PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
Tytuł artykułu

Measurement method of the LV network for the PLC PRIME transmission and its application

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Metoda badania sieci LV do transmisji PLC PRIME
Języki publikacji
EN
Abstrakty
EN
The indirect method is proposed for the assessment of the susceptibility of LV network for PLC PRIME transmission. The method depends on determining the value of PER and FER estimator under different transmission conditions then the appropriate interpretation of PER and FER with regards to services for which PRIME interface has been developed. The proposed method was verified in real telemetric network for automatic electricity meters reading. The paper presents also selected implementation issues of the method and application notes.
PL
Ocena sieci nN dokonywana jest metodą pośrednią, polegającą na pomiarze wartości PER i estymatora wartości FER. Zaproponowano, odpowiednie metody interpretacji wyników pozwalające na wymierną ocenę oraz prognozowanie jakości transmisji w standardzie PLC PRIME w sieci nN. Proponowane metody zostały zweryfikowane w rzeczywistej sieci telemetrycznej przeznaczonej do odczytu liczników energii elektrycznej. W pracy również przedstawiono wybrane zagadnienia implementacyjne oraz ogólny opis aplikacji pomiarowej.
Rocznik
Strony
99--103
Opis fizyczny
Bibliogr. 11 poz., schem., tab., wykr.
Twórcy
  • Uniwersytet TechnologicznoPrzyrodniczy, Instytut Telekomunikacji i Informatyki, ul. Kaliskiego 7, 85-789 Bydgoszcz
Bibliografia
  • [1] ITU-T Recommendation G.9904 (10/2012), Narrowband orthogonal frequency division multiplexing power line communication transceivers for PRIME networks, (2013)
  • [2] Mlynek P., Misurec J. and Koutny M., Modeling and evaluation of power line for Smart grid communication, Przegląd Elektrotechniczny, 87 (2011), nr.8, 228-232
  • [3] Zimmermann M. and Dostert K., Analysis and Modeling of Impulsive Noise in Broad-Band Powerline Communications, IEEE Trans. on Electromagnetic, 44 (2002), n.1, 377-386
  • [4] Matanza J., Alexandres. S. and Rodriguez-Morcillo C., PRIME Performance Under Impulsive Noise Environments, 2012 IEEE International Symposium on Power Line Communications and Its Applications, (2012), 380-385
  • [5] Meng H., Guan Y. L., and Chen S., Modeling and Analysis of Noise Effects on Broadband Power-Line Communications, IEEE Trans. on Power Delivery, 20 (2005), n.2, 630-637
  • [6] Kikkert C. J., An On-line PLC Frequency Impedance Analyzer, 2013 IEEE International Conference on Smart Grid Communications (SmartGridComm), (2013), 606-611
  • [7] Golomb S.W., Shift Registers Sequences, Holden-Day, San Francisco (1967)
  • [8] Antoniali M., and Tonello A. M., Measurement and Characterization of Load Impedances in Home Power Line Grids, IEEE Trans. on Instrumentation and Measurement, 63 (2014), n.3, 548-556
  • [9] MacWilliams F.J., and Sloane N.J.A., Pseudo-Random Sequences and Arrays, Proceedings of the IEEE, 64 (1976), n.12, 1715-1729
  • [10] Kiedrowski P., Media Independent Protocol Suite for Energy Management Systems Based on Short Range Devices, Prace Instytutu Elektrotechniki, LIX (2012), n.258, 189-199
  • [11] ITU-T Recommendation G.821 (11/1988), Error performance of an international digital connection forming part of an integrated services digital network, (1989)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-bdfc4a04-2868-401b-bedd-1f5def776fce
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.