PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Assessment of the state of pedestrian crossing lighting on the basis of field measurements of luminance

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Ocena stanu oświetlenia przejścia dla pieszych na podstawie terenowych pomiarów luminancji
Języki publikacji
EN
Abstrakty
EN
Producing a proper level of contrast of a human figure with the background on pedestrian crossing is an indispensable condition for creating possibilities of noticing a pedestrian by a driver of a vehicle approaching the crossing. The paper presents detailed results of luminance measurements on the pedestrian crossing illuminated by means of three lighting solutions. On the basis of the obtained results of luminance and luminance contrast, effects of lighting of a pedestrian figure have been compared.
PL
Wytworzenie odpowiednio wysokiego poziomu kontrastu sylwetki człowieka z tłem na przejściu dla pieszych jest warunkiem niezbędnym do stworzenia możliwości jej rozpoznania przez kierowcę pojazdu zbliżającego się do przejścia dla pieszych. W artykule zaprezentowano szczegółowe wyniki pomiarów luminancji na oświetlonym za pomocą trzech rozwiązań oświetleniowych przejściu dla pieszych. Na podstawie otrzymanych wyników luminancji i kontrastu luminancji porównano efekty oświetlenia sylwetki pieszego.
Rocznik
Strony
266--269
Opis fizyczny
Bibliogr. 9 poz., il., wykr.
Twórcy
autor
  • Warsaw University of Technology, Faculty of Transport, ul. Koszykowa 75, 00-662 Warsaw
Bibliografia
  • [1] Standard DIN 67523-1/2:2010: Lighting of pedestrian crossings (sign 293 StVO) with additional lighting
  • [2] Tomczuk P., Assessment model of luminance contrast of pedestrian figure against background on pedestrian crossing, Electrical Review, R. 88 NR 3a/2012 p.104-107 SIGMA-NOT
  • [3] Tomczuk, P., Pedestrian safety – luminance measurements on pedestrian crossing, Research papers of Warsaw University of Technology, Transport, Researches on Transport Means and Systems, Research Bulletin no. 80, pp.117-135 Oficyna Wydawnicza Politechniki Warszawskiej, Warsaw 2012
  • [4] Tomczuk P., Formal requirements basis of illuminance parameters concerning pedestrian crossing lighting, Monographs of the Maintenance System Unit, Polish Academy of Sciences, Committee on Machine Building Maintenance, Problems of Maintenance of Sustainable Technological Systems, Volume IV, Automotive Engineering and Vehicle safety Engineering, pp. 165-186, Kielce University of Technology, Kielce 2012
  • [5] Producer of lighting frames Thorn IVS, www.thornlighting.p
  • [6] Producer of lighting frames Calypso Zebra, www.schreder.pl
  • [7] Google digital map
  • [8] Catalogue data LMK Mobile Advanced, www.technoteam.de
  • [9] Producer of lighting frames, www.brilux.pl
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-bcf1edb1-924a-4c06-bcc6-5bfac6f97dfd
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.