Powiadomienia systemowe
- Sesja wygasła!
- Sesja wygasła!
Tytuł artykułu
Autorzy
Treść / Zawartość
Pełne teksty:
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
The objective of the study was to describe and compare the acute response of muscle oxygen saturation (SmO2) and hemoglobin concentration (Hgb) in the vastus lateralis (VL) during resistance exercise protocols until failure. Methods: Sixteen males were considered (mean ± SD, age = 36.12 ± 6.40 years). Two familiarization sessions and one evaluation session were carried out where three force protocols were executed in the VL, one of them was isometric load (P1) and two of dynamic load (P2 and P3). SmO2 [%] and Hgb [g/dL] were measured before and after each of these protocols. For P1, three series of 8 s of maximum isometric strength with the rest of 60 s between each set, the average isometric strength (AIS), and the isometric peak strength (IPS) were also recorded. After five minutes, P2 was performed, with an initial load of 40% of AIS. Then, at 30 minutes, P3 was performed considering an initial load of 40% of IPS. Results: The results suggest (I) minimum levels of SmO2 (66.31 ± 9.38%) and Hgb (12.22 ± 0.55 g/dL) during P2, (II) no significant differences were observed between the average loads of the respective protocols for SmO2 and (III) muscle Hgb differed significantly between rest with P1 and P3. Conclusions: Exercises of increasing intensity and of short duration do not significantly modify SmO2. However, Hgb increases substantially compared baseline values.
Czasopismo
Rocznik
Tom
Strony
37--45
Opis fizyczny
Bibliogr. 38 poz., tab., rys., wykr.
Twórcy
autor
- Department of Physical Education and Sports, Faculty of Sport Sciences. University of Granada, Granada, Spain.
- Exercise and Rehabilitation Sciences Laboratory, School of Physical Therapy, Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago, Chile.
autor
- Department of Physical Education and Sports, Faculty of Sport Sciences. University of Granada, Granada, Spain.
autor
- Department of Nursing, Physiotherapy and Occupational Therapy, Faculty of Nursing, Group of Preventive Activities in the University Health Sciences Setting, University of Castilla-La Mancha (Universidad de Castilla-La Mancha/UCLM), Albacete, Spain.
autor
- Department of Physical Education and Sports, Faculty of Sport Sciences. University of Granada, Granada, Spain.
- Department of Physical education, Sports and Recreation, Universidad de La Frontera, Temuco, Chile.
autor
- Department of Physical Education and Sports, Faculty of Sport Sciences. University of Granada, Granada, Spain.
autor
- Disciplinary Department of Kinesiology, Faculty of Health Science, Universidad de Playa Ancha, Valparaíso, Chile.
- Exercise and Rehabilitation Sciences Laboratory, School of Physical Therapy, Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago, Chile.
autor
- Department of Physical Education and Sports, Faculty of Sport Sciences. University of Granada, Granada, Spain.
- Exercise and Rehabilitation Sciences Laboratory, School of Physical Therapy, Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago, Chile.
Bibliografia
- [1] ALVARES T.S., OLIVEIRA G.V. DE, SOARES R., MURIAS J.M., Near-infrared spectroscopy-derived total hemoglobin as an indicator of changes in muscle blood flow during exerciseinduced hyperemia, Journal of Sports Sciences, 2020, 38, 751–758.
- [2] BAILEY C.A., YOON S.H., CÔTÉ J.N., Relative variability in muscle activation amplitude, muscle oxygenation and muscle thickness: Changes with dynamic low-load elbow flexion fatigue and relationships in young and older females, Journal of Electromyography and Kinesiology, 2021, 59.
- [3] BARSTOW T.J., Understanding near infrared spectroscopy and its application to skeletal muscle research, Journal of Applied Physiology, 2019, 126, 1360–1376.
- [4] BELARDINELLI R., BARSTOW T.J., PORSZASZ J., WASSERMAN K., Changes in skeletal muscle oxygenation during incremental exercise measured with near infrared spectroscopy. / Modifications de l ’ oxygenation du muscle squelettique lors d ’ un exercice progressif, mesurees par spectroscopie infrarouge, European Journal of Applied Physiology and Occupational Physiology, 1995, 70, 487–492.
- [5] CALAINE INGLIS E., IANNETTA D., MURIAS J.M., The plateau in the NIRS-derived [HHb] signal near the end of a ramp incremental test does not indicate the upper limit of O2 extraction in the vastus lateralis, American Journal of Physiology – Regulatory Integrative and Comparative Physiology, 2017, 313, R723–R729.
- [6] COHEN J., Statistical power analysis for the behavioral sciences, 2nd ed., Hillsdale, Lawrence Earlbaum Associates, N.J., 1988.
- [7] CRUM E.M., O’CONNOR W.J., VAN LOO L., VALCKX M., STANNARD S.R., Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise, European Journal of Sport Science, 2017, 17, 1037–1043.
- [8] DAVIS P.R., YAKEL J.P., ANDERSON D.J.F., Muscle oxygen demands of the vastus lateralis in back and front squats, International Journal of Exercise Science, 2020, 13, 734–743.
- [9] FARZAM P., STARKWEATHER Z., FRANCESCHINI M.A., Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle, Physiological Reports, 2018, 6, 1–14.
- [10] FELDMANN A., SCHMITZ R., ERLACHER D., Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor, Journal of Biomedical Optics, 2019, 24, 1.
- [11] FERRARI M., MOTTOLA L., QUARESIMA V., Principles, Techniques, and Limitations of Near Infrared Spectroscopy, 2004, 463–487.
- [12] GÓMEZ-CARMONA C.D., BASTIDA-CASTILLO A., ROJAS-VALVERDE D., DE LA CRUZ SÁNCHEZ E., GARCÍA-RUBIO J., IBÁÑEZ S.J, et al., Lower-limb Dynamics of Muscle Oxygen Saturation During the Back-squat Exercise: Effects of Training Load and Effort Level, Journal of Strength and Conditioning Research, 2020, 34, 1227–1236.
- [13] GUAN S., LIN N., YIN Y., LIU H., LIU L., QI L., The effects of inter-set recovery time on explosive power, electromyography activity and tissue oxygenation during plyometric training, Sensors, 2021, 21, 3015.
- [14] HAMMER S.M., ALEXANDER A.M., DIDIER K.D., HUCKABY L.M., BARSTOW T.J., Limb blood flow and muscle oxygenation responses during handgrip exercise above vs. below critical force, Microvascular Research, 2020, 131, 104002.
- [15] HARGREAVES M., SPRIET L.L., Skeletal muscle energy metabolism during exercise, Nature Metabolism 1–12, 2020.
- [16] HEARON C.M., DINENNO F.A., Regulation of skeletal muscle blood flow during exercise in ageing humans, Journal of Physiology, 2016, 594, 2261–2273.
- [17] HOPKER J.G., O’GRADY C., PAGEAUX B., Prolonged constant load cycling exercise is associated with reduced gross efficiency and increased muscle oxygen uptake, Scandinavian Journal of Medicine and Science in Sports, 2017, 27, 408–417.
- [18] HUG F., LAPLAUD D., LUCIA A., GRELOT L., EMG threshold determination in eight lower limb muscles during cycling exercise: A pilot study, International Journal of Sports Medicine, 2006, 27, 456–462.
- [19] JAÉN-CARRILLO D., ROCHE-SERUENDO L.E., CARTÓN-LLORENTE A., GARCÍA-PINILLOS F., Agreement between muscle oxygen saturation from two commercially available systems in endurance running: Moxy Monitor versus Humon Hex, Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology, 2021, 175433712110157.
- [20] KELLAWAN J.M., BENTLEY R.F., BRAVO M.F., MOYNES J.S., TSCHAKOVSKY M.E., Does oxygen delivery explain interindividual variation in forearm critical impulse?, Physiological Reports, 2014, 2.
- [21] KIRBY B.S., CLARK D.A., BRADLEY E.M., WILKINS B.W., The Balance of Muscle Oxygen Supply and Demand Reveals Critical Metabolic Rate and Predicts Time to Exhaustion, Journal of Applied Physiology, japplphysiol.00058.2021, 2021.
- [22] LUCERO A.A., ADDAE G., LAWRENCE W., NEWAY B., CREDEUR D.P., FAULKNER J. et al., Reliability of muscle blood flow and oxygen consumption response from exercise using near-infrared spectroscopy, Experimental Physiology, 2018, 103, 90–100.
- [23] MANCINI D.M., BOLINGER L., LI H., KENDRICK K., CHANCE B., WILSON J.R., Validation of near-infrared spectroscopy in humans, Journal of Applied Physiology, 1994, 77, 2740–2747.
- [24] MANIMMANAKORN N., ROSS J.J., MANIMMANAKORN A., LUCAS S.J., HAMLIN M.J., Effect of whole-body vibration therapy on performance recovery, International journal of Sports Physiology and Performance, 2015, 10, 388–395.
- [25] MARTINEZ-GARCIA D., RODRIGUEZ-PEREA A., BARBOZA P., ULLOA-DÍAZ D., JEREZ-MAYORGA D., CHIROSA I. et al., Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity, PeerJ, 2020, 8, e9951.
- [26] MEAD A.C., MCGLYNN M.L., SLIVKA D.R., Acute effects of functional dry needling on skeletal muscle function, Journal of Bodywork and Movement Therapies, 2021, 26, 123–127.
- [27] MIRANDA-FUENTES C., CHIROSA-RÍOS L.J., GUISADO-REQUENA I.M., DELGADO-FLOODY P., JEREZ-MAYORGA D., Changes in muscle oxygen saturation measured using wireless near-infrared spectroscopy in resistance training: A systematic review, International Journal of Environmental Research and Public Health, 2021, 18.
- [28] MIRANDA-FUENTES C., GUISADO-REQUENA I.M., DELGADO-FLOODY P., ARIAS-POBLETE L., PÉREZ-CASTILLA A., JEREZ-MAYORGA D. et al., Reliability of low-cost near-infrared spectroscopy in the determination of muscular oxygen saturation and hemoglobin concentration during rest, isometric and dynamic strength activity, International Journal of Environmental Research and Public Health, 2020, 17, 1–14.
- [29] MYERS C., Muscle Oxygenation Applications to Endurance Training, Iris Publishers, 2020.
- [30] PARADIS-DESCHÊNES P., JOANISSE D.R., BILLAUT F., Sex-specific impact of ischemic preconditioning on tissue oxygenation and maximal concentric force, Frontiers in Physiology, 2017, 7.
- [31] PEIKON E., The Future is NIRS: Muscle Oxygen Saturation as an Estimation of The Power-Duration Relationship, Anat. and Physiol. Open Access J., 2020, 1.
- [32] PERREY S., FERRARI M., Muscle Oximetry in Sports Science: A Systematic Review, Sports Medicine (Auckland, NZ), 2018, 48, 597–616.
- [33] POOLE D.C., RICHARDSON R.S., Determinants of oxygen uptake: Implications for exercise testing, Sports Medicine, 1997, 24, 308–320.
- [34] RODRIGUEZ-PEREA Á., JEREZ-MAYORGA D., GARCÍA-RAMOS A., MARTÍNEZ-GARCÍA D., CHIROSA RÍOS L.J., Reliability and con current validity of a functional electromechanical dynamometer device for the assessment of movement velocity, Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology 175433712098488, 2021.
- [35] RODRIGUEZ-PEREA A., RÍOS L.J.C., MARTINEZ-GARCIA D., ULLOA-DÍAZ D., ROJAS F.G., JEREZ-MAYORGA D. et al., Reliability of isometric and isokinetic trunk flexor strength using a functional electromechanical dynamometer, PeerJ, 2019.
- [36] STONE K.J., FRYER S.M., RYAN T., STONER L., The validity and reliability of continuous-wave near-infrared spectroscopy for the assessment of leg blood volume during an orthostatic challenge, Atherosclerosis, 2016, 251, 234–239.
- [37] STRINGER W., WASSERMAN K., CASABURI R., PORSZASZ J., MAEHARA K., FRENCH W., Lactic acidosis as a facilitator of oxyhemoglobin dissociation during exercise, Journal of Applied Physiology, 1994, 76, 1462–1467.
- [38] THORNTON H.R., DASCOMBE B., Developing Athlete Monitoring Systems in Team Sports: Data Analysis and Visualization, International Journal of Sports Physiology and Performance, 2019.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-be892b19-4715-4555-9f7e-809d7f970c3b