A new approach to test set for SAW delay line based gas sensors

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper presents a new switchable test set dedicated to dual delay line surface acoustic wave (SAW) gas sensors. It operates at frequency of 205 MHz utilizing dual delay line fabricated by SAW Components. The sensor detects traces of dimethyl methylphosphonate (DMMP) that is a simulant of combat poisoning agents. The test set described is built of a single oscillator adopting commutation of two SAW delay lines and this way has better thermal properties than commonly used networks consisting of two independent oscillators. Its measured frequency to temperature is ten times lower than obserwed for double oscillator networks. Additonaly due to alteranate operation of the sensors the interaction between delay lines built on common substrate is eliminated. This work was presented at the 53th Winter School on Wave and Quantum Acoustics [1] February, 24 - 27, 2025, DOI 10.5162/20WWonAE/A7.
Twórcy
  • Silesian University of Technology, Gliwice, Poland
  • Silesian University of Technology, Gliwice, Poland
  • Silesian University of Technology, Gliwice, Poland
Bibliografia
  • [1] J. Wrotniak, M. Magnuski, W. Jakubik “An Improved Test Set with Switchable Oscillator for Dual-delay Line SAW Gas Sensors”, Proceedings of 53th Winter School on Wave and Quantum Acoustics (WSW&QA), Szczyrk, Beskidy Mountains, POLAND, February, 24 - 27, 2025, DOI 10.5162/20WWonAE/A7
  • [2] M.Z. Aslam, H. Zhang, V.S. Sreejith, M. Naghdi, S. Ju, “Advances in the surface acoustic wave sensors for industrial applications: Potentials, challenges, and future directions: A review”, Measurement Volume 222, 30 November 2023. https://doi.org/10.1016/j.measurement.2023.113657
  • [3] G. Fawaz, FE. Dbibih, M. Vanotti, V. Soumann, V. Blondeau-Patissier ”Innovative surface acoustic wave devices: A solution for real time monitoring and self-cleaning cascade impactor”, Measurement, Volume 240, 30 January 2025. https://doi.org/10.1016/j.measurement.2024.115652
  • [4] S. Liu, D. Wang, R. Xing, J. Ren, W. Lu, “Research on error correction model of surface acoustic wave yarn tension transducer based on DOA-SVR model”, Measurement Volume 226, 28 February 2024, 114126. https://doi.org/10.1016/j.measurement.2024.114126
  • [5] Y. Li, J. Li, J. Huang, H. Zhou, “Fitting analysis and research of measured data of SAW micro-pressure sensor based on BP neural network,” Measurement, Volume 155, April 2020, 107533. https://doi.org/10.1016/j.measurement.2020.107533
  • [6] Y. Li, W. Lu, Ch. Zhu, Q. Liu, H. Zhang, B. Lei, “Finite element analysis of surface acoustic wave based on a micro force sensor”, Measurement, Volume 65, April 2015, Pages 112-119. https://doi.org/10.1016/j.measurement.2014.12.053
  • [7] L. Chybowski, P. Kowalak, M. Szczepanek, P. Jóźwiak, P. Danisiewicz, “The assessment of surface acoustic wave sensing for testing fuel dilution of lubricating oils”, Measurement, Volume 231, 31 May 2024, 114589. https://doi.org/10.1016/j.measurement.2024.114589
  • [8] W. Lu, Ch. Zhu, J. Zhang, Ch. Shi, X. zhou Lü, “Study of small size wavelet transform processor and wavelet inverse-transform processor using SAW devices”, Measurement Volume 44, Issue 5, June 2011, Pages 994-999 https://doi.org/10.1016/j.measurement.2011.02.007
  • [9] W. Jakubik, J. Wrotniak, A. Kaźmierczak-Bałata, A. Stolarczyk, P. Powroźnik, “Light-activated SAW sensor structures with photoconductive polymer films for DMMP detection”, Sensors and Actuators B - Chemical, 2023, vol. 384, s.1-15. https://doi.org/10.1016/j.snb.2023.133597
  • [10] G. F. Fine, L. M. Cavanagh, A. Afonja, R. Binions, ”Metal oxide semi-conductor gas sensors in environmental monitoring”, Sensors 2010, 10, 5469-5502. https://doi.org/10.3390/s100605469
  • [11] C. Wei, L. Dai, A. Roy, T.B. Tolle, “Multifunctional chemical vapor sensors of aligned carbon nanotube and polymer composites”, J. Am. Chem. Soc. 2006, 128, 1412-1413.
  • [12] S. Subrahmanyam, S.A. Piletsky, A.P. Turner, “Application of natural receptors in sensors and assays”, Analytical Chemistry. 2002, 74, 3942-3951. https://doi.org/10.1021/ac025673
  • [13] C. Caliendo, P. Verardi, E. Verona, A. D’Amico, C. Di Natale, G. Saggio, M. Serafini, R. Paolesse, S. Huq, “Advances in SAW-based gas sensors”, Smart Mater. Struct. 1997, 6, 689.
  • [14] K. Mitzner, E. Berkenpas, J. Sternhagen, M. Karlgaard, C. Wold, D. Galipeau, “A direct digital synthesis system for surface acoustic wave sensors”, Proceedings of the 2001 IEEE International Frequency Control Symposium and PDA Exhibition, 6-8.06.2001, 449-453. https://doi.org/10.1109/FREQ.2001.956271
  • [15] M. Rapp, J. Reibel, A. Voight, M. Balzer, O. Bülow, “New miniaturized SAW-sensor array for organic gas detection driven by multiplexed oscillators”, Sens. Act. B 64 (2000) 169-172. https://doi.org/10.1016/S0925-4005(99)00321-4
  • [16] W. Wen, H. Shitang, L. Shunzhou, L. Minghua, P. Yong, “Enhanced sensitivity of SAW gas sensor coated molecularly imprinted polymer incorporating high frequency stability oscillator”, Sens. Act. B 125 (2007), 422-427. https://doi.org/10.1016/j.snb.2007.02.037
  • [17] D. Matatagui, J. Martí, M. J. Fernández, J. L. Fontecha, J. Gutiérrez, I. Gràcia, C. Cané, M. C Horrillo, “Chemical warfare agents simulants detection with an optimized SAW sensor array”, Sens. Act. B 154 (2011), 199-205. https://doi.org/10.1016/j.snb.2010.01.057
  • [18] H. Ch. Ou, M. Zaghloul, “The SAW Resonators on LiNbO3 for Mass-Sensing Applications”, Proceedings of 2010 IEEE International Symposium on Circuits and Systems, 30 May - 2 June 2010. https://doi.org/10.1109/ISCAS.2010.5537659
  • [19] J. Wrotniak, W. Jakubik, P. Powroźnik, A. Stolarczyk, M. Magnuski, “Akustyczne badania polimeru typu RR -P3HT do wykrywania DMMP w powietrzu”, Przegląd Elektrotechniczny 06/2018 page. 70. https://doi.org/10.15199/48.2018.06.12
  • [20] W. Jakubik, J. Wrotniak, A. Kaźmierczak-Bałata, A. Stolarczyk, P. Powroźnik, “Light-activated SAW sensor structures with photoconductive polymer films for DMMP detection”, Sensors and Actuators B - Chemical, 2023, vol. 384, s.1-15. https://doi.org/10.1016/j.snb.2023.133597
  • [21] W. Jakubik, J. Wrotniak, P. Powroźnik, “Theoretical analysis of a surface acoustic wave gas sensor mechanism using electrical conductive bi-layer nanostructures”, Sensors and Actuators B - Chemical, 2018, vol. 262, s.947-952. https://doi.org/10.1016/j.snb.2018.02.106
  • [22] T. Hejczyk, J. Wrotniak, W. Jakubik, “Numerical analysis of the steady state in SAW sensor structures with selected polymers for detection of DMMP and CO”, W: Metal-oxide gas sensors, IntechOpen 2023, s.69-89, https://doi.org/10.5772/intechopen.109367
  • [23] T. Hejczyk, J. Wrotniak, M. Magnuski, W. Jakubik, “Experimental and numerical acoustoelectric investigation of the new SAW structure with (RR)-P3HT polymer in DMMP detection”, Archives of Acoustics, 2021, vol. 46, nr 2, s.313-322.
  • [24] E. Charles Free and S. Colin Aitchison, “RF and Microwave Circuit Design: Theory and Applications”, Wiley 2021
  • [25] A. Grebennikov, “RF and Microwave Transistor Oscillator Design”, ISBN-13: 9780470512081,30. April 2007 https://doi.org/10.1002/9780470512098
  • [26] H. W. Thim, “Temperature Effects in Bulk GaAs Amplifiers”, IEEE Transactions on Electron Devices, 1967, VOL.14, NO. 2. https://doi.org/10.1109/T-ED.1967.15899
  • [27] A. Plesca, “Thermal Analysis of Power Semiconductor Converters”, Gheorghe Asachi Technical University of Iasi, 2011. SBN 978-953-307-335-4
  • [28] Y. Avenas, L. Dupont, Z. Khatir, “Temperature Measurement of Power Semi- conductor Devices by Thermo-Sensitive Electrical Parameters - A Review”, IEEE Transactions on Power Electronics, 2012, p.3081-3092. https://doi.org/10.1109/TPEL.2011.2178433
  • [29] K. Górecki, J. Zarębski, P. Górecki, P. Ptak, “Compact Thermal Models of Semiconductor Devices - a Review”, INTL Journal of Electronics and Telecommunications, 2019, VOL. 65, NO.2, PP. 151-158. https://doi.org/10.24425/ijet.2019.126295
Uwagi
This work was supported by “BK - Directional Research Silesian University of Technology” (Faculty of Automatic Control, Electronics and Computer Science, Department of Digital Systems). Based on this, the described system has been patented no. PL 230526.