PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Technological reliability of sewage treatment plant with the Pomiltek Mann type bioreactor

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The aim of the work was to determine the technological reliability of the selected pollution indicators removal BOD5, CODCr and total suspension from the sewage treatment plant working with the bioreactor Pomiltek Mann type. Wastewater treatment plant which is a subject of this study is located in Lesser Poland, in Siepraw commune. The analysis was performed using the Weibull method for basic indicators of impurities, BOD5, CODCr and total suspended solids. Physico-chemical analyses of raw and treated wastewater, were carried out in the period from 2003 to 2014 (11 years). The research period included measured values of pollutions indicators in 38 samples of raw and treated sewage. For each of pollution indicators descriptive statistic, percentage reduction (n) and treatment plant reliability factors (RF) were calculated. Average reduction for BOD5 and TSS was on level equal 94%, only for COD the average reduction was lower and was on level 89%. The reliability values determined by Weibull method, were: 75% (BOD5), 90% (CODCr) and 89.5% (TSS). The reliability results have been lower than the presented by literature source, which means that work of wastewater treatment plant in Siepraw was not satisfied in 11 years of research.
Wydawca
Rocznik
Tom
Strony
146--152
Opis fizyczny
Bibliogr. 34 poz., rys., tab.
Twórcy
  • University of Agriculture in Krakow, Faculty of Environmental Engineering and Land Surveying, Department of Sanitary Engineering and Water Management, al. Mickiewicza 21, 31-120 Krakow, Poland
  • University of Agriculture in Krakow, Faculty of Environmental Engineering and Land Surveying, Department of Sanitary Engineering and Water Management, al. Mickiewicza 21, 31-120 Krakow, Poland
  • University of Agriculture in Krakow, Faculty of Environmental Engineering and Land Surveying, Department of Sanitary Engineering and Water Management, al. Mickiewicza 21, 31-120 Krakow, Poland
  • University of Agriculture in Krakow, Faculty of Environmental Engineering and Land Surveying, Department of Sanitary Engineering and Water Management, al. Mickiewicza 21, 31-120 Krakow, Poland
  • University of Agriculture in Krakow, Faculty of Environmental Engineering and Land Surveying, Department of Sanitary Engineering and Water Management, al. Mickiewicza 21, 31-120 Krakow, Poland
Bibliografia
  • ANDRAKA D., DZIENIS L. 2003. Wymagany poziom niezawodności oczyszczalni ścieków w świetle przepisów polskich i europejskich [Required reliability level of wastewater treatment plants according to European and Polish regulations]. Zeszyty Naukowe Politechniki Białostockiej. Ser. Inżynieria Środowi-ska. Z. 16 p. 24–28.
  • BARTON L.E., AUFFAN M., DURENKAMP M., MCGRATH S., BOTTERO J., WIESNER M.R. 2015. Monte Carlo simulations of the transformation and removal of Ag, TiO2, and ZnO nanoparticles in wastewater treatment and land application of biosolids. Science of the Total Environment. Vol. 511 p. 535–543. DOI 10.1016/j.scitotenv.2014.12.056.
  • BŁAŻEJEWSKI R. 2003. Kanalizacja wsi. Poznań. PZITS Oddział Wielkopolski. ISBN 83-914252-3-1 pp. 351.
  • BUGAJSKI P. 2014. Analiza niezawodności funkcjonowania oczyszczalni bioblok ps-50 z zastosowaniem metody Weibulla [Analysis of reliability of the treatment plant bioblok ps-50 using the method of Weibull]. Infrastruktura i Ekologia Terenów Wiejskich. Z. II/3 p. 667–677. DOI 10.14597/ infraeco.2014.2.3.049.
  • BUGAJSKI P., ALMEIDA M.A.A., KUREK K. 2016. Reliability of sewage treatment plants processing sewage from school buildings located in non-urban areas. Infrastruktura i Ekologia Terenów Wiejskich. Z. IV/3 p. 1547–1557. DOI 10.14597/infraeco.2016.4.3.115.
  • BUGAJSKI P., BERGEL T., KACZOR G. 2015. Niezawodność usuwania azotu ze ścieków w zbiorczej oczyszczalni z sekwencyjnym reaktorem biologicznym [The removal of reliability nitrogen in wastewater treatment plant with sequencing biological reactor]. Acta Scientiarum Polonorum. Formatio Circumiectus. Vol. 14. Iss. 3 p. 19–27. DOI 10.15576/ASP. FC/2015.14.3.19.
  • BUGAJSKI P., KACZOR G. 2008. Ocena działania wybranych przydomowych oczyszczalni w warunkach zimowych i letnich [Reliability and stability of sewage treatment plants work with use of statistical quality control]. Przemysł Chemiczny. Vol. 5 p. 424–426.
  • BUGAJSKI P., MIELENZ B. 2008. Ocena pracy oczyszczalni ścieków w Wadowicach przed modernizacją [The assessment of working sewage treatment plant at Wadowice before the modernization]. Infrastruktura i Ekologia Terenów Wiejskich. Z. 2 p. 129–138.
  • BUGAJSKI P., WAŁĘGA A. 2010. Ocena niezawodności działania przydomowej oczyszczalni ścieków [Reliability assessment of the household sewage treatemnt plant]. Infrastruktura i Ekologia Terenów Wiejskich. Z. 2 p. 45–53.
  • CHMIELOWSKI K., RAJCHEL B., KARNAS M. 2016. Analiza skuteczności działania oczyszczalni ścieków „Kujawy” [Analysis of operation effectivness of the „Kujawy” sewage treatment plant]. Czasopismo Inżynierii Lądowej, Środowiska i Architektury. No. 2(I16) p. 31–42. DOI 10.7862/rb.2016.107.
  • CHMIELOWSKI K., SATORA S., WAŁĘGA A. 2009. Ocena niezawodności działania oczyszczalni ścieków dla gminy Tuchów [Evaluation of the reliability of the sewage treatment plant for the commune of Tuchów]. Infrastruktura i Ekologia Terenów Wiejskich. Z. 9 p. 63–72.
  • GÓRKA J. 2015. Ocena stabilności procesu oczyszczania ścieków za pomocą kart kontrolnych [Rating of stability of wastewater treatemnt proces by using control cards]. Nauki Inżynierskie i Technologie. Vol. 3. Iss. 18 p. 9–16. DOI 10.15611/nit. 2015.3.01.
  • Gmina Siepraw undated [Siepraw Commune] [online]. [Access 10.11.2019]. Available at: http://www.siepraw.pl/
  • HEIDRICH Z., WITKOWSKI A. 2005. Urządzenia do oczyszczania ścieków. Warszawa. Wydaw. Seidel-Przywecki. ISSN 2080-5985 pp. 315.
  • JÓŹWIAKOWSKI K., BUGAJSKI P., KUREK K., CARVALHO F., ALMEIDA A., SIWIEC T., BOROWSKI G., CZEKAŁA W., DACH J., GAJEWSKA M. 2018. The efficiency and technological reliability of biogenic compounds removal during long-term operation of a one-stage subsurface horizontal flow constructed wetland. Separation and Purification Technology. Vol. 202 p. 216–226. DOI 10.1016/j.seppur.2018.03.058.
  • JÓŹWIAKOWSKI K., BUGAJSKI P., MUCHA Z., WÓJCIK W., JUCHER-SKI A., NASTAWNY M., SIWIEC T., MAZUR A., OBROŚLAK R., GAJEWSKA M. 2017. Reliability and efficiency of pollution removal during long-term operation of a one-stage constructed wetland system with horizontal flow. Separation and Purification Technology. Vol. 187 p. 60–66. DOI 10.1016/ j.seppur.2017.06.043.
  • JUCHERSKI A., WALCZOWSKI A., BUGAJSKI P., JÓŹWIAKOWSKI K. 2019. Technological reliability of domestic wastewater purification in a small Sequencing Batch Biofilm Reactor (SBBR). Separation and Purification Technology. Vol. 224 p. 340–347. DOI 10.1016/j.seppur.2019.05.024.
  • KACZOR G. 2009. Stężenie zanieczyszczeń w ściekach odprowadzanych z wiejskich systemów kanalizacyjnych województwa małopolskiego [Concentration of the pollutants in the sewage drained from the rural sewage system in lesser Poland voivodeship]. Infrastruktura i Ekologia Terenów Wiejskich. Z. 9 p. 97–104.
  • KACZOR G., BUGAJSKI P. 2007. Ocena pracy oczyszczalni ścieków typu Ecolo-Chief w Spytkowicach [The assessment of working ecolo-chef sewage treatment plant at Spytkowice]. Infrastruktura i Ekologia Terenów Wiejskich. Z. 1 p. 187–195.
  • KRZANOWSKI S., WAŁĘGA A. 2006. Wykorzystanie teorii niezawodności i statystycznej kontroli jakości do oceny eksploatacyjnej wiejskich oczyszczalnie ścieków [Utilization of the reliability theory and statistical quality control to assess the operation of rural sewage treatment plants]. Infrastruktura i Ekologia Terenów Wiejskich. Z. 3 (2) p. 17–37.
  • MARZEC M. 2017. Reliability of removal of selected pollutants in different technological solutions of household wastewater treatment plant. Journal of Water and Land Development. No. 35 p. 141–148. DOI 10.1515/jwld-2017-0078.
  • MIERNIK W., MŁYŃSKI D. 2014. Analiza efektywności pracy oczyszczalni ścieków w Krzeszowicach po modernizacji [Analysis of the efficency of sewage treatment plant in Krzeszowice after its modernization]. Episteme. Vol. 2 p. 303–310.
  • MIERNIK W., WAŁĘGA A. 2006. Wpływ czasu eksploatacji na efekty oczyszczania ścieków w oczyszczalni typu Lemna [Influence of operation time the efficiency of on effectiveness at sewage treatment process in Lemna sewage treatment plant]. Infrastruktura i Ekologia Terenów Wiejskich. No 3/2 p. 39–51.
  • MIKSCH K., SIKORA J. 2010. Biotechnologia ścieków [Waste biotechnology]. Warszawa. Wydaw. Nauk. PWN. ISBN 978-83-01-16183-5 pp. 238.
  • MŁYŃSKA A., CHMIELOWSKI K., MŁYŃSKI D. 2017. Analiza zmian jakości ścieków w trakcie procesów oczyszczania na oczyszczalni w Przemyślu [The analysis of the changes in the sewage quality during treatment processes on the wastwater treatment plant in Przemyśl]. Inżynieria Ekologiczna. Vol. 18 (5) p. 18–26.
  • MŁYŃSKI D., BUGAJSKI P., MŁYŃSKA A. 2019. Application of the mathematical simulation methods for the assessment of the wastewater treatment plant operation work reliability. Water. No. 11(11) p. 1-17. DOI 10.3390/w11050873.
  • MŁYŃSKI D., CHMIELOWSKI K., MŁYŃSKA A., MIERNIK W. 2016. Ocena skuteczności pracy oczyszczalni ścieków w Jaśle [Evaluation of efficience of sewage treatment plant in Jasło]. Infrastruktura i Ekologia Terenów Wiejskich. Z. I/1 p. 147–162.
  • MUCHA J. 1999. Metody geostatystyczne w dokumentowaniu złóż. Skrypt. AGH pp. 157.
  • PAWEŁEK J., BUGAJSKI P. 2017. Rozwój przydomowych oczyszczalni ścieków w Polsce – zalety i wady rozwiązań [The development of household wastewater treatment plant in Poland – adventages and disadventages]. Acta Scientiarum Polonorum. Formatio Circumiectus. Vol. 16(2) p. 3–14.
  • PIASECKI A. 2019. Water and Sewage management issues in rural Poland. Water. Vol. 11(3) p. 1–16. DOI 10.3390/w1103062.
  • Rozporządzenie Ministra Środowiska z dnia 18 listopada 2014 r. w sprawie warunków, jakie należy spełnić przy wprowadzaniu ścieków do wód lub do ziemi, oraz w sprawie substancji szczególnie szkodliwych dla środowiska wodnego [Order of the Minister of Environment of 18 November 2014 on conditions to be met when introducing of sewage into the water or ground and on substances particulary harmful to the aquatic environment]. Dz.U. 2014 poz. 1800.
  • SUBRAMANI T., MANGAIYARKARAS M., KATHIRVEL C. 2014. Impact of sewage and industrial effluent on soil plant health act on environment. Journal of Engineering Research and Applications. Vol. 4. Iss. 6 p. 270–273.
  • WAŁĘGA A., CHMIELOWSKI K., MŁYŃSKI D. 2018. Influence of the hybrid sewage treatment plant’s exploitation on its operation effectiveness in rural areas. Sustainability. Vol. 10, 2689. DOI 10.3390/su10082689.
  • WIERZBICKI K. 2006. Wybrane problemy kanalizacji na obszarach wiejskich [Selected issues concerning sewage systems of rural areas]. Instal. Vol. 2 p. 52–56.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2020).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-c0c0046b-0996-4df6-b080-dad56a66e4fc
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.