PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Switching losses in three-phase voltage source inverters

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Straty przełączania w trójfazowych falownikach napięcia
Języki publikacji
EN
Abstrakty
EN
The efficiency of three-phase voltage source inverters depends mainly on power losses that occur in semi-conductor elements. Total losses in these elements are a sum of conduction losses and switching losses. The switching losses are dependent on the supply voltage, load current, operating frequency and on the dynamic parameters of the switching elements; these losses can be limited with the use of soft switching methods. This paper discusses the switching loss dependence on the above mentioned factors. An analysis was carried out on power losses in voltage source inverters which generate the output voltage in the form of a rectangular wave and losses in these inverters operating with pulse width modulation. A comparison of switching losses was performed for two voltage source inverters with different nominal power ratings.
PL
Sprawność trójfazowch falowników napięcia zależy głównie od strat mocy występujących w elementach półprzewodnikowych. Straty w tych elementach są sumą strat przewodzenia i strat przełączania. Straty przełączania zależą od napięcia zasilania, prądu odbiornika, częstotliwości pracy oraz od parametrów dynamicznych tranzystorów IGBT; straty te mogą być ograniczone przez zastosowanie układów wspomagających przełączanie elementów. W artykule omówiono zależność strat przełączania od wymienionych czynników. Przeprowadzono analizę strat w falowniku generującym na wyjściu napięcie w postaci fali prostokątnej oraz analizę strat przełączania w falowniku pracującym z modulacją szerokości impulsów. Porównania strat przełączania dokonano dla dwóch falowników napięcia o różnych mocach znamionowych.
Rocznik
Strony
47--60
Opis fizyczny
Bibliogr. 14 poz., wz., rys., tab., wykr.
Twórcy
autor
  • Institute of Electromechanical Energy Conversion, Faculty of Electrical and Computer Engineering, Cracow University of Technology
autor
  • Institute of Electromechanical Energy Conversion, Faculty of Electrical and Computer Engineering, Cracow University of Technology
autor
  • Institute of Electromechanical Energy Conversion, Faculty of Electrical and Computer Engineering, Cracow University of Technology
Bibliografia
  • [1] Feix G., Dieckerhoff S., Allmeling J., Schonberger J., Simple Methods to Calculate IGBT and Diode Conduction and Switching Losses, 13th European Conference on Power Electronics and Applications, EPE, Barcelona, Spain, 8–10 September, 2009, 1-8.
  • [2] Drofenik U., Kolar J.W., A General Scheme for Calculating Switching- and Conduction-Losses of Power Semiconductors in Numerical Circuit Simulations of Power Electronic Systems, 5th International Power Electronics Conference, IPEC-Niigata, Japan, 2005.
  • [3] Hiraki E., Tanaka T., Nakaoka M., Zero-Voltage and Zero-Current Soft – Switching PWM Inverter, 36th Power Electronics Specialists Conference PESC, Recife, Brazil, 12–16 June, 2005, 798-803.
  • [4] Martinez B., Li R., Ma K., Xu D., Hard Switching and Soft Switching Inverters Efficiency Evaluation, International Conference on Electrical Machines and Systems ICEMS, Wuhan, China, 17–20 October, 2008, 1752-1757.
  • [5] Bernet S., Lüscher M., Steimer P.K., IGCTs in Soft Switching Power Converters, 8th European Conference on Power Electronics and Applications, Lausanne, France, 7–9 September. 1999, 1-11.
  • [6] Jinrong Q., Khan A., Batarseh I., Turn-off Switching Loss Model and Analysis of IGBT under Different Switching Operation Modes, 21st International Conference on Industrial Electronics, Control, and Instrumentation IEEE IECON, Orlando, USA, 6–10 November, 1995, Vol. 1, 240-245.
  • [7] Cavalcanti M.C., da Silva E.R., Boroyevich D., Wei D., A Feasible Loss Model for IGBT in Soft-Switching Inverters, 34th IEEE Power Electronics Specialist Conference, PESC, de Campina Grande, Brazil, 15–19 June, 2003, Vol. 4, 1845-1850.
  • [8] Maswood A.I., A switching loss study in SPWM igbt inverter, 2nd IEEE International Conference on Power and Energy (PECon 08), Johor Baharu, Malaysia, 1–3 December, 2008, 609-613.
  • [9] Rashid M.H., Power electronics handbook, Academic Press, San Diego 2001.
  • [10] Skvarenina T.L., The power electronics handbook, Industrial Electronics Series, CRC Press, Boca Raton 2002.
  • [11] Peng F.Z., Gui-Jia S., Tolbert L.M., A Passive Soft-Switching Snubber for PWM Inverters, IEEE Transactions on Power Electronics, Vol. 19, Issue 2, March 2004, 363-370.
  • [12] Rajapakse A.D., Gole A.M., Wilson P.L., Approximate Loss Formulae for Estimation of IGBT Switching Losses through EMTP-type Simulations, International Conference on Power Systems Transients, IPST, Montreal, Canada, 19–23 June, 2005, Paper No. 184.
  • [13] Mori M., Kobayashi H., Saiki T., Nagasu M., Sakano J., Saitou R., 3.3 kV Punchthrough IGBTwith Low Loss and Fast Switching, IEEE International Symposium on Power Semiconductor Devices and IC’s, ISPSD, Weimar, Germany, 26–29 May, 1997, 229-232.
  • [14] Petterteig A., Lode J., Undeland T.M., IGBT turn-off losses for hard switching and with capacitive snubbers, IEEE Conference of Industry Applications Society Annual Meeting, Dearborn, USA, 28 September–4 October, 1991, Vol. 2, 1501-1507.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-bd98c75d-7e2f-407c-91e9-e59f6865413b
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.