flashes in Brazil. Journal of Atmospheric and Solar-Terrestrial Physics, 2003;65:293-97.
  • [25] Saba MMF, Ballarotti MG, Pinto OJr. Negative cloud-toground lightning properties from high-speed video observations. Journal of Geophysical Research, 2006;111:D03101.
  • [26] Zafren K, Durrer B, Herry JP, Brugger H. Lightning injuries: prevention and on-site treatment in mountains and remote ares. Resuscitation 65 (2005), pp. 369-372.
  • [27] IEEE Std 80-2002: IEEE Guide for Safety in AC Substation Grounding.
  • [28] Gale MR, Grigal DF. Vertical root distributions of northern tree species in relation to successional status. Canadian Journal of Forest Research, 1987, 17(8): 829-834, 10.1139/x87-131.
  • [29] Sowa A.W.: Ochrona urządzeń oraz systemów elektronicznych przed narażeniami piorunowymi. Rozprawy Naukowe Nr 219. Oficyna Wydawnicza Politechniki Białostockiej, Białystok 2011, Poland.
  • [30] IEC 60364. Electrical Installations for Buildings
  • [31] IEC 61000-4-2 ed2. Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test.
  • [32] IEC/TS 60479-2 ed3. Effects of current on human beings and livestock - Part 2: Special aspects.
  • [33] Neuhaus H: Blitzschutzanlagen: Erlauterungen zu DIN 57 185/VDE 0185. 1. Aufl. Berlin; Offenbach: VDE-Verlag, 1983.
  • [34] Dalziel A., Charles F., Lee W.R.: Reevaluation of Lethal Electric Currents. In: IEEE Tran. Ind. Gen. Apple IGA-4 (1968), Nr. 5; pp. 467-476.
  • [35] http://www.nlm.nih.gov/research/visible/visible_human.html The National Library of Medicine's Visible Human Project.
  • [36] Flisowski Z.: Trendy rozwojowe ochrony odgromowej budowli. Część I. Wyładowania piorunowe jako źródło zagrożenia. PWN, Warszawa 1986, Poland.
  • [37] CDEGS Current Distribution, Electromagnetic Interference, Grounding and Soil Structure Analysis. Safe Engineering Services & Technologies Ltd., Montreal Canada.
  • [38] IEC 62305-3:2005, Protection against lightning – Part 3. Physical damage to structure and life hazard.
  • [39] http://commons.wikimedia.org/wiki/File:EKG_Complex_en.svg#mediaviewer/File:EKG_Complex_en.svg
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-c127cd13-1cce-44ab-9380-7d0149efa6a6
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.