Combi-steamer condensation hoods are widely used in modern gastronomy. They condense steam produced by the combi-steamer and also filter solid particles, moisture, grease and smells. All these factors negatively affect the staff and dishes, so efficient work of the condensation hoods becomes important. A mathematical and experimental analysis of such a device is described in this paper. First a measurement methodology was designed and measurements of air humidity, temperature and mass flow rates were performed. The measurement procedure concerned dedicated a steam generator and combi-steamer. Next a mathematical model was developed. It was based on mass and energy balances of the condensation hood. The condensate flow rate turned out to be insufficient to fulfill the energy balance while measured directly. Hence, it was calculated from heater’s power of the steam generator and the balance model was validated. The combisteamer had an unknown output, so the condensate flow rate was provided by the balance model after its validation. A preliminary diagnosis of the device was carried out as well.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
125--149
Opis fizyczny
Bibliogr. 30 poz., rys., tab., wz.
Twórcy
autor
- Silesian University of Technology, Konarskiego 22, 44-100 Gliwice, Poland
autor
- Silesian University of Technology, Konarskiego 22, 44-100 Gliwice, Poland
autor
- Silesian University of Technology, Konarskiego 22, 44-100 Gliwice, Poland
autor
- Silesian University of Technology, Konarskiego 22, 44-100 Gliwice, Poland
autor
- Retech Ltd., Wojska polskiego 6A, 39-300 Mielec, Poland
autor
- Silesian University of Technology, Konarskiego 22, 44-100 Gliwice, Poland
Bibliografia
- [1] Diane Lane: ONE FOR ALL. Caterer & Hotelkeeper, 203(2013), 4799, 56–58
- [2] Henny Penny Corp. Combi cooking. 2007.
- [3] Su J., Sun Z., Zhang D: Numerical analysis of steam condensation over a vertical surface in presence of air. Ann. Nucl. Energy 72(2014), 10, 268–276.
- [4] Fan G., Tong P., Sun Z., Chen Y.: Development of a new empirical correlation for steam condensation rates in the presence of air outside vertical smooth tube. Ann. Nucl. Energy 113(2018), 3, 139–146.
- [5] Noori Rahim Abadi S.M.A., Mehrabi M., Meyer J.P.: Numerical study of steam condensation inside a long, inclined, smooth tube at different saturation temperatures. Int. J. Heat Mass Trans. 126(2018), 11, 15–25.
- [6] Bian H., Sun Z., Cheng X., Zhang N., Meng Z., Ding M.: CFD evaluations on bundle effects for steam condensation in the presence of air under natural convection conditions. In. Commun. Heat. Mass 98(2018),11, 200–208.
- [7] O’Donovan A., Grimes R.: Pressure drop analysis of steam condensation in aircooled circular tube bundles. Appl. Therm. Eng. 87(2015), 8, 106–116.
- [8] Tarasov G.I., Bol’shukhin M.A., Sinitsyn A.N., VasyatkinA. G., Kustov S.V.: Experimental studies of heat transfer during steam condensation on a vertical multirow on-line bundle of slightly inclined coil tubes with and without noncondensable gas in the bundle. Therm. Eng. 59(2012), 1, 26–32.
- [9] Fan G., Tong P., Sun Z., Chen Y.: Experimental study of pure steam and steam– air condensation over a vertical corrugated tube. Prog. Nucl. Energ. 109(2018), 11, 239–249.
- [10] Wais P.: Fluid flow consideration in fin-tube heat exchanger optimization. Arch. Thermodyn. 31(2010), 3, 87–104.
- [11] Tian L., He Y., Tao Y., Tao W.: A comparative study on the air-side performance of wavy fin-and-tube heat exchanger with punched delta winglets in staggered and inline arrangements. Int. J. Therm. Sci. 48(2009), 9, 1765–1776.
- [12] Kennedy I.J., Spence S.W.T., Spratt G.R., Early J.M.: Investigation of heat exchanger inclination in forced-draught air-cooled heat exchangers. Appl. Therm. Eng. 54(2013), 2, 413–421.
- [13] Lee D.H., Jung J.M., Ha J.H., Cho Y.I.: Improvement of heat transfer with perforated circular holes in finned tubes of air-cooled heat exchanger. Int. Commun. Heat Mass 39(2012), 2, 161–166 .
- [14] Kashani A.H.A., Maddahi A., Hajabdollahi H.: Thermal-economic optimization of an air-cooled heat exchanger unit. Appl. Thermal Eng. 54(2013), 1, 43–55.
- [15] Cengel Y.A.: Heat Transfer: A Practical Approach (3rd Edn.). McGraw-Hill, Boston 2007.
- [16] Wang Y., Zhao Q., Zhou Q., Kang Z., Tao W.: Experimental and numerical studies on actual flue gas condensation heat transfer in a left–right symmetric internally finned tube. Int. J. Heat Mass Tran. 64(2013), 9, 10–20.
- [17] Mohapatra K., Mishra D.: Effect of fin and tube configuration on heat transfer of an internally finned tube. Int. J. Numer. Meth. Heat Fluid Fl. 25(2015), 8, 1978– 1999.
- [18] Wang Q.-W., Lin M., Zeng M.: Effect of lateral fin profiles on turbulent flow and heat transfer performance of internally finned tubes. Appl. Therm. Eng. 29(2009), 14-15, 3006–3013.
- [19] Kim D.-K.: Thermal optimization of internally finned tube with variable fin thickness. Appl. Therm. Eng. 102(2016), 6, 1250–1261.
- [20] Huq M., Huq A.M. Aziz-ul, Rahman M.M.: Experimental measurements of heat transfer in an internally finned tube. Int. Commun. Heat Mass 25(1998), 5, 619–630.
- [21] Taler D.: Model matematyczny oraz badania aerodynamiczne i przepływowocieplne chłodnicy samochodowej. Archiwum Motoryzacji 4(2001), 145–162 (in Polish).
- [22] Long Y., Wang S., Wang J., Zhang T.: Mathematical model of heat transfer for a finned tube cross-flow heat exchanger with ice slurry as cooling medium. Procedia Engineer. 146(2016), 1, 513– 522.
- [23] Li B., You S., Ye T., Zhang H., Li X., Li C.: Mathematical modeling and experimental verification of vacuum glazed transpired solar collector with slit-like perforations. Renew. Energ. 69(2014), 9, 43–49.
- [24] El Mansouri A., Hasnaoui M., Amahmid A., Dahani Y.: Transient theoretical model for the assessment of three heat exchanger designs in a large-scale salt gradient solar pond: Energy and exergy analysis. Energ. Convers. Manage. 167(2018), 7, 45–62.
- [25] Klopfenstein R. Jr.: Air velocity and flow measurement using a Pitot tube. ISA Transactions 37(1998), 4, 257–2639.
- [26] Sun Z., Li Z., Zheng J.: Influence of improper installation on measurement performance of Pitot tube. In: Proc. 2009 Int. Conf. on Industrial Mechatronics and Automation. IEEE, 5(2009), 53–56.
- [27] Narasimhan S., Narasimhan S.: Data reconciliation using uncertain models. Int. J. Adv. Eng. Sci. Appl. Math. 4(2012),(1-2), 3–9.
- [28] Mandel D., Abdollahzadeh A., Maquin D., Ragot J.: Data reconciliation by inequality balance equilibration: a LMI approach. Int. J. Miner. Proces. 53(1998),3, 157–169.
- [29] Narasimhan S., Shah S.L.: Model identification and error covariance matrix estimation from noisy data using PCA. Control Eng. Pract. 16(2008), 1, 146–155.