System for monitoring the process continuity of the intravenous infusion – development study

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
System monitorowania ciągłości procesu infuzji dożylnej – studium rozwojowe
Języki publikacji
EN
Abstrakty
EN
The paper presents Authors’ development of the concept of a monitoring system for the low level infusion fluid detection. The results presented previously in [1], were achieved for a system based on the scale and weight of the fluid bottle. As this method suffers from i.e. subject’s movements Authors decided to investigate also other methods with the optical one as first. Also network communication was introduced. It can be involved in the hospital care procedures undertaken during subjects’ treatments.
PL
W artykule przedstawiono Autorską koncepcję systemu do monitorowania i detekcji niskiego poziomu płynu infuzyjnego. Wyniki przedstawione wcześniej w [1] zostały uzyskane dla systemu opartego na wadze z butelką z płynem. Ponieważ metoda ta jest wrażliwa m.in. na ruchy pacjenta, Autorzy postanowili zbadać również inne metody, np.: metodę optyczną. W układzie wykorzystano również. komunikację sieciową, która może posłużyć do budowy systemu rozproszonego na użytek procedur opieki szpitalnej podejmowane podczas leczenia.
Rocznik
Strony
261--264
Opis fizyczny
Bibliogr. 7 poz., rys.
Twórcy
autor
  • Warsaw University of Technology, Faculty of Electrical Engineering
  • Medical University of Warsaw, II Department of Anaesthesiology and Intensive Care
  • Warsaw University of Technology, Faculty of Electrical Engineering
autor
  • Warsaw University of Technology, Faculty of Electrical Engineering
  • Warsaw University of Technology, Faculty of Electrical Engineering
  • Warsaw University of Technology, Faculty of Electrical Engineering
Bibliografia
  • [1] A. Jóśko, W. Romanik, “System for the support of the intravenous infusion process continuity”, Przeglad Elektrotechniczny 2023.06, doi: 10.15199 / 48.2023.06.18.
  • [2] A. Cataldo, G. Cannazza, N. Giaquinto, A. Trotta and G. Andria, "Development of a remote system for real-time control of intravenous drip infusions," 2011 IEEE International Symposium on Medical Measurements and Applications, 2011, pp. 234-237, doi: 10.1109/MeMeA.2011.5966738.
  • [3] C. Jianwen and Z. Han, "Design of intravenous infusion monitoring and alarm system based on wireless communication technology," 2011 IEEE International Conference on Mechatronics and Automation, 2011, pp. 130-134, doi: 10.1109/ICMA.2011.5985644.
  • [4] H. Ogawa, H. Maki, S. Tsukamoto, Y. Yonezawa, H. Amano and W. M. Caldwell, "A new drip infusion solution monitoring system with a free-flow detection function," 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 2010, pp. 1214-1217, doi: 10.1109/IEMBS.2010.5626449.
  • [5] https://www.arduino.cc/
  • [6] HX711 24-Bit Analog-to-Digital Converter (ADC) for Weight Scales.
  • [7] https://www.espressif.com/en/products/socs/esp8266.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa nr POPUL/SP/0154/2024/02 w ramach programu "Społeczna odpowiedzialność nauki II" - moduł: Popularyzacja nauki i promocja sportu (2025).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-bf359d21-b6f1-4def-b387-52b72dd08b79
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.