PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Output signal change analysis of an uncooled microbolometer focal plane array with respect to varying control voltages and operating point temperature

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This paper presents results of output signal analysis of uncooled microbolometric focal plane array FPA. The analysis focuses on detectors manufactured by ULIS. The signal has been tested against varying control voltages, it is blind microbolometer biasing VSK and active microbolometer biasing VFID. The working point temperature of the environment was also altered in range from 5°C to 60°C. Such analysis can be used to check the results against current mathematical model of FPA’s behavior and verify validity of the measurement method in varying working conditions. Later it could allow explore possibility to design corrective algorithms.
Słowa kluczowe
Wydawca
Rocznik
Strony
95--98
Opis fizyczny
Bibliogr. 4 poz., rys., tab., wykr., wzory
Twórcy
autor
  • Institute of Optoelectronics, Military University of Technology 2 gen. S. Kaliskiego Str., Warsaw, Poland
autor
  • Institute of Optoelectronics, Military University of Technology 2 gen. S. Kaliskiego Str., Warsaw, Poland
autor
  • Institute of Optoelectronics, Military University of Technology 2 gen. S. Kaliskiego Str., Warsaw, Poland
autor
  • Institute of Optoelectronics, Military University of Technology 2 gen. S. Kaliskiego Str., Warsaw, Poland
  • Institute of Optoelectronics, Military University of Technology 2 gen. S. Kaliskiego Str., Warsaw, Poland
autor
  • Institute of Optoelectronics, Military University of Technology 2 gen. S. Kaliskiego Str., Warsaw, Poland
Bibliografia
  • [1] Bieszczad Grzegorz, Gogler Sławomir, Madura Henryk, Krupiński Michał: Non-uniformity correction with temperature influence compensation in microbolometer detector. SPIE 9481, 948113, doi: 10.1117/12.2184645, 2015.
  • [2] Bieszczad Grzegorz, Sosnowski Tomasz, Madura Henryk, Gogler Sławomir, Krupiński Michał: Non-uniformity correction in microbolometer array with temperature influence compensation. Metrology and Measurement Systems, vol. XXI, nr 4, p. 709–718, 2014.
  • [3] Gerlach Gerald, Budzier Helmut: Thermal Infrared Sensors: Theory, Optimisation and Practice,” WILEY, 2011.
  • [4] Madura Henryk, Bieszczad Grzegorz: Metoda korekcji wpływu temperatury na jakość zobrazowania obserwacyjnych kamer termowizyjnych. Rozprawa doktorska, Warszawa: Wojskowa Akademia Techniczna sygn. 71309/III/A, 2012.
Uwagi
PL
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-b7340fb1-92ef-46be-b740-9243f78cda62
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.